Loading...
HomeMy WebLinkAboutDDW-2025-005016INTERSTATE 84 IN T E R S T A T E 8 4 Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION CO V E R S H E E T FROM SURVEY SOUTH ƒ4  EAST BETWEEN THE SOUTH QUARTER CORNER AND THE SOUTHEAST CORNER OF SECTION , TOWNSHIP  NORTH, RANGE 1 EAST, SALT LAKE BASE MERIDIAN PLAT 3C BOOSTER PUMP STATION CONSTRUCTION DOCUMENTS FOR WASATCH PEAKS RANCH SECTION 14 TOWNSHIP 4 NORTH, RANGE 1 EAST MORGAN COUNTY, UTAH VICINITY MAP NORTH BASIS OF BEARING LEGAL DESCRIPTION BENCHMARK CONSULTANTS CIVIL ENGINEER: SURVEYOR: GEOTECHNICAL ENGINEER: AGENCY CONTACTS SITE INFORMATION FROM SURVEY TOTAL SITE AREA LIMITS OF CONSTRUCTION .3 ACRES 1, S.F. PLANNING: ENGINEERING: GAS SERVICE: ELECTRIC: PROPERTY OWNER: ENVIRONMENTAL SCIENTIST: C. 1.PRO-ECT COORDINATES WERE COMPUTED FROM A MODIFIED STATE PLANE UTAH NORTH =ONE 431 US FOOT. .PRO-ECT COORDINATES HAVE BEEN GENERATED BY A STATIC SURVEY. ALL COORDINATES LISTED IN THESE TABLES ARE PRO-ECT BASED COORDINATES. 3.COMBINED SCALE FACTOR 1.311 4.GEOID MODEL 1A .LOCAL SITE LATITUDE N41ƒ . LONGITUDE W111ƒ4 3.43 HEIGHT 4. .FALSE NORTHING OFFSET: 3,,. FALSE EASTING OFFSET:1,,. SURVEY CONTROL NOTES PROPERTY LINE (TYP.) UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY: PROJECT LOCATION WPR UTILITY DISTRICT WPR ROAD AND FIRE DISTRICT PLAT 3C BOUNDARY BOHMAN PROPERTY PEAKS VIEW ROAD NORTH VILLAGE WASATCH PEAKS ROAD MEADOWS VIEW DRIVE WASATCH PEAKS ROAD S-GENERAL STRUCTURAL NOTES S-1 SPECIAL INSPECTION MATRICES S-1TYPICAL DETAILS AND ABBREVIATIONS S-11 FOUNDATION PLAN S-1 FOUNDATION DETAILS EELECTRICAL COVER SHEET E1 ELECTRICAL GENERAL NOTES EPOWER SINGLE LINE DIAGRAM E3 ELECTRICAL DETAILS ES11 SITE PLAN VIEW ES1ENLARGED SITE PLAN VIEW ES13 ENLARGED VIEW I1 INSTRUMENTATION BILL OF MATERIALS LEGEND I11 INSTRUMENTATION PANEL LAYOUT I31 INSTRUMENTATION DC WIRING DIAGRAM SHEET LIST TABLE SHEET NO.SHEET TITLE C.COVER SHEET C.1 GENERAL NOTES C.OVERALL W1.BOOSTER PUMP STATION SITE GRADING PLAN W.BOOSTER PUMP STATION YARD PIPING - SUCTION W.1 BOOSTER PUMP STATION YARD PIPING - DISCHARGE D1.DETAILS I D1.1 DETAILS II D1.DETAILS III NO T F O R CO N S T R U C T I O N Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION GE N E R A L N O T E S C.1 ENGINEERING GENERAL CONSTRUCTION NOTES ENGINEERING SITE NOTES ENGINEERING GRADING NOTES PLAT 3C BOOSTER PUMP STATION GENERAL NOTES MATERIALS NOTESGENERAL NOTES NO T F O R CO N S T R U C T I O N P1 P2 G G4 G G3 G1 D G G G G G1 G1G13 G11 F1 F D4 D41 D43 D44D4 D4 D4 D4 D4DD1 DD3 D4 DD DD BOHMAN PROPERTY Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION LEGEND GENERAL NOTES C. OV E R A L L NO R T H NO T F O R CO N S T R U C T I O N W1. BO O S T E R P U M P S T A T I O N S I T E GR A D I N G P L A N NORTH PLAN VIEW Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION LEGEND GENERAL NOTES NO T F O R CO N S T R U C T I O N W. BO O S T E R P U M P S T A T I O N YA R D P I P I N G - S U C T I O N NORTH Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION LEGEND GENERAL NOTES PLAN VIEW - SUCTION WATER LINE PROFILE - SUCTION WATER LINE NO T F O R CO N S T R U C T I O N W.1 BO O S T E R P U M P S T A T I O N YA R D P I P I N G - D I S C H A R G E NORTH PLAN VIEW - DISCHARGE WATER LINE Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION LEGEND GENERAL NOTES PROFILE - DISCHARGE WATER LINE NO T F O R CO N S T R U C T I O N DE T A I L S I D1.Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION NO T F O R CO N S T R U C T I O N DE T A I L S I I D1.1Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION NO T F O R CO N S T R U C T I O N Model  Design Flow Rate: Minimum Power: GPM # Volt  HPPump DESIGN SPECIFICATIONS Duty Pump Details:GPM # PSI Boost Phase TDH VP3V;-13;;;B43OAS-4-SS 4  13 411 3 BOOSTER SYSTEM PUMP STATION WASATCH PEAKS 60% Pre-Final PART NO: TITLE: PROJECT: MATERIAL D 1 OF 1REV PRECISION PUMPING SYSTEMS6515 BUSINESS WAY BOISE, IDAHO 83716 208-323-5300 www.gopps.us LEVEL: SIZE:SCALE:DATE: 2/14/2025 SHEET: UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL: ±1/8"ONE PLACE DECIMAL: ±.10 TWO PLACE DECIMAL: ±.05 DO NOT SCALE DRAWING NTSDRAWN: ACL 3V-4-NJ-NF-FM-CT-PT JOB: SALESMAN: Rob Dickson PRE-FABBED CONCRETE COLOR - NA POTABLE Piping: SS 304, NSF NAPGUARD BLUE, NOT FOR CONSTRUCTION; NOT FOR FABRICATION REV.DESCRIPTION DATE APVD REVISIONS ITEM NO.DESCRIPTION Size QTY. 1 AC, MINI-SPLIT AIR HANDLER 1 2 AC, MINI-SPLIT AIR HANDLER 1 3 BUILDING, PRE-CAST CONCRETE 126"x288"1 4 CONTROL PANEL 1 5 DEHUMIDIFIER 50 PTD 2 6 DISMANTLING JOINT 4"2 7 DRAIN, FLOOR 6"3 8 DRIVE, VFD 3 9 EXHAUST FAN 12"2 10 EXIT SIGN, EMERGENCY LIGHT 2 11 FIRE EXTINGUISHER (48" AFF)20LB 2 12 FLOW METER, BADGER 4"1 13 GFCI OUTLET 15A 8 14 HVAC, MINI-SPLIT CONDENSER 1 15 HVAC, MINI-SPLIT CONDENSER 1 16 JIB CRANE 1 17 LIGHT FIXTURE, EXTERNAL 2 18 LIGHT FIXTURE, LED 24"3 19 LIGHT SWITCH 4 20 LOAD CENTER (P-1)1 21 LOUVER GRILLE 12" X 12"4 22 LOUVER, WALL, GRAVITY 12" X 12"1 23 MAIN DISTRIBUTION PANEL (MDP-1)1 24 PUMP, VMS, 22SV 20HP 3 25 PRESSURE SENSOR, -14.5..362.5PSI, LED DISPLAY, 4-20MA, IFM 1/4"1 26 PRESSURE SENSOR, -14.5..145PSI, LEDDISPLAY, 4-20MA, IFM 1/4"1 27 PRESSURE GAUGE, 100PSI, NSF 2-1/2"1 28 PRESSURE GAUGE, 300PSI, NSF 2-1/2"1 29 RADIANT HEATER, 46IN 3 30 SAMPLE TAP 1/2"1 31 SENSOR, INTRUSION 2 32 SHUTTER, 10"10"1 33 SMOKE ALARM, GENTEX 2 34 STATIC MIXER 4"1 35 THERMOSTAT 2 36 TRANSFORMER 1 37 VALVE, AIR RELIEF 3/4"5 38 VALVE, BUTTERFLY, LUG, LEVER, 250 PSI 2"7 39 VALVE, BUTTERFLY, LUG, LEVER, 250 PSI 4"2 40 VALVE, CHECK, SILENT 2"3 41 VALVE, SURGE ANTICIPATION 2"1 1  PLAN VIEW 1 1 11 311 3 1  3 4 31 13311111  13 333133   3141 1 1CHEMICAL ROOM FOR FUTURE EQUIPMENT 13 NEC WORKING SPACE KEEP CLEAR AA 3 NOTE TOTAL ESTIMATED WEIGHT: , LBS 3 4 4 33 DUTY PUMP 1   SECTION A-A 1 1133 11 14  FRONT VIEW 4 SUCTION FINAL CONNECTIONS AND FINAL FITTINGS BY OTHERS 4 DISCHARGE FINAL CONNECTIONS AND FINAL FITTINGS BY OTHERS 1 DRAINS 33 B B 1 1  SECTION B-B  SAV DISCHARGE, PIPING AND FINAL CONNECTIONS BY OTHERS . PPS RECOMMENDS DISCHARGE TO CISTERN OR CITY SUPPLIED DRAIN END VIEW SHIM PACK SHIM PACK 1 BLOWOUT 1 PORT 1 PORT 1-1 PORT 34 DE T A I L S I I I D1.Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o f t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N S   3      AS S H O W N NOT FOR CONSTRUCTION NO T F O R CO N S T R U C T I O N 4.00 DOCUMENTS AND LIMITATIONS 4.01 THESE STRUCTURAL DOCUMENTS, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, ARE INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION BY KIMLEY-HORN AND ASSOCIATES, INC. MUST BE WITHOUT LIABILITY TO KIMLEY-HORN AND ASSOCIATES, INC. 4.02 IT IS UNDERSTOOD THAT THE CONSULTANT MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, AS TO FINDINGS, DESIGNS, RECOMMENDATIONS, SPECIFICATIONS, OPINION, OR PROFESSIONAL ADVICE, EXCEPT THAT THESE INSTRUMENTS OF SERVICE HAVE BEEN PREPARED IN ACCORDANCE WITH THE CURRENT GENERALLY ACCEPTED PROFESSIONAL ENGINEER PRACTICES. 4.03 ALL NON-STRUCTURAL ELEMENTS INDICATED ON THE STRUCTURAL DRAWINGS HAVE BEEN SHOWN IN GENERAL TO THE RELATIONSHIP TO THE STRUCTURAL ELEMENTS ONLY. ACCORDINGLY, THEY MUST NOT BE ASSUMED TO BE ACCURATE AND REFERENCE MUST BE MADE TO THE APPROPRIATE CONSULTANT(S), PLANS, AND SPECIFICATIONS. 4.04 NOTES ON THIS AND THE FOLLOWING SHEETS ARE PART OF THE PROJECT REQUIREMENTS BUT ARE NOT INTENDED TO REPLACE THE PROJECT SPECIFICATIONS. IN CASE OF CONFLICTS BETWEEN THE REQUIREMENTS OF THE SPECIFICATIONS AND THESE NOTES, THE MORE STRINGENT REQUIREMENT MUST APPLY. 4.05 IT MUST BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE LOCATION OF EMBEDDED ITEMS, SLEEVES, ANCHORS, AND PENETRATIONS AS REQUIRED AND/OR FURNISHED BY THE OTHER TRADES. 5.01 IT IS UNDERSTOOD THAT THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK ON THE PROJECT. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THE PERSONS AND PROTECT THEM AGAINST INJURY. LIKEWISE, THE CONTRACTOR MUST PROTECT ALL PROPERTY AGAINST DAMAGE OR LOSS. 5.02 THE CONTRACTOR MUST COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, REGULATIONS, AND ORDERS OF ANY PUBLIC BODY HAVING JURISDICTION FOR THE SAFETY OF PERSONS OF PROPERTY. 5.03 THE CONTRACTOR'S DUTIES AND RESPONSIBILITIES FOR THE SAFETY AND PROTECTION OF THE WORK MUST CONTINUE UNTIL SUCH TIME AS THE WORK IS SATISFACTORILY COMPLETED, AND THE ENGINEER OF RECORD HAS ISSUED A NOTICE TO THAT EFFECT TO THE OWNER AND THE CONTRACTOR. 5.04 ALL STRUCTURAL MEMBERS SHOWN HEREIN HAVE BEEN DESIGNED FOR THE FINAL DESIGN LOADS PROVIDED IN THIS DOCUMENT IN THE FINAL ERECTED CONDITION SHOWN HEREIN. THE CONTRACTOR IS RESPONSIBLE FOR CONDITIONS ENCOUNTERED DURING ERECTION AND HANDLING AND NECESSARY TEMPORARY BRACING AND SHORING. SHORING AND BRACING SHALL BE DESIGNED TO PRECLUDE ANY STRUCTURAL ELEMENT FROM BEING OVERSTRESSED AT ANY POINT DURING CONSTRUCTION. SHORING SHALL BE DESIGNED BY A PROFESSIONAL ENGINEERED LICENSED IN THE STATE OF UTAH AND DRAWINGS SHALL BE SIGNED AND SEALED. 3.01 BEFORE STARTING WORK, CONTRACTOR MUST VERIFY ALL DIMENSIONS ON THE SITE, AND REPORT ANY DISCREPANCIES IMMEDIATELY TO THE ENGINEER OF RECORD. 3.02 THE CONTRACTOR, BEFORE STARTING ANY WORK, MUST CHECK ALL DIMENSIONS GIVEN ON THE STRUCTURAL DRAWINGS, RELATING TO GRID LINES, COLUMN AND WALL LOCATIONS, STRUCTURAL AND FINISHED FLOOR ELEVATIONS, MEMBER SIZES, ETC., WITH THE PRECAST AND CIVIL DRAWINGS. IF ANY DISCREPANCY IS NOTICED, IT MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER, AND WORK MUST NOT COMMENCE UNTIL INSTRUCTIONS ARE RECEIVED FROM THE ENGINEER. 3.03 THE CONTRACTOR MUST REFER TO THE ENGINEER OF RECORD FOR HIS INSTRUCTIONS FOR ANY DIMENSION NOT GIVEN ON OR OBTAINABLE FROM THE CONSTRUCTION DRAWINGS. THE CONTRACTOR MUST NOT USE SCALE TO OBTAIN OR VERIFY ANY DIMENSION SHOWN ON THE CONSTRUCTION DRAWINGS. 6.01 REVIEW OF SHOP DRAWINGS BY THE ENGINEER OF RECORD IS LIMITED TO COMPLIANCE OF THE COMPLETED STRUCTURE WITH THE DESIGN CONCEPT AND INFORMATION GIVEN IN THE PLANS AND SPECIFICATIONS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DIMENSIONS, QUANTITIES, PERFORMANCE, SAFETY, COORDINATION WITH OTHER WORKS, AND ALL OTHER REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. REVIEW DOES NOT AUTHORIZE CHANGES TO CONTRACT. 6.02 THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR HIS REVIEW IN ACCORDANCE WITH A SCHEDULE OF SUBMITTALS ACCEPTABLE TO THE ENGINEER. THESE SHOP DRAWINGS MUST HAVE BEEN CHECKED BY, AND STAMPED WITH THE APPROVAL OF THE CONTRACTOR, AND IDENTIFIED AS THE ENGINEER MAY REQUIRE. THE DATA SHOWN ON THE SHOP DRAWINGS MUST BE COMPLETE WITH RESPECT TO DIMENSIONS, DESIGN CRITERIA, AND DULY SIGNED AND SEALED BY A PROFESSIONAL ENGINEER (WHERE APPLICABLE). 13.01 IN CAST-IN-PLACE CONCRETE WORK, NO OPENINGS MUST BE PERMITTED IN SLABS WITHIN A DISTANCE OF EIGHT INCHES FROM THE FACE OF A COLUMN OR EDGE OF SLAB. OPENINGS BETWEEN EIGHT TO TWENTY FOUR INCHES FROM THE FACE OF THE COLUMN OR EDGE OF SLAB MUST NOT GENERALLY BE PERMITTED EXCEPT WITH THE SPECIFIC APPROVAL OF THE ENGINEER OF RECORD. OPENINGS LOCATED GREATER THAN TWO FEET FROM THE FACE OF THE COLUMN OR EDGE OF SLAB ARE GENERALLY PERMITTED, SUBJECT TO APPROVAL OF THE ENGINEER OF RECORD. 13.02 OPENINGS IN CONCRETE WALLS MAY BE PERMITTED SUBJECT TO THE APPROVAL OF THE ENGINEER OF RECORD. 13.03 NO DRILLING THROUGH SLABS, BEAMS, COLUMNS, OR WALLS MUST BE CARRIED OUT EXCEPT WITH THE SPECIFIC APPROVAL OF THE ENGINEER OF RECORD. SUCH APPROVAL, IF GRANTED, MUST BE ON A CASE BY CASE BASIS. 8.01 WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER OF RECORD IS REQUIRED FOR ALL FIELD MODIFICATIONS TO THE STRUCTURAL SYSTEM INCLUDING, BUT NOT LIMITED TO, CUTTING OR DRILLING THROUGH ANY STRUCTURAL ELEMENT, CUTTING OR DRILLING THROUGH ANY STRUCTURAL ELEMENT, CUTTING OR THE RELOCATION OF MILD STEEL REINFROCEMENT, EMBED PLATES AND BOLTS AND PRECAST WALL CONNECTIONS, ETC. 5.00 CONSTRUCTION SAFETY 3.00 DIMENSIONS 6.00 SHOP DRAWINGS 8.00 FIELD MODIFICATION 13.00 OPENINGS IN SLABS, BEAMS AND WALLS 12.00 REINFORCED CONCRETE (CAST-IN-PLACE) 12.01 ALL CONCRETE SHALL BE CONSTRUCTED IN ACCORDANCE WITH IBC CHAPTER 19 & ACI-318, LATEST CODE ADOPTED EDITION. 12.02 ALL REINFORCING SHALL BE DETAILED, FABRICATED, & PLACED IN ACCORDANCE WITH CRSI 'MANUAL OF STANDARD PRACTICE,' LATEST EDITION, AND THE LATEST REVISION OF THE ACI DETAILING MANUAL. 