Re: HF Sinclair Woods Cross Refining LLC (HF Sinclair) – Pretest Protocol for Carbon Monoxide
(CO), Carbon Dioxide (CO2), Flow, Nitrogen Oxides (NOx), Oxygen (O2), and Sulfur
Dioxide (SO2) Relative Accuracy Test – Davis County
The Utah Division of Air Quality (DAQ) reviewed HF Sinclair’s pretest protocol dated May 6, 2025.
The proposed test shall be performed under the following conditions:
HF Sinclair’s monitoring system to be certified:
Point Source Channel Manufacturer Model No. Monitor SN
FCCU
Unit 25
CO SICK MCS100E 15062323
NOx SICK MCS100E 15062323
O2/CO2 SICK MCS100E 15062323
SO2 SICK MCS100E 15062323
Alliance Technical Group will conduct a relative accuracy/performance specification test on HF
Sinclair’s FCCU Unit 25 continuous monitoring system.
Relative accuracy must be determined in the units of the emission standard or equivalent units of the
emission standard, i.e., tons/year shall be tested in pounds/hour or lb Hg/MM ton clinker 30-DRA
shall be tested as lb Hg/MM ton clinker.
6 Ü Ù Û Ù Û Þ
DAQC-523-25
Page 2
The DAQ understands that testing will be conducted as follows:
Test Date Point
Source Parameter EPA Reference Method
July 1, 2025 FCCU
Unit 25
CO, CO2, Flow, NOx, O2, &
SO2 1, 2, 3A, 4, 6C, 7E, and 10
• Reference Method 1 - Sample and Velocity Traverses for Stationary Point Sources as
outlined in 40 CFR 60 Appendix A shall be used to determine the location and number
of sampling points as applicable.
• Reference Method 2 - Determination of Stack Gas Velocity and Volumetric Flow Rate
– (Type S Pitot Tube) as outlined in 40 CFR 60 Appendix A.
• Reference Method 3A - Determination of Oxygen and Carbon Dioxide Concentrations
in Emissions from Stationary Point Sources – (Instrumental Analyzer Procedure) as
outlined in 40 CFR 60 Appendix A.
• Reference Method 4 - Determination of Moisture Content in Stack Gases as outlined in
40 CFR 60 Appendix A shall be used to determine the stack gas moisture content.
• Reference Method 6C - Determination of Sulfur Dioxide Emissions from Stationary
Point Sources - (Instrumental Analyzer Procedure) as outlined in 40 CFR 60 Appendix
A.
• Reference Method 7E - Determination of Nitrogen Oxide Emissions from Stationary
Point Sources - (Instrumental Analyzer Procedure) as outlined in 40 CFR 60 Appendix
A.
• Reference Method 10 - Determination of Carbon Monoxide Emissions from Stationary
Point Sources – (NDIR Instrumental Procedure) as outlined in 40 CFR 60 Appendix A.
• Deviations - The Director or the representative of the Director must be notified of and
approve deviations of the Reference Method test. Any deviation from these conditions
without approval from the DAQ may constitute rejection of these tests.
Acceptance of a protocol does not relieve the owner/operator and the testing contractor
from strict adherence to all applicable EPA methods, DAQ policies, Utah Air Quality
Rules (UAQR), and methods approved by the Director. Any deviation from EPA
methods, DAQ policies, UAQR, and methods approved by the Director must be
addressed separately and express written consent given prior to commencement of
testing.
• Field data (Point Source emission data and test data shall be given to the DAQ in a
timely manner for review.
DAQC-523-25
Page 3
• The Director will determine the relative accuracy of each monitoring system based on
Point Source continuous emission monitoring data and test data acquired by the staff
member of the DAQ during the test.
• All test reports must be submitted to the Director not later than 60 days after
completion of the test.
• The test report shall include all raw calibration data, raw emission data with date, time
stamps.
Relative accuracy test reports must contain:
1. Point source continuous monitor, channel, manufacturer, and serial number,
2. Raw stack test data and continuous monitor data with date and time stamps.
3. Emission data reported in concentration (ppm or %) and units in the applicable
emission limit.
The DAQ requires that all test reports include a statement signed by a responsible official
certifying that:
1. Testing was conducted while the Point Source was operating at the rate and/or
conditions specified in the applicable approval order, operating permit, or federal
regulation.
2. During testing, the Point Source combusted fuels, used raw materials, and maintained
process conditions representative of normal operations, and operated under such other
relevant conditions specified by the Director.
3. Based on information and belief formed after reasonable inquiry, the statements and
information contained in the report are true, accurate, and complete.