Loading...
HomeMy WebLinkAboutDDW-2025-005469Sanitary Survey - Deficiency Report PWS Number:UTAH26053 Deficiency Points:65 Survey Date:06/13/2025 Survey Name:RIVERS EDGE AT DEER PARK Surveyor:Chris Bowles Sanitary Survey Category: SO SDWIS Severity Code: Significant Deficiency Management and Operations | DS001 | UTAH26053 DISTRIBUTION SYSTEM 27C. The interconnection has been approved by DDW. Rule: R309-550-9(3)Interconnections between different drinking water systems must be reviewed and approved by the Director. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Currently in Approval Process Deficiency Points: 50 Days until points become effective on IPS: 120 SDWIS Deficiency Description: M025 UNAPPROVED INTERCONNECTION WITH ANOTHER WATER SYSTEM Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Management and Operations | DS001 | UTAH26053 DISTRIBUTION SYSTEM 29A. System lacks required storage capacity due to fire demand Rule: R309-510-8(1)(b)Rule requires a public water system to provide equalization storage volume (to meet average day demands for indoor and irrigation water use), fire flow storage volume (if equipped with fire hydrants for fire suppression or required by the local fire code official), and emergency storage (if deemed appropriate by the water system or the Director). Notes:System is supplied by 6" water main from Well and Tank, with 2 commercial buildings 60 Cabins/yurts and 50 camp site connections. There are 3 Fire Hydrants. Looking at the capacity calculation there isn't enough Fire storage to supply 1000 gallons per minute for 1 hour until they get the Consecutive connection with Jordanelle SSD approved. They are currently connected to the JSSD until the well casing is repaired, and returned to service. Irrigation on the property is pumped from run-off collection ponds and shallow wells, with two Secondary water tanks. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: VF34 SYSTEM LACKS REQUIRED STORAGE CAPACITY DUE TO FIRE DEMAND BUT HAS SOP FOR FOLLOWING FIRE INCIDENT Sanitary Survey Category: SM SDWIS Severity Code: Recommendation Management and Operations | DS001 | UTAH26053 DISTRIBUTION SYSTEM 31. Does your water system have an Emergency Response Plan? Rule: R309-105-18 All suppliers are advised to develop contingency plans to cope with possible emergency situations. In many areas of the state the possibility of earthquake damage shall be realistically considered. Notes: Deficiency Points: 0 Days until points become effective on IPS: 0 SDWIS Deficiency Description: M001 NO CURRENT EMERGENCY RESPONSE PROGRAM