12.03 ALL CAST-IN-PLACE CONCRETE AND POST INSTALLED ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH APPENDIX D OF ACI-318 AS MODIFIED BY THE APPLICABLE BUILDING CODE. 12.04 SPACING OF CONSTRUCTION OR CONTROL JOINTS IN WALLS EXPOSED TO VIEW SHALL NOT EXCEED 40 FEET UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CUT HALF OF THE HORIZONTAL REINFORCING AT CONTROL JOINTS. 12.05 SLEEVES EMBEDDED IN SLABS AND WALLS SHALL BE LOCATED CLEAR BETWEEN REINFORCING BARS AND SHALL MAINTAIN CLEAR SPACING EQUAL TO THE DIAMETER OF THE LARGEST SLEEVE IN ANY DIRECTION. SLEEVE GROUPS THAT DO NOT COMPLY WITH THE ABOVE REQUIREMENTS SHALL BE CONSIDERED AS AN OPENING AND REINFORCED PER NOTE, BELOW. 12.06 UNLESS NOTED OTHERWISE ON THE DRAWINGS: PROVIDE EXTRA REINFORCING ON ALL SIDES OF ALL MISCELLANEOUS WALL AND SLAB OPENINGS EQUAL TO ONE HALF THE INTERRUPTED REINFORCING BARS EACH SIDE, BUT NOT LESS THAN 2 - #5 FOR EACH LAYER OF REINFORCEMENT. EXTEND BARS CLAS 'B' LAP LENGTH, BUT NOT LESS THAN TWO FEET BEYOND EDGE OF OPENINGS. PROVIDE 2 - #5X4'-0" DIAGONAL BARS AT EACH CORNER FOR EACH LAYER OF REINFORCEMENT. 12.07 IN CAST-IN-PLACE CONCRETE WORK, NO OPENINGS SHALL BE PERMITTED IN SLABS WITHIN A DISTANCE OF EIGHT INCHES FROM THE FACE OF A COLUMN OR EDGE OF SLAB. OPENINGS BETWEEN EIGHT TO 24 INCHES FROM THE FACE OF THE COLUMN OR EDGE OF SLAB SHALL NOT GENERALLY BE PERMITTED EXCEPT WITH THE SPECIFIC APPROVAL OF THE ENGINEER. OPENINGS LOCATED GREATER THAN TWO FEET FROM THE FACE OF THE COLUMN OR EDGE OF SLAB ARE GENERALLY PERMITTED, SUBJECT TO APPROVAL OF THE ENGINEER. 12.08 NO DRILLING THROUGH WALLS SHALL BE CARRIED OUT EXCEPT WITH THE SPECIFIC APPROVAL OF THE ENGINEER. SUCH APPROVAL, IF GRANTED, SHALL BE ON A CASE-BY-CASE BASIS. CONRACTOR SHALL BE RESPONSIBLE FOR VERYFYING REINFORCEMENT LAYOUT USING NDT PRIOR TO DRILLING INTO CAST CONCRETE. 12.09 ALL SHOP DRAWINGS PERTAINING TO REBAR DETAILS SHALL BE SUBMITTED TO THE ENGINEER FOR HIS/HER REVIEW. CONCRETE MIX DESIGN FOR ALL CONCRETE WORK IS REQUIRED TO BE SUBMITTED TO THE ENGINEER FOR REVIEW. 12.10 CONCRETE SUPPLIER SHALL HAVE A QUALITY CONTROL PROCEDURE FOR THE PRODUCTION OF ALL CONCRETE AND MUST BE ACCEPTABLE TO THE ENGINEER AND MEETS CURRENT ACI STANDARDS. 12.11 CONSTRUCTION JOINTS SHALL BE AS APPROVED BY THE STRUCTURAL ENGINEER AND THE ARCHITECT. 12.12 EMBEDDED ITEMS THAT WILL SUPPORT STRUCTURAL STEEL CONSTRUCTION SHALL BE PLACED WITHIN THE TOLERANCES PRESCRIBED IN THE LATEST EDITION OF THE AISC 'CODE OF STANDARD PRACTICE.' GENERAL CONTRACTOR SHALL FIELD VERIFY LOCATION OF EMBEDDED ITEMS PRIOR TO FABRICATION AND DELIVERY OF STRUCTURAL STEEL TO THE PROJECT SITE. SHOP DRAWINGS FOR CAST-IN-PLACE CONCRETE SHALL INCLUDE LOCATIONS AND COORDINATION FO ALL EMBEDS, INCLUDING PRECAST SUPPORTS. 12.13 LAP SPLICES ARE ALL CLASS B TENSION LAP SPLICES, UNO. 12.14 PROVIDE A 3/4" CHAMFER ON ALL EXPOSED CORNERS OF CONCRETE. 12.15 THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT: A. CONCRETE CAST AGAINST & PERMANENTLY EXPOSED TO EARTH = 3" B. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #18 BARS = 2" #5 AND SMALLER BARS = 1 1/2" C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: #14 THROUGH #18 BARS = 1 1/2" #11 AND SMALLER BARS = 3/4" 9.00 FOUNDATIONS 9.01 FOUNDATIONS, FOUNDATION WALLS, FOUNDATION DRAINAGE, AND OTHER ITEMS RELATED TO THE SOILS ARE DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL INVESTIGATION PRODUCED BY LANGAN ENGINEERING AND ENVIRONMENTAL SERVICES, LLC. FOR PP3C BOOSTER PUMP STATION, LANGAN PROJECT NO. 170529901, DATED MARCH 27, 2025 AND EMAIL DATED APRIL 3RD, 2025. 9.02 DESIGN ALLOWABLE SOIL BEARING CAPACITY = 3000 PSF 9.03 SOIL UNIT WEIGHT = 125 PCF 9.04 MINIMUM DEPTH FROM EXTERIOR GRADE TO BOTTOM OF BUILDING PERIMETER FOOTINGS SHALL BE 36". 9.05 ACTIVE PRESSURE = 25 PSF/FT 9.06 SOIL FRICTION COEFFICIENT = 0.45 1.01 BUILDING CODE INTERNATIONAL BUILDING CODE 2018 (2018 IBC) 2018 UTAH STATE BUILDING CODE (2018 IBC) 1.02 BUILDING RISK CATEGORY = III 1.03 DESIGN LOADS A. DEAD LOAD:345 PSF (TO BE CONFIRMED BY PRECAST MANUFACTURER) B. LIVE LOAD: ROOF LIVE LOAD =20 PSF C. SNOW LOAD: GROUND SNOW LOAD =104 PSF SNOW EXPOSURE FACTOR, Ce =0.9 SNOW LOAD IMPORTANCE FACTOR, IS =1.0 THERMAL FACTOR, Ct =1.0 FLAT-ROOF SNOW LOAD, pf =72.1 PSF D.WIND LOAD: DESIGN WIND SPEED, V =109 MPH WIND EXPOSURE =C INTERNAL PRESSURE COEFFICIENT, GCpi =+/-0.55 E. EARTHQUAKE DESIGN DATA: PARAMETERS BASED ON THE GEOTECHNICAL INVESTIGATION PRODUCED BY LANGAN ENGINEERING AND ENVIRONMENTAL SERVICES, LLC. FOR PP3C BOOSTER PUMP STATION, LANGAN PROJECT NO. 170529901, DATED MARCH 27, 2025. IMPORTANCE FACTOR, IE =1.25 SITE CLASS =D DEFAULT SPECTRAL RESPONSE ACCELERATION, SS = 0.862g SPECTRAL RESPONSE ACCELERATION, S1 = 0.312g SPECTRAL RESPONSE ACCELERATION, SDS = 0.690g SPECTRAL RESPONSE ACCELERATION, SD1 = 0.413g SEISMIC DESIGN CATEGORY =D BASIC SEISMIC FORCE RESISTING SYSTEM =INTERMEDIATE PRECAST SHEAR WALLS (TO BE CONFIRMED BY PRECAST MANUFACTURER) 1.00 DESIGN LOADS 2.00 FUTURE EXPANSION 2.01 THE PROJECT IS NOT DESIGNED FOR FUTURE EXPANSION. 7.01. DELEGATED DESIGNS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE SUBMITTED AT THE TIME OF THE PERMIT APPLICATION BUT CONTAIN STRUCTURAL DESIGN ELEMENTS DESIGNED BY AN ENGINEER OTHER THAN THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, PANGOLIN STRUCTURAL. 7.02. THE DELEGATED DESIGNS LISTED BELOW HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN CRITERIA OF THE BUILDING, BUT THE ENGINEERING CONTAINED WITHIN IS THE RESPONSIBILITY OF THE LICENSED DESIGN PROFESSIONAL WHO HAS SEALED THE DOCUMENTS. 7.03. DELEGATED DESIGN ITEMS INCLUDE: PRECAST CONCRETE BUILDING 7.00 DELEGATED DESIGN 10.00 CONCRETE MATERIAL PROPERTIES 10.01 READY-MIX CONCRETE WORK SHALL CONFORM TO ASTM C94. 10.02 STRUCTURAL CONCRETE MATERIALS SHALL CONFORM TO THE FOLLOWING: A. TYPE II/IL PORTLAND CEMENT - ASTM C150 B. AGGREGATES (3/4" MAX) - ASTM C33 C. AIR ENTRAINING (6% +/- 1.5% AT RETAINING WALL FOOTINGS, 2% +/- 1% UNO) D. WATER REDUCING - ASTM C494 E. FLY ASH (MAX 25% BY WEIGHT), TYPE F - ASTM C618 F. WATER - CLEAN AND POTABLE G. REINFORCING STEEL: ASTM A615 GRADE 60 H. USE OF CALCIUM CHLORIDE IS NOT PERMITTED. 10.03 STRUCTURAL CONCRETE MIX SHALL CONFORM TO THE FOLLOWING: A. CONCRETE MIXES AND EXPOSURE CLASS ACCORDING TO ACI 318: CONCRETE: F'C PSI CLASS MAX WATER-TO-CEMENT RATIO ALL CONCRETE 4500 F2 0.45 10.04 REQUIRED SLUMP: 4" + 1" (BEFORE ADDITION OF SUPERPLASTICIZER) 10.05 ALL CONCRETE MATERIALS, PLACING AND HANDLING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ACI 318 AND ACI 301. CONCRETE WORK SHALL CONFORM TO THE CURRENT VERSION OF ACI 318. 10.06 SUBMITTALS: A.. DETAILED SHOP DRAWINGS OF REINFORCING BARS SHOWING NUMBER, SIZE, AND LOCATION. INCLUDING BAR LISTS AND BEND DIAGRAMS. B. MIX DESIGNS FOR EACH TYPE OF CONCRETE SPECIFIED SHALL BE SUBMITTED FOR APPROVAL. C. PRODUCT DATA AND MATERIAL CERTIFICATES. 11.00 REINFORCING 11.01 MATERIAL PROPERTIES: FY, KSI ASTM A. ALL BARS UNLESS NOTED 60 A615 14.01 ALL PRECAST CONCRETE SHALL BE DESIGNED AND DETAILED BY THE CONTRACTOR. ALL PRECAST CONCRETE SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. SUBMIT STAMPED SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER OF RECORD FOR APPROVAL INDICATING ALL PRECAST CONCRETE MEMBERS, CONNECTIONS, OPENINGS, CONCRETE COVER ON REINFORCEMENT, AND OTHER PRECAST CONCRETE RELATED ITEMS. 14.02 ALL PRECAST CONCRETE SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH ACI 318 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE”. 14.03 PROVIDE PRECAST STRUCTURAL CONCRETE UNITS WHOSE FIRE RESISTANCE MEETS PRESCRIPTIVE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION OR HAS BEEN CALCULATED ACCORDING TO ACI 216.1 OR PCI MNL 124, "DESIGN FOR FIRE RESISTANCE OF PRECAST PRESTRESSED CONCRETE" AS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 14.04 PROVIDE TEMPORARY STRUCTURAL FRAMING, SHORING, AND BRACING AS REQUIRED TO MAINTAIN POSITION, STABILITY, AND ALIGNMENT OF UNITS UNTIL PERMANENT CONNECTIONS ARE COMPLETE. 14.05 ALL PRECAST CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5000 PSI. 14.06 CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A706/A706M, GRADE 60. REINFORCING STEEL TO BE WELDED SHALL BE ASTM A706. 14.07 GALVANIZE ALL STEEL CONNECTION MATERIAL EXPOSED TO WEATHER. 14.08 DESIGN AND PROVIDE ALL EMBEDDED ITEMS SHOWN ON THE CONTRACT DOCUMENTS TO RESIST THE LOADS INDICATED. 14.09 PRECAST CONCRETE ELEMENTS ARE A DEFERRED SUBMITTAL ITEM. 14.00 PRECAST CONCRETE SHEET NUMBER 21 5 S o u t h S t a t e S t r e e t , S u i t e 4 0 0 | S a l t L a k e C i t y , U T 8 4 1 1 1 | T e l . N o . (3 8 5 ) 2 1 2 - 3 1 7 6 SEAL DR A W N B Y : DE S I G N E D B Y : CH E C K E D B Y : PRO J E C T No . : SC A L E : DE S C R I P T I O N DA T E # WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N SPRELIMINARYNOT FORCONSTRUCTIONAu t o d e s k D o c s : / / 0 9 6 3 6 0 0 1 0 W a s a t c h P e a k s R a n c h / W P R P ha s e 3 C B o o s t e r S t a t i o n ( R 2 4 ) . r v t 1" = 1 ' -0" S-000 DD PS JN 09 6 3 6 0 0 1 0 GE N E R A L S T R U C T U R A L N O T E S 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 SEALPRELIMINARYNOT FORCONSTRUCTION04/23/2025 NO T F O R CO N S T R U C T I O N 15.01 SPECIAL INSPECTIONS WILL BE PROVIDED IN COMPLICANCE WITH THE 2018 IBC PER SECTION 17. 15.02 OWNER WILL ENGAGE A SPECIAL INSPECTOR AND QUALIFIED TESTING AND INSPECTING AGENCY TO PERFORM FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. 15.03 THE GENERAL CONTRACTOR SHALL ASSIST AND COOPERATE WITH AN INDEPENDENT TESTING LABORATORY (TO BE RETAINED BY THE OWNER) WHICH SHALL CONDUCT ALL OF THE SPECIFIED TESTS REQUIRED FOR THE PROJECT AND REPORT THE RESULTS OF THESE TESTS DIRECTLY AND PROMPTLY TO THE ENGINEER FOR HIS REVIEW. 15.04 CONTRACTOR SHALL NOTIFY SPECIAL INSPECTOR AND TESTING AGENCY AT LEAST 48 HOURS IN ADVANCE OF ITEMS REQUIRED FOR SPECIAL INSPECTION. 15.05 ALL SPECIAL INSPECTION MONTHLY REPORTS SHALL BE SIGNED AND SEALED BY AN ENGINEER LICENSED IN THE STATE OF UTAH, WHO HAS RESPONSIBLE CHARGE OF THE SPECIAL INSPECTIONS PROGRAM. 15.06 A SPECIAL INSPECTIONS MEETING SHALL BE HELD ON SITE WITH THE ENGINEER OF RECORD, CONSTRUCTION COORDINATOR, INDEPENDENT TESTING AGENCY, AND SPECIAL INSPECTOR TO CLARIFY ALL SPECIAL INSPECTION REQUIREMENTS PRIOR TO BEGINNING TO WORK. 15.07 PORTIONS OF WORK REQUIRING SPECIAL INSPECTION: I. FOUNDATION: A. COMPACTED FILL, GRADING AND EXCAVATIONS B. SEE IBC TABLE 1705.3 BELOW FOR ANY ADDITIONAL REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION II. CONCRETE: A. CONTINUOUS INSPECTION AND TEST CYLINDERS FOR STRUCTURAL CONCRETE EXCEPT FOUNDATION CONCRETE OF 2500 PSI OR LESS III. REINFORCING STEEL: A. PLACING OF REINFORCING B. SAMPLING AND TESTING OF STEEL (MILL REPORTS AND IDENTIFICATION OF STEEL) C. SEE IBC TABLE 1705.3 BELOW FOR ANY ADDITIONAL REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION IV. STRUCTURAL OBSERVATIONS REQUIRED AS BY THIS ENGINEER OR THE BUILDING DEPARTMENT, THE OWNER SHALL EMPLOY AN ENGINEER APPROVED BY THIS ENGINEER TO PERFORM STRUCTURAL OBSERVATION AS DEFINED IN IBC SECTION 1704.6 15.00 SPECIAL INSPECTIONS TABLE 1705.6 (IBC 2018) REQUIRED VERIFICATION AND INSPECTION OF SOILS VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODIC DURING TASK LISTED 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. 4. VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. - X - X - X X - - X TABLE 1705.3 (IBC 2018) REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION TYPE CONTINUOUS SPECIAL INSPECTION REFERENCED STANDARDa PERIODIC SPECIAL INSPECTION 1. INSTALLATION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. - - X FOR SI: 1 INCH = 25.4 mm a: WHERE APPLICABLE, SEE ALSO SECTION 1705.12, SPECIAL INSPECTION FOR SEISMIC RESISTANCE. b: SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO COMMENCEMENT OF THE WORK. X-ACI 318: CH. 20, 25.2, 25.3, 26.5.1-26.5.3 IBC REFERENCE 1908.4 2. REINFORCING BAR WELDING: A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706; B. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"; AND C. INSPECT ALL OTHER WELDS. X X - AWS D1.4 ACI 318: 26.5.4 3. INSPECTION OF ANCHORS CAST IN CONCRETE X- ACI 318: 17.8.2 4. VERIFYING USE OF REQUIRED DESIGN MIX X-ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 5. AT THE TIME OF FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. 6. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. 7. INSPECTION OF MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. 8. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. 9. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. -X -X X- X- X- ASTM C 172 ASTM C 31 ACI 318: 26.4.5, 26.12 ACI 318: 26.4.5 ACI 318: 26.4.7-26.4.9 ACI 318: 26.10.2 ACI 318: 26.10.1(b) 1908.10 1908.6, 1908.7, 1908.8 1908.9 YES NO N/A SHEET NUMBER 21 5 S o u t h S t a t e S t r e e t , S u i t e 4 0 0 | S a l t L a k e C i t y , U T 8 4 1 1 1 | T e l . N o . (3 8 5 ) 2 1 2 - 3 1 7 6 SEAL DR A W N B Y : DE S I G N E D B Y : CH E C K E D B Y : PRO J E C T No . : SC A L E : DE S C R I P T I O N DA T E # WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N SPRELIMINARYNOT FORCONSTRUCTIONAu t o d e s k D o c s : / / 0 9 6 3 6 0 0 1 0 W a s a t c h P e a k s R a n c h / W P R P ha s e 3 C B o o s t e r S t a t i o n ( R 2 4 ) . r v t 1" = 1 ' -0" S-001 DD PS JN 09 6 3 6 0 0 1 0 SP E C I A L I N S P E C T I O N M A T R I C E S 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 SEALPRELIMINARYNOT FORCONSTRUCTION04/23/2025 NO T F O R CO N S T R U C T I O N CORNER INTERSECTION BAR WITH SAME SIZE AND SPACING AS HORIZONTAL REINFORCING -TYPICAL NOTE: CLASS "B" TENSION LAP SPLICE OR 24", WHICHEVER IS GREATER FREE END BAR WITH SAME SIZE AND SPACING AS HORIZONTAL REINFORCING WITH STANDARD 90° OR 180° HOOK -TYPICAL NO T E 1 NOTE 1 NOTE 1 NOTE 1 NO T E 1 SECTIONX X 4" M I N 4" M I N MIN 8" CONCRETE FOOTING UTILITY PIPE TO CLEAR SLEEVE BY 1/2" ALL AROUND NO UTILITIES TO PASS THRU FOOTING SLEEVE CONCRETE FILL (MINIMUM f'c = 500 PSI) NOTES: 1. NO UTILITIES BELOW COLUMN FOOTINGS 2. ADDITIONAL INFORMATION PER MECHANICAL, PLUMBING, ELECTRICAL AND CIVIL MIN 8" GREATER OF LAP SPLICE LENGTH AND 5 TIMES SPACING SPACING SHALL NOT EXCEED 6" WIRE TIES CONTACT SPLICE DETAIL BAR OFFSET 6 MIN 1 1d, (1" MIN), OR (4/3 AGGREGATE ⌀MIN) BAR CLEARANCE BEND AND HOOK DETAILS COLUMN TIES / BEAM STIRRUPS / CROSSTIES "d" "d " "d " HO O K 12 d , 9 0 ° 4d, (2 1/2" MIN) 45° RADIUS: 3d FOR BARS NOT OVER #8 4d FOR #9, #10 AND #11 BARS 5d FOR #14 AND #18 BARS RADIUS = 5d FOR ALL GRADE 40 BARS WITH 180° HOOK 6d (3" MIN) 135° BEND RADIUS: 2d FOR BARS NOT OVER #5 3d FOR #6, #7, AND #8 BARS 6d (3" MIN) FOR BARS NOT OVER #5 12d FOR #6, #7, AND #8 BARS CIRCULAR COLUMN / DRILLED PIER TIES STANDARD HOOK (90° MINIMUM BEND) AROUND VERTICAL -STAGGER HOOK LOCATIONS AS REQUIRED FOR SUCCESSIVE CIRCULAR TIES MINIMUM 6" OVERLAP "CLOSED""OPEN" 90° BEND 135° BEND 6d (3" MIN) NON-CONTACT SPLICE DETAIL CASE 1: CLEAR SPACING OF BARS BEING SPLICED IS NOT LESS THAN 1 BAR DIAMETER, CLEAR COVER IS NOT LESS THAN 1 BAR DIAMETER, AND TIES OR STIRRUPS ARE PRESENT THROUGHOUT THE SPLICE LENGTH NOT LESS THAN THE CODE MINIMUM OR THE CLEAR SPACING OF BARS BEING SPLICED IS NOT LESS THAN 2 BAR DIAMETERS AND CLEAR COVER IS NOT LESS THAN 1 BAR DIAMETER CASE 2: ALL OTHER CASES NOTE: TOP BARS, "T", ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE CAST BELOW THE BAR. OTHER BARS, "O", ARE ALL VERTICAL BARS AND HORIZONTAL BARS WITH LESS THAN 12" OF FRESH CONCRETE CAST BELOW THE BAR SPLICE LENGTH (INCHES) CASTING POSITION 0.375" 22 CLASS B TENSION LAP SPLICE TABLE #3 T O CASE 1 2 3000 PSI 4000 PSI 5000 PSI 6000 PSI 3000 PSI 4000 PSI 5000 PSI 6000 PSI 28 1925 1722 1620 3342 2837 2533 2330 0.500" 29 #4 T O 38 2533 2329 2127 4356 3749 3444 3140 0.625" 36 #5 T O 47 3141 2836 2633 5470 4761 4254 3850 0.750" 43 #6 T O 56 3749 3444 3140 6584 5673 5065 4659 0.875" 63 #7 T O 81 5471 4963 4558 94122 81106 7395 6786 1.000" 72 #8 T O 93 6281 5672 5166 107139 93121 83108 7699 1.128" 81 #9 T O 105 7091 6381 5774 121157 105136 94122 86111 1.270" 91 #10 T O 118 79102 7192 6484 136177 118153 106137 96125 1.410" 101 #11 T O 131 87114 78102 7193 151196 131170 117152 107139 BAR SIZE BAR DIAMETER 4500 PSI 2735 3647 4558 5369 77101 88115 100129 112145 124161 4500 PSI 1823 2431 3039 3647 6723 7752 8659 9767 83108 CORNER INTERSECTION CORNER BAR WIITH SAME SIZE AND SPACING AS HORIZONTAL REINFORCING ALTERNATE BENDS NO T E 1 NOTE 1 NO T E 1 NOTE 1 NOTE: CLASS "B" TENSION LAP SPLICE OR 24", WHICHEVER IS GREATER FREE END NOTE 1 BAR WITH SAME SIZE AND SPACING AS HORIZONTAL REINFORCING WITH STANDARD 90 DEG OR 180 DEG HOOK BAR WITH SAME SIZE AND SPACING AS HORIZONTAL REINFORCING ABBREVIATIONS ACI AMERICAN CONCRETE INSTITUTE ABC AGGREGATE BASE COURSE AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AFF ABOVE FINISH FLOOR AGG AGGREGATE AHJ AUTHORITY HAVING JURISDICTION AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALT ALTERNATE ARCH ARCHITECT OR ARCHITECTURAL DOCUMENTS ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY BP BASE PLATE BOD BOTTOM OF DECK CC CONCRETE COLUMN CB CONCRETE BEAM CALCS CALCULATIONS CJ CONTROL JOINT OR CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION WELD CLR CLEAR CMU CONCRETE MASONRY UNIT C COLUMN DEG DEGREE DIA, Ø DIAMETER DIM DIMENSION DL DEAD LOAD DN DOWN DP DRILLED PIER E MODULUS OF ELASTICITY EOD EDGE OF ROOF DECK EOS EDGE OF SLAB EOR ENGINEER OF RECORD EJ EXPANSION JOINT EL ELEVATION EQ EQUAL EXT EXTERIOR FD FLOOR DRAIN FFE FINISHED FLOOR ELEVATION FT FOOT (FEET) F FOOTING FY YIELD STRESS STEEL G GRATING GA GAGE OR GAUGE GB GRADE BEAM GSN GENERAL STRUCTURAL NOTES HP HIGH POINT HS HIGH STRENGTH HT HEIGHT I (IN4 )MOMENT OF INERTIA IBC INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL ID INSIDE DIAMETER IN INCH K KIP = 1000 LBS KSI KIPS PER SQUARE INCH L LEDGER LBS POUND(S) LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LSH LONG SIDE HORIZONTAL LSV LONG SIDE VERTICAL LT LINTEL LP LOW POINT MAX MAXIMUM MCJ MASONRY CONTROL JOINT MIN MINIMUM NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OPP OPPOSITE PCI PRESTRESSED CONCRETE INSTITUTE PC PILE/PIER CAP PCF POUNDS PER CUBIC FOOT PJP PARTIAL JOINT PENETRATION WELD PLF POUNDS PER LINEAR FOOT PSI POUNDS PER SQUARE INCH PT, P/T POST-TENSIONED PSF POUNDS PER SQUARE FOOT SDI STEEL DECK INSTITUTE SL SNOW LOAD SIB STRUCTURAL