Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-005784
EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 00.0037 0.0000 0.0000 00.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 00.0037 0.0000 0.0000 00.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 03/04/2024 2000007 Harts #80234 2087 S Main St Nephi, UT 84648 Danny Jones UT379 55 PSI Regular 0 44 15 44 0 0 0 30 44 0 0 0 Pass Premium 0 32 15 32 0 0 0 30 32 0 0 0 Pass Diesel 0 58 15 58 0 0 0 30 58 0 0 0 Pass 03/04/2024 Danny Jones UT379 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV0//'DQGHOHFWURQLFOLQHOHDNGHWHFWRUV(//'ZLWKVXEPHUVLEOH WXUELQHSXPS673V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\POOLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGVWLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGVWKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHWWULSZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #80234 2087 S. Main St Nephi, UT 84648 2000007 Harts Gas & Food LLC. P.O. Box 418 American Fork, UT 84003 801-592-5948 03/04/2024 1 Regular VR FXIV 4 33 15 110 1 12 4 4 4 4 4 2 Premium VMI LD2000 4 31 19 120 1 14 3 4 4 4 4 3 Diesel VR FXIDV 4 31 18 100 1 12 3 4 4 4 4 Danny Jones UT-379 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #80234 2000007 1 Regular VRTLS 350 15233 120" 4 4 4 4 101" 4 1.5" 4 4 2 Premium VRTLS 350 8072 120" 4 4 4 4 99" 4 1.5" 4 4 3 Diesel VRTLS 350 7063 120" 4 4 4 4 99 1/4" 4 2.5" 4 4 Danny Jones UT-379 03/04/2024 pei.org 51 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-11 EMERGENCY STOP SWITCH OPERATION INSPECTION )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVSURFHGXUHLVWRYHULI\WKHRSHUDWLRQRIDOOHPHUJHQF\VWRSVZLWFKHVEXWWRQV(VWRSV(DFK(VWRSPXVWGLVFRQQHFWSRZHUWRGLV SHQVHUVVXEPHUVLEOHWXUELQHSXPSV673VDQGDOOQRQLQWULQVLFDOO\VDIHHOHFWULFDOHTXLSPHQWLQFODVVLILHGDUHDV7HVWHDFK(VWRSVHSD UDWHO\6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH (VWRS1XPEHURU,' /RFDWLRQ (VWRSVODEHOHGDQGORFDWHG ZKHUHHDVLO\DFFHVVLEOH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 6\VWHPLVIXOO\SRZHUHGDQG LQQRUPDORSHUDWLQJFRQGLWLRQ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $IWHUDFWLYDWLQJ(VWRSSRZHUKDVEHHQGLVFRQQHFWHGIURP D$OOGLVSHQVLQJGHYLFHVRQDOO LVODQGV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R E$OO673VIRUDOOIXHOJUDGHV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R F$OOSRZHUFRQWURODQGVLJQDO FLUFXLWVDVVRFLDWHGZLWKWKHGLV SHQVLQJGHYLFHVDQGWKH673V" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R G$OORWKHUQRQLQWULQVLFDOO\ VDIHHOHFWULFDOHTXLSPHQWLQ FODVVLILHGDUHDVVXUURXQGLQJ IXHOGLVSHQVLQJGHYLFHV" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $OOLQWULQVLFDOO\VDIHHOHFWULFDO HTXLSPHQWUHPDLQVHQHUJL]HG DIWHU(VWRSDFWLYDWLRQ" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $IWHUWHVWLQJKDV(VWRSEHHQ UHVHWDQGSRZHUUHHVWDEOLVKHG WRQRUPDORSHUDWLQJFRQGLWLRQ" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWROLQHVDGLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies, Inc.801-886-9224 Harts #80234 2000007 03/04/2024 1 Store-Front 4 4 4 4 4 4 4 4 4 Danny Jones UT-379