Loading...
HomeMy WebLinkAboutDERR-2025-004466Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name SOLITUDE MOUNTAIN SKI AREA LLC Address 12000 E. COTTONWOOD CANYON SALT LAKE CITY, UT 84121 Contact SOLITUDE MOUNTAIN SKI AREA LLC Phone Email m.johnson@solitudemountain.com TANK LOCATION Name SOLITUDE MOUNTAIN SKI AREA, VEHICAL MAINTENANCE SHOP Address 12000 BIG COTTONWOOD CANYON SALT LAKE CITY, UT 84121 A Operator Michael (MJ) L. Johnson Phone (801) 536-5739 B Operator SAME Phone SAME Facility ID: 4001332 Inspection Date: 06/05/2025 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - lower Gas/Diesel No Steel Swing Galvanic CP None None Yes No None July 28, 2022 2 - upper Diesel No Steel Swing Galvanic CP None None Yes No None July 28, 2022 TANK DETAILS Tank ID/Alt ID 4 / 4 E-Gen/AST No / No Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc May 1, 1989 / 8000 / Single Substance Stored Diesel / Off-road Diesel Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG Veeder Root / TLS-350 LTT Test Sept. 19, 2024 LLD Test Nov. 13, 2024 Pipe Material- Mod Galvanized Steel / Cathodically Protected Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model Red Jacket / VR FX1DV Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankATG PipeAutoLineLeakDetection / PipeLineTightness CP Tank Test July 28, 2022 CP Pipe Test July 28, 2022 Tank ID/Alt ID 7 / 7 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Aug. 1, 2005 / 2000 / Substance Stored Gasoline / Regular Tank Material- Mod Asphalt Coated or Bare Steel- None ATG Veeder Root / TLS-350 LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Bare Steel Flex LLD Model Red Jacket / VR FX1V Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS 2025-06-05 Page 1 of 5 None 2025-06-05 Page 2 of 5 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?Yes Is the site unmanned?No C Operators trained?Yes Cathodic Protection The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank has an overfill device?Yes Tank 4 ATG/IM ATG/IM - Records on site document that the system is properly installed, calibrated, operated, and maintained (system and tank setup reports, maintenance records)? Written documentation of calibration, maintenance, and repair is kept for at least one year after work is completed? Yes ATG/IM - ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational? Yes ATG/IM - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes ATG - The tank was filled to at least the minimum level required to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits? Yes Tank 4 ATG/IM Does the ATG system have a valid annual test?Yes Tank 4 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 4 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes Tank 7 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 7 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes 2025-06-05 Page 3 of 5 Tank 7 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes DISPENSER RESPONSES Dispenser upper Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser lower Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Jun '24 Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24 Jan '25 Feb '25 Mar '25 Apr '25 May '25 Tank 4 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 7 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2025-06-05 Page 4 of 5 Prepared by fueloperator.com Inspection Information Inspector:Ottley, Melissa Record Created:June 5, 2025, 11:03 a.m. Inspection Date:June 5, 2025 2025-06-05 Page 5 of 5