ISOLATION BREAK SIM SIMILAR SJI STEEL JOIST INSTITUTE SS STAINLESS STEEL STD STANDARD SW SHEARWALL TL TOTAL LOAD TOC TOP OF CONCRETE TODP TOP OF DRILLED PIER TOF TOP OF FOOTING TOS TOP OF STEEL TOW TOP OF WALL TYP TYPICAL UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE UT ULTRASONIC TESTING WP WORK POINT WWR WELDED WIRE REINFORCEMENT WF WALL FOOTING W WALL W/CM WATER-CEMENT RATIO X-STRONG EXTRA STRONG XX-STRONG DOUBLE EXTRA STRONG #NUMBER SHEET NUMBER 21 5 S o u t h S t a t e S t r e e t , S u i t e 4 0 0 | S a l t L a k e C i t y , U T 8 4 1 1 1 | T e l . N o . (3 8 5 ) 2 1 2 - 3 1 7 6 SEAL DR A W N B Y : DE S I G N E D B Y : CH E C K E D B Y : PRO J E C T No . : SC A L E : DE S C R I P T I O N DA T E # WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N SPRELIMINARYNOT FORCONSTRUCTIONAu t o d e s k D o c s : / / 0 9 6 3 6 0 0 1 0 W a s a t c h P e a k s R a n c h / W P R P ha s e 3 C B o o s t e r S t a t i o n ( R 2 4 ) . r v t As i n d i c a t e d S-010 DD PS JN 09 6 3 6 0 0 1 0 TY P I C A L D E T A I L S A N D AB B R E V I A T I O N S 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 SCALE: NTSS-010 T2 TYPICAL DETAIL - PLAN VIEW - REINFORCING IN CONCRETE FOOTING SCALE: NTSS-010 T5 TYPICAL DETAIL - UTILITY BELOW WALL FOOTING SCALE: NTSS-010 T1 TYPICAL DETAIL - CONCRETE REINFORCING BARS SCALE: NTSS-010 T7 TYPICAL DETAIL - CLASS "B" TENSION LAP SPLICE LENGTHS FOR UNCOATED GRADE 60 REINFORCING STEEL IN NORMAL WEIGHT CONCRETE SCALE: NTSS-010 T3 TYPICAL DETAIL - PLAN VIEW - REINFORCING IN CONCRETE WALLS SEALPRELIMINARYNOT FORCONSTRUCTION04/23/2025 NO T F O R CO N S T R U C T I O N ± 1 0 ' - 8 " 1' - 0 " ± 5 ' - 8 " 1' - 0 " 12' - 6" 101 6" 6" 6" TOF 6338' - 0"101 S-201 101 S-201 102 S-2015' - 0 " 103 S-201 103 S-201 101 S-201 102 102 102 103 S-201 DOWN 103 103 A. STRUCTURAL REFERENCE ELEVATIONS = 0’-0” (6341.58’) WHICH IS THE BOTTOM OF PRECAST CONCRETE BUILDING, VERIFY WITH CIVIL DRAWINGS/EXISTING DRAWINGS. ALL ELEVATIONS NOTED ON PLANS ARE WITH RESPECT TO REFERENCE DATUM ELEVATION/EXISTING INFORMATION UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE SITE AND LOCAL CONDITIONS. B. THE CIVIL FURNISHES ALL ELEVATIONS. RESOLVE ANY DISCREPANCY WITH ARCHITECT. NOTIFY KIMLEY-HORN THROUGH CIVIL OF ANY VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN BY THIS DRAWING. C. ALL OPENINGS THROUGH FLOORS, WALLS OR ROOF ARE NOT SHOWN ON PLANS. COORDINATE ALL OPENING LOCATIONS WITH PRECAST DRAWINGS, MECHANICAL, AND ELECTRICAL. COORDINATE ADDITIONAL FRAMING REQUIREMENTS OR REINFORCING WITH TYPICAL DETAILS. D. REFER TO SHEETS S-000 THRU S-001 FOR GENERAL STRUCTURAL NOTES, LEGENDS, AND SPECIAL INSPECTION REQUIREMENTS. E. REFER TO SHEET S-010 FOR TYPICAL DETAILS AND ABBREVIATIONS. TYPICAL DETAILS APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. TYPICAL DETAILS ARE NOT NOTED AT EACH LOCATION AT WHICH THEY ARE APPLICABLE. GENERAL FOUNDATION PLAN NOTES SHEET NUMBER 21 5 S o u t h S t a t e S t r e e t , S u i t e 4 0 0 | S a l t L a k e C i t y , U T 8 4 1 1 1 | T e l . N o . (3 8 5 ) 2 1 2 - 3 1 7 6 SEAL DR A W N B Y : DE S I G N E D B Y : CH E C K E D B Y : PRO J E C T No . : SC A L E : DE S C R I P T I O N DA T E # WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N SPRELIMINARYNOT FORCONSTRUCTIONAu t o d e s k D o c s : / / 0 9 6 3 6 0 0 1 0 W a s a t c h P e a k s R a n c h / W P R P ha s e 3 C B o o s t e r S t a t i o n ( R 2 4 ) . r v t As i n d i c a t e d S-101 DD PS JN 09 6 3 6 0 0 1 0 FO U N D A T I O N P L A N 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 S-101 SCALE: 3/8" = 1'-0" 1 FOUNDATION PLAN NORTH SHEET KEYNOTES 101 PRECAST CONCRETE BUILDING BY PRECAST MANUFACTURER. 102 LOCATION WHERE FINISHED GRADE ELEVATION EQUALS TOP OF WALL ELEVATION - FIELD VERIFY. 103 SEE CIVIL PLANS FOR PIPE ENCASING DETAILS. SEALPRELIMINARYNOT FORCONSTRUCTION04/23/2025 NO T F O R CO N S T R U C T I O N 6341.58' 6341.58' 6337.00' 6341.58' 3" C L R 2" C L R 3' - 0" FINISHED GRADE 1" ⌀WEEP HOLES AT 48" OC 2" C L R 6" PRECAST CONCRETE BUILDING ENGINEERED GRANULAR FILL 6" CONCRETE WALL WITH #4 AT 12" OC EACH WAY CENTERED #4 TRANSVERSE AT 12" OC 12" THICK CONCRETE FOOTING STANDARD 90° BEND (5) #4 CONTINUOUS (3 TOP 2 BOTTOM) 6" M I N I M U M PRECAST CONCRETE BUILDING ENGINEERED GRANULAR FILL PER GEOTECHNICAL REPORT 6" FINISHED GRADE 3" C L R FINISHED GRADE PRECAST CONCRETE BUILDING ENGINEERED GRANULAR FILL CONCRETE WALL - SEE DETAIL 101 FOR INFORMATION SHOWN BUT NOT NOTED C L R 1 1 / 2 " #4 AT 12" OC EACH WAY 3 " C L R #4 DOWEL AT 36" LONG AT 12" OC, CENTERED IN FOOTING DEPTH 6" CONCRETE WALL #4 NOSING BARS 6" #4 AT 12" OC EACH WAY 6" #4 DOWEL TO MATCH AND LAP WALL REINFORCING 8" S-201 104 STANDARD 90 DEG BEND 11" TYP 7" T Y P #4 AT 12" OC EACH WAY 6" CONCRETE WALL 6" 3" 6" FINISHED GRADE CONCRETE STAIRS STANDARD 90° BEND 12" THICK CONCRETE FOOTING #4 AT 12" OC EACH WAY CENTERED IN WALL 6" CONCRETE WALLENGINEERED GRANULAR FILL #4 AT 12" OC EACH WAY SHEET NUMBER 21 5 S o u t h S t a t e S t r e e t , S u i t e 4 0 0 | S a l t L a k e C i t y , U T 8 4 1 1 1 | T e l . N o . (3 8 5 ) 2 1 2 - 3 1 7 6 SEAL DR A W N B Y : DE S I G N E D B Y : CH E C K E D B Y : PRO J E C T No . : SC A L E : DE S C R I P T I O N DA T E # WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PL A T 3 C B O O S T E R P U M P S T A T I O N P L A N SPRELIMINARYNOT FORCONSTRUCTIONAu t o d e s k D o c s : / / 0 9 6 3 6 0 0 1 0 W a s a t c h P e a k s R a n c h / W P R P ha s e 3 C B o o s t e r S t a t i o n ( R 2 4 ) . r v t As i n d i c a t e d S-201 DD PS JN 09 6 3 6 0 0 1 0 FO U N D A T I O N D E T A I L S 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 04 / 1 7 / 2 0 2 5 SCALE: NTSS-201 101 CONCRETE WALL FOOTING SCALE: NTSS-201 103 PRECAST BUILDING ON ENGINEERED FILL SCALE: NTSS-201 102 CONCRETE STAIRS ON GRADE SCALE: NTSS-201 104 CONCRETE STAIRS ON GRADE SEALPRELIMINARYNOT FORCONSTRUCTION04/23/2025 NO T F O R CO N S T R U C T I O N E00 SI T E P L A N V I E W RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T ELECTRICAL DRAWING INDEX SHEET NO.DESCRIPTION COVERSHEETE00 POWER SINGLE-LINE DIAGRAME02 ENLARGED VIEW SITE PLANES102 