HomeMy WebLinkAboutDAQ-2025-0028171
DAQC-PBR047240001-25
Site ID 4724 (B1)
MEMORANDUM
TO: FILE – JAVELIN ENERGY LLC – O MOON 2-26Z1
THROUGH: Rik Ombach, Minor Source Oil and Gas Section Manager
FROM: Fred Goodrich, Environmental Scientist
DATE: June 2, 2025
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: May 28, 2025
SOURCE LOCATION: Lat: 40.4551887512207, Long: -109.967956542969
Uintah County
Business Office:
Javelin Energy Management Partners, LLC
6333 North State Highway 161, Suite 500
Irving, TX 75039
SOURCE TYPE: Tank Battery
API: 4304731480
SOURCE CONTACTS: Brian Shpakoff, Corporate Environmental Contact
Phone: 682-209-2074, Email:
Brian.Shpakoff@crescentenergyco.com
Jennifer McQueen, Corporate Environmental Contact
Phone: 720-705-8042, Email: jmcqueen@slrconsulting.com
OPERATING STATUS: Permanently down.
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories.
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
No Flare Controls, Site has Line Power. The source registered:
2,901 Estimated Oil BBL.
, -
2
DOGM current 12 month rolling production is: 30 BBL's
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT Engine - Pneumatic, Tank
General Provisions Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines 0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile source dust 10%. [ R307-201-3] In Compliance. No visible emissions were detected during evaluation. VOC emissions are, at all times, minimized as reasonably practicable by equipment design, maintenance and operation practices. [R307-501-4(1)] In Compliance. Uncontrolled source. All other internal tank battery components appear to meet emission standard. All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as applicable. Tagging and record keeping requirements are not required. [R307-502-4] In Compliance. This source does not use continuous bleed controllers. Truck loading is done by bottom filling or submerged fill pipe. [R307-504(1)] In Compliance. The truck loading valves were built and designed for submerged loading. Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. All hatches were found closed at the start of the evaluation. Associated gas is routed to a process unit for combustion, a sales pipeline or an operating VOC control device, except in an emergency. An emergency release is unanticipated, temporary, infrequent, unavoidable, =24 hrs. and is not due to operator negligence. Low pressure gas from working loss, breathing loss and oil flashing is not "associated gas". [R307-511-4(1)] In Compliance. Associated gas found properly routed to pipeline at the time of inspection. Emission Inventory An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The operator submitted for the 2023 emissions inventory. Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Source appears to be properly registered at the time of inspection. Applicable Federal Regulations
3
PREVIOUS ENFORCEMENT
ACTIONS: None in the past 5 years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance.
Operator has started removal of some equipment for upcoming
plugged and abandonment. No emissions were detected during
inspection.
RECOMMENDATION FOR
NEXT INSPECTION: DAQ recommends a follow up inspection at a later date.
Verification of source status would be well documented for
future records.
UNDER EPA DECREE: No.
ATTACHMENTS: None.