Loading...
HomeMy WebLinkAboutDERR-2025-004281EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 03/05/2025 Harts #80232 5175 W. 9600 N. Elwood, UT 84337 801-592-5948 John Hreinson Zak Goldberg UT-435 50 PSI Regular 0 59 15 59 0 0 0 30 59 0 0 0 Pass Prm 0 47 15 47 0 0 0 30 47 0 0 0 Pass Diesel, Sats 11-14 0 34 15 34 0 0 0 30 34 0 0 0 Pass 03/05/2025 Zak Goldberg UT-435 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Harts #80232 5175 W. 9600 N. Elwood, UT 84337 0100640 Harts Gas & Food LLC P.O. Box 418 American Fork, UT 84003 801-592-5948 03/05/2025 1 Regular VR FX1V 4 30 16 120 2 10 6 4 4 4 4 2 Premium VR FX1V 4 31 14 140 2 12 4 4 4 4 4 3 Diesel VR FX1DV 4 31 15 190 2 11 6 4 4 4 4 Zak Goldberg UT-435 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #80232 0100640 1 Regular VR TLS 350 19951 119.82 4 4 4 4 100 4 1 4 4 2 Premium VR TLS 350 15104 119.82 4 4 4 4 99 3/4 4 1 4 4 3 Diesel VR TLS 35- 19951 119.82 4 4 4 4 100 4 1 4 4 Zak Goldberg UT-435 03/05/2025 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Harts #80232 0100640 03/05/2025 Reg STP Regular 4 4 4 4 4 4 4 4 Prm STP Premium 4 4 4 4 4 4 4 4 Dsl STP Diesel 4 4 4 4 4 4 4 4 Zak Goldberg UT-435 1 of 3 parkland fueling equipment worksheet 022023 Fueling Equipment Worksheet Store # / Name: _________________________ Address:__________________________________ ***** FUEL TANKS Product: If Other, list Product: AST / UST Tank Type (ACT 100, FRP, Steel, STI-3) Tank Material? Double Wall? ( Y / N ) Capacity Gallons (per chart if available): Tank Chart available? Diameter Inches (measured): Length Inches (per chart): Drop tube present? # Of inches Drop Tube of bottom. Stage I VR Type (Coaxial, 2-pt) Swivel Type Stage I Adaptor ( Y / N) Vapor Bucket type (SW / DW / Manway? Tank #: Tank #: Tank #: Tank #: Tank #: Tank #: U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N SW / DW / M SW / DW / M SW / DW / M SW / DW / M SW / DW / M SW / DW / M Overfill Protection Present / Not Present ( P / NP ) Ball Float (BF), Drop Tube Valve (DTV) BF & Ex Alarm (BFE) ; Ex. Alarm (EA) P / NP P / NP P / NP P / NP P / NP P / NP Overspill Containment Catchment Basin, Multi-Port w/ bucket Spill Bucket Single or Double wall? Model / Manufacturer: Overspill Condition ( G / B )? Drain Valve Functional? Spill Bucket Size? CB / MP CB / MP CB / MP CB / MP CB / MP CB / MP S / D S / D S / D S / D S / D S / D G / B G / B G / B G / B G / B G / B Y / N Y / N Y / N Y / N Y / N Y / N Fill Riser Adaptor? (Locking, Stationary, Swivel) L / ST / SW L / ST / SW L / ST / SW L / ST / SW L / ST / SW L / ST / SW ESO Button(s) Operational? Y / N Y / N Y / N Y / N Y / N Y / N Location of ESO (s) ***** FUEL SUB-PUMPS Sub-Pump (STP) No: Tank #: Product: U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other Harts #10 2 of 3 parkland fueling equipment worksheet 022023 FUEL SUB-PUMPS (Cont.) If Other, list Product: Leak Detector Type: E / M E / M E / M E / M E / M E / M Manufacturer? Serial Number: Type: FX, PLD, FE, Etc. Sub Pump Sump/Liner Type: (Sump/Liner/None) Sump Condition (Good / Bad) Turbine Pump (STP) Horsepower? Beaudreau Sensors present? ( Y / N ) Positioned on bottom? ( Y / N ) ATG Sensors present? ( Y / N ) Positioned on bottom? ( Y / N ) S / L / None S / L / None S / L / None S / L / None S / L / None S / L / None G / B G / B G / B G / B G / B G / B Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N ***** FUEL DISPENSERS Number of Hoses: Condition of Hoses (G / B)? Dispenser Model: Type Code: (Single, Dual, Multi.) Manufacturer? Blender Installed? Blender = Mechanical / Electronic? Blend Ratio? Are Shear Valves anchored? Shear Valve Operational? Disp. #: Disp. #: Disp. #: Disp. #: Disp. #: Disp. #: G / B G / B G / B G / B G / B G / B S / D / M S / D / M S / D / M S / D / M S / D / M S / D / M Y / N Y / N Y / N Y / N Y / N Y / N M / E M / E M / E M / E M / E M / E Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Disp. Flex Hose (Present? Y/N) Disp. Flex Hose Booted/CP/Cont.? Y / N Y / N Y / N Y / N Y / N Y / N B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. Flex Hose or Swing Joint? F / S F / S F / S F / S F / S F / S DWFRP Boots Connected or Open? C / O C / O C / O C / O C / O C / O Dispenser Sump/Liner Type:(Sump/Liner/None) Sump Condition (G / B) Beaudreau Sensors present ? ( Y / N ) Positioned on bottom? ( Y / N ) ATG Sensors Present? ( Y / N ) Positioned on bottom? ( Y / N ) S / L / None S / L / None S / L / None S / L / None S / L / None S / L / None G / B G / B G / B G / B G / B G / B Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N 3 of 3 parkland fueling equipment worksheet 022023 Additional Comments: Company:_______________________________________ Representative:___________________________________ Date:___________________________________________ ***** FUEL LINES Product: If Other, list Product: Type: DWFRP, FRP, Steel, Unknown) Type (Enviroflex, Flexworks, Etc.)? Manufacturer ? STP Flex Hose present? STP Flex Hose Booted /CP/ Cont.? Tank #: Tank #: Tank #: Tank #: Tank #: Tank #: U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other Y / N Y / N Y / N Y / N Y / N Y / N B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. B / CP / Cont. Sub Pump Connection: (Flex Hose, Swing Joint, Unknown) DWFRP Boots Connected or Open? F / S / U F / S / U F / S / U F / S / U F / S / U F / S / U C / O C / O C / O C / O C / O C / O ***** VENTS Product: Product: Location: C=Canopy; L=Lot; B=Building Manifolded Aboveground? ( Y / N ) Pressure/Vacuum Cap Type? U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other U UL+ S D Other C / L / B C / L / B C / L / B C / L / B C / L / B C / L / B Y / N Y / N Y / N Y / N Y / N Y / N ***** CATHODIC PROTECTION Impressed Current System: (Y / N) Rectifier Location ? Rectifier Log on Site ? Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N Y / N ***** AUTOMATIC TANK GAUGE Model? Comments: Software Version No? Is Software up to date? Y / N ***** RELEASE DETECTION METHOD Tank Primary Release Detection: Comments: Tank Secondary Release Detection: Piping Primary Release Detection: Piping Secondary Release Detection: **** OPERATIONAL CHECKS Gasoline/Compliance Binder Present? Y / N Last Test Dates? 30-Day Inspections completed by: UST Permit / Delivery Certificate Present (onsite) and Current? Y / N Emergency Response Plan Posted? Y / N SPCC Available (if required) Y / N