SITE PLAN VIEWES101 WASATCH PEAKS RANCH MORGAN COUNTY, UTAH PHASE 3C BOOSTER PUMP STATION WASATCH PEAKS RANCH APPROVED FOR CONSTRUCTION SIGNATURE . NAME & TITLE . CONTRACTOR. APPROVED FOR CONSTRUCTION SIGNATURE . NAME & TITLE . KIMLEY-HORN- CIVIL APPROVED FOR CONSTRUCTION SIGNATURE . NAME & TITLE . SKM- CONTROLS / INSTRUMENTS APPROVED FOR CONSTRUCTION SIGNATURE . NAME & TITLE . NOTES, LEGENDS, SCHEDULESE01 ELECTRICAL DETAILSE03 ENLARGED VIEWES103 NO T F O R CO N S T R U C T I O N E01 SI T E P L A N V I E W RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T GENERAL NOTES COMBINATION VOICE/DATA RECEPTACLE SYMBOL POWER SYMBOLS LEGEND M VFD DATA RECEPTACLE VOICE RECEPTACLE POWER/COMMUNICATIONS POLE FOR WORKSTATION FURNITURE TV OUTLET, INCLUDES COAX & DATA VARIABLE FREQUENCY DRIVE METER J-BOX ELECTRIC MOTOR THERMAL SWITCH GROUND BUSS BAR TELEPHONE TERMINAL BOARD ELECTRICAL PANEL STARTER COMBINATION STARTER/FUSED DISCONNECT FUSED DISCONNECT SWITCH NON-FUSED DISCONNECT SWITCH SPECIAL PURPOSE RECEPTACLE - SINGLE PHASE SPECIAL PURPOSE RECEPTACLE - THREE PHASE FOURPLEX RECEPTACLE - GFCI FOURPLEX RECEPTACLE FLOOR BOX WITH 4-PLEX RECEPTACLE AND VOICE/DATA OUTLET FLOOR BOX WITH DUPLEX 120V RECEPTACLE HALF-SWITCHED DUPLEX RECEPTACLE DUPLEX RECEPTACLE - GFCI DUPLEX RECEPTACLE TWIST-LOCK RECEPTACLE 208/240V OVEN RECEPTACLE SIMPLEX RECEPTACLE DESCRIPTION TV J TRANSFORMERXFMR WEATHERPROOFWP UNDERGROUNDUG SURGE PROTECTED DEVICESPD TELEPHONE TERMINAL BOARDTTB TYPICALTYP TAMPER RESISTANTTR SURGE SUPRESSION.SS RIGID NONMETALLIC CONDUITRNC ROCKY MOUNTAIN POWERRMP REQUIREMENTSREQ OVER CURRENT PROTECTIONOCP ON CENTER(S)OC NIGHT LIGHTNL NOT IN CONTRACTNIC MAIN LUGS ONLYMLO RIGID METAL CONDUITRMC MINIMUM CIRCUIT AMPSMCA LIQUID-TIGHT NONMETAL CONDUITLFNC LIQUID-TIGHT METAL CONDUITLFMC KILOWATTSKW KILO VOLT AMPERESKVA ISOLATEDISO INSULATEDINS INTERMEDIATE METAL CONDUITIMC ISOLATED GROUNDIG HORSE POWERHP GROUND CONDUCTORGND FLEXIBLE METAL CONDUITFMC FULL LOAD AMPSFLA FIRE ALARM CONTROL PANELFACP FIRE ALARMFA EXISTINGE, EX ELECTRIC WATER COOLEREWC ELECTRIC NONMETALLIC TUBINGENT ELECTRIC METALLIC TUBINGEMT EMERGENCYEM COPPERCU CIRCUITCKT CIRCUIT BREAKERCB CONDUITC ALUMINUMAL AUTHORITY HAVING JURISDICTIONAHJ ABOVE FINISHED FLOORAFF ABBREVIATIONS ABOVE COUNTERAC AMP OR AMPSA ABBREV.DESCRIPTION MAIN CIRCUIT BREAKERMCB TYPE KP SECURITY SYSTEM KEYPAD CARD READER CEILING MOUNT SECURITY CAMERA ("TYPE" INDICATES TYPE OF CAMERA) SYMBOL MECHANICAL EQUIPMENT CALLOUT REVISION CALLOUT LIGHT FIXTURE CALLOUT OWNER PROVIDED EQUIPMENT CALLOUT KEYED NOTE WIRE CONDUIT - ALUMINUM WIRE CONDUIT - COPPER DETAIL CALLOUT CALLOUTS/NOTES LEGEND ELEVATION CALLOUT DESCRIPTION X X X XXX X XXX XXX XXX XXX X XXX HOME RUN TO PANELBOARD 1.REFER TO THE MECHANICAL SHEETS FOR THE EXACT LOCATION OF THE MECHANICAL EQUIPMENT. 2.ALL METALLIC CONDUITS, JOINTS, FITTINGS, ETC., IN CONTACT WITH THE GROUNDS SHALL BE SPIRALLY WRAPPED WITH 3M SCOTCHWRAP-51, 20 MIL TAPE (OR APPROVED EQUAL). 3.ALL UNDERGROUND CONDUIT SHALL BE BURIED 24" MINIMUM UNDER THE GROUND. 4.FLEXIBLE CONDUITS CAN ONLY BE USED FOR SHORT RUNS (6' MAXIMUM). 5. 6. 7. 8. SWITCHBOARDS, PANELBOARDS, AND MOTOR CONTROL CENTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT. (NEC 110-16). FOR 20 AMP CIRCUITS, USE NO. 10 THHN CONDUCTORS FOR CONDUCTOR LENGTH OVER 100 FEET, NO. 8 THHN OVER 200 FEET, NO. 6 THHN OVER 300 FEET AND NO. 4 THHN OVER 400 FEET. AIC RATINGS OF ALL OVERCURRENT PROTECTIVE DEVICES SHALL BE EQUAL TO OR GREATER THAN THE AIC RATING SHOWN IN THE PLANS. SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH CALCULATED MAXIMUM AVAILABLE FAULT CURRENT AND THE DATE IT WAS CALCULATED (NEC 110-24). CR ST CIRCUIT BREAKER ELECTRONIC TRIP CIRCUIT BREAKER FUSE DROP DUPLEX RECEPTACLE - GFCI DROP FOURPLEX RECEPTACLE - GFCI DOORBELL - EXTERIOR DB DOORBELL - INTERIOR CEILINGCLG TYPE WALL MOUNT SECURITY CAMERA ("TYPE" INDICATES TYPE OF CAMERA) MEDIA DISTRIBUTION UNITMDU BLANK FACE - GFCI ADA PUSHBUTTONl l DISHWASHERDW MW MICROWAVE DISPOSALDISP DRYERD REX REQUEST TO EXIT RC ROOM CONTROLLER PP POWER PACK PB PUSH BUTTON ML MAGNETIC LOCK ES ELECTRIC STRIKE DC DOOR CONTACTOR CORRIDORCORR WASHERW LIGHTINGLTG RECEPTACLESRCPT LEVELLVL ABBREVIATIONS AMPERAGE INTERRUPTING CAPACITYAIC SHORT CIRCUIT RATIOSCR NO T F O R CO N S T R U C T I O N TO UTILITY M 200A/3P "M-1" COMBO UTILITY METER 480V, 3PH, 200A MAIN, NEMA 3R G 12" GROUND ROD (S) TO ACHIEVE MIN. RESISTANCE OF 25 OHM AS PER NEC 250.52 UTILITY CO. XFMR 480V, 3ɸ, 3W, SECONDARY #2 AWG CU. TYP PANEL "MDP", 250A, 277/480V, 3ɸ, 3W, 25 KAIC FULLY RATED, NEMA 1. (PROVIDED AND INSTALLED BY OTHERS) 200A/3P SCR = 22,070A UFER GROUND AT PUMP HOUSE PAD ATS-1 200A, 277/480V, 3ɸ , 3POLE, 18 KAIC, NEMA 3R, OPEN TRANSITION, SURGE PROTECTOR AUTO TRANSFER SWITCH 125A,3P PROVIDE IN LEVEL 2 NOISE-REDUCING / WEATHERPROOF ENCLOSURE GEN-1 80KW GENERATOR SET G 12" GROUND ROD (S) TO ACHIEVE MIN. RESISTANCE OF 25 OHM AS PER NEC 250.52 #2 AWG CU. TYP UFER GROUND AT EQUIPMENT PADs (IF AVAILABLE) 43X 43X 43X TO P1 (1) 3" CONDUIT BY HUNT ELECTRIC CONDUCTORS BY UTILITY (1) 4" CONDUIT BY HUNT ELECTRIC CONDUCTORS BY UTILITY 40A/3P 40A/3P 40A/3P 40A/2P 15A/3P SCR = 20,326A SCR = 17,787A E02 PO W E R S I N G L E L I N E D I A G R A M RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T SCALE: NTS2ELECTRICAL GENERATOR CALCULATION NOTES: 1.THE DESIGN ELEVATION IS APPROXIMATELY 7000' AND GENERATOR HAS BEEN DE-RATED 2.5% FOR EVERY 1000 FT ABOVE 3500 FT. 2.ONLY (1) PUMP WILL OPERATE AT A GIVEN TIME. GENERATOR IS SIZED WITH ONLY (1) PUMP OPERATING 3.THERE WILL BE A SLIGHT DELAY IN BETWEEN EACH PUMP STARTING TO ACCOUNT FOR INRUSH / STARTING CURRENT 4.EACH PUMP WILL BE STARTED VIA A RVSS -6 PULSE THYRISTORS -LIMITING CURRENT OF APPROXIMATELY 300% FLA -RAMPED STARTING TIME UP TO 100% SPEED 1 2 3 4 5 KEYED NOTES PROVIDE (2) 1" CONDUITS FROM GENERATOR TO ATS FOR CONTROLS AND MONITORING. PROVIDE 208V/30A/1PH FOR GENERATOR BLOCK HEATER. PROVIDE 120V/20A/1PH FOR GENERATOR BATTERY CHARGER. PANEL MDP AND ALL PUMP HOUSE ELECTRICAL TO BE DESIGNED, PROVIDED AND INSTALLED BY OTHERS. HUNT ELECTRIC TO PROVIDE TERMINATIONS TO THE 200A MAIN