Loading...
HomeMy WebLinkAboutDERR-2024-005781195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-139-24 April 9, 2024 Vance Nielson JVP, Inc. P.O. Box 27 Bluff, Utah 84512 Re: Notice of Approval to Remove Delivery Prohibition Tag K & C Trading Post (Sinclair), located at 161 East Main Street, Bluff, Utah Facility Identification No. 5000084 Dear Mr. Nielson: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to issue the attached certificate of compliance for the 10,000 unleaded/5,000 premium compartmented tank at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(6). Please remove and discard any tags that were attached to the fill for these tanks during installation. If you have additional questions, please contact the DERR project manager identified on the red tag at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/RTS/ss Enclosure: Certificate of Compliance cc: Grant Sunada, PhD, Executive Director, San Juan Public Health Department Russell Seeley, District Engineer, Utah Department of Environmental Quality 2024 UST CERTIFICATE OF COMPLIANCE ISSUED TO: LOCATION OF TANKS: JVP INC PO BOX27 BLUFF, UT 84512 K & C TRADING POST (SINCLAIR) 161 Main St. BLUFF UT 84512 Facility ID: 5000084 Tank# Capacity Substance Desc Compliance Financial Assurance Mechanism SA SB 10000 5000 Gasoline Gasoline Yes PST Fund Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY Underground Storage Tank Inspection Verification Form OwnerName: JVPINC Owner Address: PO BOX 27 BLUFF, UT 84512 Operator A: IAN NIELSON/ (435) 672-2221 / 1/1/2027 Facility ID: 5000084 Facility Name: K & C TRADING POST (SINCLAIR) Street Address: 161 Main St. BLUFF, UT 84512 Operator B: IAN NIELSON/ (435) 672-2221 / 1/1/2027 Owner Email: kandcstore@live.com UTM Coordinates X/Y: 627741 / 4127224 -----------------------------------------------------Disp ID/Alt Substance UDC Pipe Flex Loe Install Date UDC Install Date Fire Sat UDC Test Disp Flex CP ID Valve Present Test 3 -1/2 Gasoline Yes Direct Flex Piping in Sump no Steel Flex 03/19/2024 03/19/2024 Yes No 3/19/2024 4 -3/4 Gasoline Yes Direct Flex Piping in 03/19/2024 03/19/2024 Yes No 3/19/2024 Sump no Steel Flex -----------------------------------------------------Tank ID/Alt ID: 5 / 5A EGen/AST/Stat No/ No/ No Pipe Material-Mod: Flexible Plastic -Double-Walled Siphon/Compart: No/ Yes PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 3/13/2024 / 10000 / East Substance Stored: Gasoline/ Regular Two point Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root I TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 4/3/2024 LTTTest: Tank ID/Alt ID: 6 / 58 Siphon/Compart: No/ Yes LLD Test: 04/03/2024 EGen/AST/Stat No/ No/ No PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 3/13/2024 / 5000 I West Substance Stored: Gasoline/ Premium Two point Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root I TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 4/3/2024 LTTTest: LLD Test: 04/03/2024 4/8/2024 Page 1 of 1 Pipe Type/STP Cont: Pressurized/ Yes STP Flex Connectors: Steel Flex in Sump LLD Model: Red Jacket/ VR FX1V Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Overfill alarm / No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / Interstitial DW / ALD STP Sump Test: 03/19/2024 Spill Bk Test: Overfill Test: 4/3/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized/ Yes STP Flex Connectors: Steel Flex in Sump LLD Model: Red Jacket/ VR FX1V Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Overfill alarm / No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / Interstitial DW / ALD STP Sump Test: 03/19/2024 Spill Bk Test: Overfill Test: 4/3/2024 CP Tank Test: CP Pipe Test: