Loading...
HomeMy WebLinkAboutDERR-2025-004595State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieuritncmt Gol'ernor Depa1iment of Environmental Quality Tim Da ,is E.n.:cz1th·e Dirt!c.. /or DIVISIO N or El\V IRON MENTAL RESPONSE AN D REMEDIATION Brent H. Everett Dirr!l'lor May 01, 2025 MIKE BEAUPARLANT RED MESA TRADING CO . INC . 501 AIRPORT DR. SUITE 100 FARMINGTON, NM 87401 RE: Request for Petroleum Storage Tank Records RED MESA EXPRESS #516, located at HWY 262, MONTEZUMA CREEK Facility Identification No. ::,uu0329 Dear MIKE BEAUPARLANT: PST operators are required to ensure that certain tests are conducted for their tank system . Dates highlighted in "Yellow" -tests are due soon. Dates highlighted in "Red" -tests are due and you are out of compliance . Tank ID/Alt ID 1/105-UGTA 2/216-UGTA Description Gasoline-Regular-6000 Gasoline-Premium-6000 3/217-UGTA Diesel-Diesel #2 (U.L.S.)-6000 L TT -Line Tightness Test LLD -Line Leak Detector Overfill -Overfill Device LTT Spill Bucket -----------·----------- LLD Overfill NIA N/A . . . . . . . . . . . . . . . . . . . . . . . . . . N/A N/A N/A N/A • • • • • • • • ■ •••• ............. N/A N/A N/A N/A . . . . . . . . . . . . . ............. N/A N/A Tank or Flex/Pipe CP -Corrosion Tests ATG -Automatic Tank Gauging Tank or Flex ---- Pipe CP N/A ••••••••••• ■ • N/A N/A ............. N/A N/A ............. N/A Sump -Tank Top Sump and applicable Dispenser Sumps ATG __ ,_. ___ , __ Sump Please note that UDC tests are not listed, but are required on your facility's next sump test cycle starting July 1, 2023, if applicable. Also, effective immediately pressure vent valves must be tested every three years for gasoline tanks. Please submit a copy of the required tests to the DERR within 30 days of the date due. If you have any questions please call David Wilson at 801-536-4100. 195 Nor th 1950 We st -Sa l t Lake City. UT Mailing Address: -P.O Box 144840 -Salt Lake City. LT 84114-4840 Telephone (801) 536-4100 -Fax 1801) 359-8853 -T.D.D. (801) 536-4414 1t·11w dL·q.1~ruh.g01· \>1 intc<l on I oon.-;I rc1,,;yclcd paper Patriot Petroleum Solution s 10312™STSE AUTOMATIC TANK GAUGE (ATG) OPERATION INSPECTION Unit: 181 Loveland, Colorado 80537' Facility Name: #516 Montezuma Creek UT owner: Red Mesa Address: US Hwy 262 and Indian Hwy 35 Address: 501 Airport Drive suite 100 City, State, Zip Code: UT City, State, Zip Code: farmington NM Facility I.D. #: 5493 Phone #: 505-564-6813 Testing Company: Patriot Petroleum Solutions Phone#: 435-651-3485 I Date: 04/10/25 This procedure is to determine whether the ATG is operating properly. See PEI/RP1200, Section 8.2 for the inspection procedure. This procedure is applicable to tank level monitor stems that touch the bottom of the tank when in place. Tank Number T1 T2 T3 Product Stored Regular Premium Diesel ATG Brand and Model VR 450plus VR450plus VR450plus 1 . Tank Volume, gallons 6016 6016 6016 2. Tank Diameter, inches 96 96 96 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts Iii Yes □No Iii Yes □No Iii Yes □No □Yes □No replaced? 4. Float moves freely on the stem without binding? Iii Yes □No lil Yes □No ~Yes □No □Yes □No 5 . Does the fuel float level agree with the value Iii Yes □No Iii Yes □No Iii Yes □No □Yes □No programmed into the console? 6. Does the water float level agree with the value Iii Yes □No Iii Yes □No Iii Yes □No □Yes □No programmed into the console? 7. Inch level from bottom of stem when 90% alarm 80 80 80 is triggered. 8. Does inch level at which the overfill alarm acti- vates correspond with value programmed in the Iii Yes □No Iii Yes D No Iii Yes D No □Yes □No gauge? 9. Inch level from the bottom when the water float 2 2 2 first triggers c1n alarm. 10. Does inch level at which the water float alarm activates correspond with value programmed in Iii Yes D No Iii Yes □No Iii Yes O No □Yes □No the gauge? If any answers in Lines 3, 4, 5, or 6 are "No," the system has failed the test. Test Results Iii Pass □Fail lil Pass □Fail lil Pass □ Fail □ Pass □Fail Comments: Tester's Name Luis Ledesma Tester's Signature ____________ _ 2/3/25, 10:06 AM Veeder-Root K ATG Issue Date: August 23, 1999 Revision Date: July 23, 2015 Veeder-Root TLS-300, 350, 350R, 350Plus, 8600 Series (Consoles TLS· 450 and TLS-450PLUS), TLS2, Red Jacket ProMax and ProPlus Certification Leak Threshold Applicability Tank Capacity Waiting Time Test Period Temperature Water Sensor Calibration Comments (Models 8463, 8473, 8493 Magnetostrictive Probes) AUTOMATIC TANK GAUGING METHOD Leak rate of 0.2 gph with PD = 95.6% and PFA = 0.3%. 0.126 gph. A tank system should not be declared tight if the testTesult indicates a loss or gain that equals or exceeds this threshold. Gasoline, diesel, aviation fuel, biodiesel blends B6-B20 meeting ASTM D7467, biodiesel B100 meeting ASTM D6751. Maximum of 30,000 gallons. Tanks less than 95% full may be tested. Minimum product level required is based on tank diameter as follows: 48" dia/min 18"; 64" dia/min 21"; 72" dia/min 24"; 96" dia/min 30"; 126" dia/min 39"; 132" dia/min 39". For other tank diameters, see evaluation report. Minimum of 8 hours between delivery and testing. Minimum of 30 minutes between dispensing and testing. There must be no delivery during waiting time. Minimum of 2 hours. Test data are acquired and recorded by system's computer. Leak rate is calculated from the difference between the first and last data collected. There must be no dispensing or delivery during test. Average for product is determined by probe which contains 5 thermistors. At least two thermistors must be submerged in product during test. Must be used to detect water ingress. Minimum detectable water level in the tank is 0.66 inch for model 8463 and 8493 probe. Minimum detectable water level in the tank is 0.75 inch for model 8473 probe. Minimum detectable water level in the tank is 0.38 inch when using TLS 350 with model 8463 probe with 88610x-0x0 water float and software version 30B or higher, or 8600 series with software version 3A or higher. Minimum detectable change in water level is 0.005 inch. Minimum detectable change in water level in tank is 0.01 inch when using TLS 350 with model 8463 probe with 88610x-0x0 water float and software version 30B or higher, or 8600 series with software version 3A or higher. Thermistors and probe must be checked and, if necessary, calibrated in accordance with manufacturer's instructions. Not evaluated using manifolded tank systems. Therefore, this certification is only applicable when there is a probe used in each tank and the siphon is broken during testing. Tests only portion of tank containing product. As product level is lowered, leak rate in a leaking tank decreases (due to lower head pressure). Consistent testing at low levels could allow a leak to remain undetected. EPA leak detection regulations require testing of the portion of the tank which routinely contains product. https://neiwpcc.org/nwglde-files/evals/veeder_root_k.html 1/2