Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-004183
PRODUCTPIPINGINTEGRITYTESTING FacilityName: GenevaRockProducts,Inc. Owner: GenevaRockProducts,Inc. Address: 748West300 South Address: 730North1500West City,State,Zip: SaltLakeCity,Utah84104 City,State,Zip: Orem,Utah84057 FacilityI.D.#: 4000412 Phone#: 801-802-6954 TestingCompany:Westech Phone#:801-266-2545 Date: 4/9/25 Thisprocedureistotesttheintegrityofproductpiping.TestswereperformedwithPetro-Titeline tester. TankNumber 1 ProductStored DSL PipingRun Only PipingType FRP TestPressure(PSI) 50 TestDuration(minutes) 30 LeakRate(GPH) 0.000 TestResults ☒Pass☐FailPass☐FailPass☐FailPass☐Fail Comments:Tester’sNameTaberDeHart,UT-0394Tester’s Signature MECHANICALANDELECTRONICLINELEAKDETECTORPERFORMANCE TESTS FacilityName: GenevaRockProducts,Inc. Owner: GenevaRockProducts,Inc. Address: 748West300South Address: 730North1500West City,State,Zip: SaltLakeCity,Utah84104 City,State,Zip: Orem,Utah84057 FacilityI.D.#: 4000412 Phone#: 801-802-6954 TestingCompany:Westech Phone#:801-266-2545 Date: 4/9/25 Thisdatasheetcanbeusedtotestthemechanicallineleakdetector(MLLD)andelectroniclineleakdetector(ELLD)withsubmersibleturbine pump (STP) systems. See PEI/RP 1200 Sections 9.1 and 9.2 for test procedures. LineNumber 1 ProductStored Diesel LeakDetector Manufacturer Red Jacket LeakDetectorModel FX Type OfleakDetector ☒MLLDELLDMLLDELLDMLLDELLDMLLDELLD MLLD(ALLPRESSUREMEASURMENTSAREMADE INPSIG) STPfulloperatingpressure 30 Checkvalveholdingpressure 21 Lineresiliency(ml)(linebleedbackvolumeasmeasured fromcheckvalveholdingpressureto0 psig) 50 Step through time in seconds (time the MLLD hesitates at meteringpressurebeforegoingtofulloperatingpressureas measuredfrom0sigwithnoleakinducedontheline) 1 Meteringpressure(STPpressurewhensimulatedleakrate3 gphat10psig) 12 Openingtimeinseconds(thetimetheMLLDopensto allow fullpressureaftersimulatedleakis stopped) 5 DoestheSTPpressureremainatorbelowthemetering pressureforatleast60secondswhenthesimulatedleakis induced? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No Doestheleakdetectorreset(trip)whenthelinepressureis bledofftozeropsig? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No DoesSTPproperlyclycleon/offundernormalfuelsystem operatingconditions? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No A"No"answertoanyoftheabovequestionsindicatesthattheMLLDfailsthetest. ELLD(ALLPRESSUREMEASURMENTSAREMADEINPSIG) STPfulloperatingpressure Howmanytestcyclesareobservedbeforealarm/shutdown occurs? Doesthesimulatedleakcauseonalarm?Yes ☐NoYes ☐NoYes ☐NoYes ☐No A"No"answertotheabovequestionindicatesthattheELLDfailsthetest. DoesthesimulatedleakcauseanSTP shutdown?Yes ☐NoYes ☐NoYes ☐NoYes ☐No Test Results ☒Pass☐FailPass☐FailPass☐FailPass☐Fail Comments:Tester’sNameTaberDeHart,UT-0394Tester’s Signature AUTOMATICTANKGAUGEOPERATIONINSPECTION FacilityName: GenevaRockProducts,Inc. Owner: GenevaRockProducts,Inc. Address: 748West300 South Address: 730North1500West City,State,Zip: SaltLakeCity,Utah84104 City,State,Zip: Orem,Utah84057 FacilityI.D.#: 4000412 Phone#: 801-802-6954 TestingCompany:Westech Phone#:801-266-2545 Date: 4/9/25 Thisprocedureis todeterminewhethertheautomatictankgauge(ATG)isoperatingproperly.SeePEI/RP1200Section8.2fortheinspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. TankNumber 1 ProductStored DSL ATGBrandand Model TLS-300 1.TankVolume,gallons 11,267 2.TankDiameter, inches 92 3.AfterremovingtheATGfromthe tank, ithasbeen inspectedandanydamagedormissingparts replaced? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No 4.Floatmovesfreelyonthestemwithoutbinding? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No 5.Fuelfloatlevelagreewiththevalue programmed intotheconsole? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No 6.Waterfloatlevelagreewiththevalueprogrammed intotheconsole? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No 7.Inchlevelfromthebottomofthestemwhen90% alarmistriggered? 79 8.Inchlevelatwhichtheoverfillalarmactivates corresponds with the value programmed in the gauge? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No 9.Inchlevelfromthebottomwhenthewaterfloat firsttriggersan alarm? 2 10.Inchlevelatwhichthewaterfloatalarmactivates corresponds with the value programmed in the gauge? ☒Yes ☐NoYes ☐NoYes ☐NoYes ☐No IfanyanswersinLines3,4,5,or6are"No"thesystemhasfailedthetest. TestResults ☒Pass☐FailPass☐FailPass☐FailPass☐Fail Comments:Tester’sNameTaberDeHart,UT-0394Tester’s Signature