BREAKER. PROVIDE (1) 1" CONDUIT FROM ATS TO GENERATOR REMOTE ANNUNCIATOR PANEL. ANNUNCIATOR PANEL TO BE LOCATED IN THE PUMP HOUSE. COORDINATE EXACT LOCATION PRIOR TO ROUGH IN. PROVIDE (1) 1" CONDUIT FROM ATS TO SKM CONTROL PANEL. VERIFY EXACT LOCATION OF CONTROL PANEL PRIOR TO ROUGH-IN. ALL NEW EQUIPMENT SHALL BE BONDED IN ACCORDANCE WITH ARTICLE 250 IN THE 2020 NEC. GENERATOR IS SIZED FOR ACTUAL OPERATING LOAD AND UTILITY IS SIZED FOR PEAK LOAD. 6 7 SIZE QTY SIZE GNDTYPEAMPCONDUCTORCOND 31 100 3 1 41 1 1/2"4 31X 120 3 1/0 41X 4 32X 135 3 2/0 42X 2"4 33X 155 3 3/0 43X 4 4/0318034X 42 1/2"44X 25032052"325 42 1/2"425 3503250335 43"435 4003270340 4440 50033103 1/2"350 4450 6 4 2 430 230 3"4 300 375 475 385 4"3 750 1 75044" 360 460 340 340 3 1/2" 4" 3 4 600 600 ALUMINUM CONDUCTOR & CONDUIT SCHEDULE 3/4"2 10 102030 COPPER CONDUCTOR & CONDUIT SCHEDULE 30 3 40 4 28 40 2 8 38 3 48 4 26 55 2 6 8 36 3 46 1"4 24 3/4"70 2 4 34 1"3 44 1 1/4"4 23 1"85 2 3 33 3 43 1 1/4"4 32 95 3 2 6 42 4 31 110 3 1 41 1 1/2"4 31X 150 3 1/0 41X 4 32X 175 3 2/0 42X 2"4 33X 200 3 3/0 43X 4 44/0323034X 42 1/2"44X 25032552"325 42 1/2"425 33503310335 43"435 4003335340 4440 50033803 1/2"350 4450 TYPE CONDUCTOR QTY GNDSIZESIZE CONDUIT PROT MAX 3/4"3 12 121320 3/4"2 12 121220 1 2 3 4 5 6 SCALE: NTS1POWER SINGLE LINE DIAGRAM SCALE: NTS3FAULT CURRENT CALCULATION 8 8 NO T F O R CO N S T R U C T I O N 9'-4"7'-0 " 8" 4' - 0 " 4' - 8 " 5'-0" 7'-0 " 6'-0 " 4'-0" 3' - 6 " 4.5" DIA. TERM-A-DUCTS 14 EA. 2' LONG GALV. UNISTRUT 2 EA. IN SHORT WALLS 2'-0" LONG GALV. UNISTRUT 4 EA. ON LONG WALLS 1/2" DIA. GROUNDING INSERTS 4 EA. 2.38" DIA. TERM-A-DUCTS 4 EA. 6.63" DIA. TERM-A-DUCTS 4 EA. REQ'D 3.51" DIA. TERM-A-DUCT TOP PCORP #7992600-SI # 1790023 4,622 LBS. BASE 8,400 LBS. 16" X 60" BLOCKOUT NO. 25P GALV. DIAMOND PLATE DOORS W/ LOCKING BOLTS2" X 4" X 24" PLASTIC LUMBER 2 EA. REQ'D FULL 180° OPEN (TYP) 2.4 - 25kV, 3-PHASE TRANSFORMER PADVAULT WITH ACCESS, STOCK ITEM 7992600- STOCK ITEM 1790023 2.4 - 25kV, 3-PHASE TRANSFORMER PADVAULT WITHOUT ACCESS, STOCK ITEM 7992601- STOCK ITEM 1790024 2.4 - 25kV, 3-PHASE TRANSFORMER PAD, STOCK ITEM 1790021 35kV, 3-PHASE TRANSFORMER PADVAULT WITH ACCESS, STOCK ITEM 7992602-STOCK ITEM 1008977 35kV, 3-PHASE TRANSFORMER PADVAULT WITHOUT ACCESS, STOCK ITEM 7992603- STOCK ITEM 1008975 35kV, 3-PHASE TRANSFORMER PAD, STOCK ITEM 1008958 E03 EL E C T R I C A L D E T A I L S RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T I-PC TYPE BOX II-PC III-PC 24 INCH "H" 24 24 25 INCH "L" 37-5/8 49-5/8 1-1/2 INCH "T" 1-1/2 2 16 INCH "W" 26 32-1/8 23-1/4 INCH "X" 35-5/8 47-5/8 13-3/4 INCH "Y" 24 30-1/8 2 INCH "Z" 3 3 SCALE: NTS2COMM BOX DETAIL SCALE: NTS1ROCKY MOUNTAIN POWER BARRIER POST DETAIL X Y PULL SLOT STAINLESS STEEL HEX HEAD BOLT W/ WASHER (TYPICAL PULL SLOT LOGO AREA L W H T NO T F O R CO N S T R U C T I O N SL 163+ 0 0 164+00 165+00 166 + 0 0 167+00 168+0 0 169+0 0 170+ 0 0 171+0 0 172+ 0 0 173+0 0 174+0 0 175+00 176+00 177+00 178+0 0 179+0 0 180 + 0 0 181+ 0 0 182+0 0 183+00 184+00 185+00 186+00 187+00 188+00 G68.47 AC G710.41 AC 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+0 0 21+00 22+00 23+0 0 24+00 25+00 26+00 27+00 28+00 29+00 163+ 0 0 164+00 165+00 166 + 0 0 167+00 168+0 0 169+0 0 170+ 0 0 171+0 0 172+ 0 0 173+0 0 174+0 0 175+00 176+00 177+00 178+0 0 179+0 0 180 + 0 0 181+ 0 0 182+0 0 183+00 184+00 185+00 186+00 187+00 188+00 (EXISTING)E-STA-173(EXISTING)COMM-173 XFMR-3CBP COMM-3CBP ES101 Feet 1:100 4002000100 Scale: 1" = 100' 3C BOOSTER PUMP STATION - SITE PLAN VIEW1 SI T E P L A N V I E W 1 ES102 RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T NO T F O R CO N S T R U C T I O N 173+ 0 0 174+0 0 173+ 0 0 174+0 0 (EXISTING) E-STA-173 (EXISTING) COMM-173 XFMR-3CBP COMM-3CBP ES102 Feet 1:5 151005 Scale: 1" = 5' 3C BOOSTER PUMP - ENLARGED SITE PLAN VIEW1 EN L A R G E D S I T E P L A N V I E W RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNT ELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T UTILITY XFMR EXTEND CONDUIT TO XFMR-3CBP TRANSFORMER VAULT. SEE PHASE 3C BACKBONE DRAWINGS. EXTEND CONDUIT TO COMM-3CBP.SEE PHASE 3C BACKBONE DRAWINGS. GENERATOR PAD (BY OTHERS) GENERATOR ATS MDP (1) 1" COMMS CONDUIT M-1 1 E03 2 E03 1 KEYED NOTES PROVIDE (2) 1" CONDUITS FROM GENERATOR TO ATS FOR CONTROLS AND MONITORING. PROVIDE 240V/30A/1PH FOR GENERATOR BLOCK HEATER. POWER TO BE FED FROM PANEL 'P-1' LOCATED IN PUMPHOUSE. PANEL 'P-1' TO BE PROVIDED BY OTHERS. PROVIDE 120V/20A/1PH FOR GENERATOR BATTERY CHARGER. POWER TO BE FED FROM PANEL 'P-1' LOCATED IN PUMPHOUSE. PANEL 'P-1' TO BE PROVIDED BY OTHERS. PANEL MDP AND ALL PUMP HOUSE ELECTRICAL TO BE DESIGNED, PROVIDED AND INSTALLED BY OTHERS. HUNT ELECTRIC TO PROVIDE TERMINATIONS TO THE 200A MAIN BREAKER. 2 3 1 2 3 4 4 NO T F O R CO N S T R U C T I O N ES103 Scale: 1" = 1' ENLARGED VIEW - 3C BOOSTER PUMPHOUSE1 EN L A R G E D V I E W RB 62 5 0 0 9 AS S H O W N HE DS (2410 SO.) PHONE - 801-975-8844 1863 W ALEXANDER ST. SALT LAKE CITY, UTAH 84119 DESIGN-BUILD SERVICES QUALITY, INTEGRITY, PERFORMANCE, & VERSATILITY HUNTELECTRIC, INC. FAX - 801-975-0509 WA S A T C H P E A K S R A N C H MO R G A N C O U N T Y , U T A H PH A S E 3 C B O O S T E R P U M P S T A T I O N 03 / 1 2 / 2 0 2 5 PR E L I M I N A R Y R E V I E W 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 05 / 1 6 / 2 0 2 5 PE R M I T S E T RAP MDP ATS M-1 1 KEYED NOTES PROVIDE (1) 1" CONDUITS FROM REMOTE ANNUNCIATOR PANEL TO ATS. COORDINATE EXACT LOCATION OF ANNUNCIATOR PANEL PRIOR TO ROUGH-IN. PROVIDE (1) 1" CONDUITS FROM SKM CONTROL PANEL TO ATS. VERIFY EXACT LOCATION OF CONTROL PANEL PRIOR TO ROUGH-IN. ROUTE 1" COMM CONDUIT TO CONTROL PANEL. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. PANEL MDP AND ALL PUMP HOUSE ELECTRICAL TO BE DESIGNED, PROVIDED AND INSTALLED BY OTHERS. HUNT ELECTRIC TO PROVIDE TERMINATIONS TO THE 200A MAIN BREAKER. ROUTE CONDUIT OVERHEAD FROM ATS TO MDP. COORDINATE BUILDING PENETRATION WITH CONTRACTOR. (1) 2" CONDUIT SCADA CONTROL PANEL 2 1 2 3 3 4 4 5 5 P-1 NO T F O R CO N S T R U C T I O N NO T F O R CO N S T R U C T I O N NO T F O R CO N S T R U C T I O N NO T F O R CO N S T R U C T I O N