Loading...
HomeMy WebLinkAboutDERR-2025-003949~lflTANK ALUANCE. INC . May 14, 2025 Utah Department of Environmental Quality 195 North 1950 West Salt Lake City, Utah 84116 gaharris@utah.gov Dear Regulator: ~~~O\Yl~CID MAY 2 3 2025 Environmental Response & Remed iation Please find the attached copies of recent UST test results for the following locations: Site# Address Date of Test Test (s) performed Pilot# 0748 600 West 750 North, Willard UT 84340 4/22/25 Line Te st -emergency Facility# 0100590 County : Box Elder Official Test Report(s) Included If there has been a change in personnel, address or you do not require test reports to be sent, or if you would like for the reports to be emailed please let us know. Should you have any questions or require additional information at thi s time , please do not hesitate to call (614)923-0154. Thank you, ~f?~ Sue Pelphrey Special Projects Admin . Assist. US Tank Alliance, Inc. spelphrey@ustankalliance.com 7400SkylineDriveEast,SuiteA • Columbus ,OH 43235 • (614)923-0154 • Fax: (614)923-0111 www .ustankalliance .com SERVICE ORDER SUMMARY t'l:lTANK US TANK ALLIANCE. INC. 7400 Skyline Drive E., Suite A AL LIANC E, INC. Columbus, OH 43235 Phone: (614) 923-0154 Fax: (614) 923-0111 Customer: Location: Pilot Travel Centers, LLC Pilot# 0748 Attn: Joey Cupp Attn: Manager 5508 Lonas Road 600 West 750 North Attention: Environmental Department Facility# 0100590 Knoxville, TN 37909 Willard, UT 84340 Customer Phone: (865) 588-7488 ext. Facility Phone: (435) 723-1010 ext. Service Order# 0419874 Test Date: 4/25/2025 Invoice#: 0419874 Test Technician: Customer PO #: Test Purpose: EMERGENCY Disoatched For: EMERGENCY -Line lghtness Test -DSL. COMPLIANCE RETEST -Leak Detector Retest -DSL T3 . UST SYSTEM TESTING STAGE fl TESTING OTHER ACTIVITIES Tank □ Pressure Decay □ PVVentCap □ Helium Pin point Test LJ Line/LO/Impacts □ Healy □ Blockage □ Residential Tank Test □ Containment □ Air-to-Liquid □ GPM I Flow Rate □ ATG Certification □ Cath. Protect. □ Other Stage II □ CPSuNey □ Other Activities □ Notes/Comments: EMERGENCY -The DSL 22 Satellite Line Failed. rrhe DSL Lines (All, an d 22SAT) Passed. COMPLIANCE RETEST -The DSL T3 Mechanical Line Leak Detector Retest Passed. rrested by : Precision Testing Technolog ies, Inc . Tech: Max LaRou UT-412 . Other: Reviewed By: Andrew Beveridge EZY CHEK SYSTEMS TEST DATE 104/25/2025 ;~ fffe~~:f~o 15'•' PRODUCT LINE TESTER Testing Company Information ..:J ~ T+ :?" • DATA SHEET Name Precision Testinq Technoloqies, Inc. . I ""Systems & Train ing '1v J for the Address 2026 W. Elk Creek Crt. '-Petroleum Industry Facility ID# 0100590 Box Elder County City Bluffdale , UT Test Location Information Phone 801-886-9224 Name Flying J #7 48 Address 600 W 750 N Technican Information City Willard, UT Name Max Larou Phone 805-206-5269 Cert# UT-412 Contact Andrew Beveridge Applied Pressure 160 psi #1 Product Type: DSL (All, sans 22Sat.) #2 Product Type: DSL 22 Sat. TIME DATA -/+ GPL RES GPH TIME DATA -/+ GPL RES GPH 0 82 0 0.0037 0.0000 0.0000 0 70 0 0.0037 0.0000 0.0000 15 80.5 Ts 0.0037 0.0055 0.022~ ----0.088i 15 64 -6 0.003 7 0.0222 30 80 .5 -0-0.0037 0 0 --30 58 -6 0.0037 0 .0222 0 .088i ---- 0.0037 45 52 -6 0.0037 0 .0222 0 .088i -- 0 .0037 60 46 -6 0.0037 0.0222 0.088i -------- 0.0037 0.0037 -------- FINAL RESULT: PASS FINAL RESULT: FAIL #3 Product Type: #4 Product Type: TIME DATA -/+ GPL RES GPH TIME DATA -/+ GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 -------- 0.0037 0.0037 --------0.0037 0.0037 --------0.003 7 0.0037 -------- 0.0037 0.0 037 -------- 0.0037 0.0037 -------- FINAL RESULT: FINAL RESULT: #5 Product Type: #6 Product Type: TIME DATA -/+ GPL RES GPH TIME DATA -/+ GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 ------ 0.0037 0.0037 --------0.0037 0.0037 --------0 .0037 0.0037 -------- 0.0037 0.0 037 --------0.0037 0.0037 -------- FINAL RESULT : FINAL RESULT: ,. APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST Facility Name: Flyi nq J #7 48 owner: Pilot Travel Centers, LLC. Address: 600 W. 750 North Address: 5508 Lonas Road City, State , Zip Code : Willard, UT 84340 City, State, Zip Code: Knoxville , TN 37909 Facility I.D. #: 0100590 Box Elder County Phone#: (865) 588-7488 Testing Company: Prec ision Testing Technologies Inc . Phone #: 801-886-9224 Date : 04/25/2025 This data sheet can be used to test mechanical line leak detectors (MLLD) and electronic line leak detectors (ELLO ) with submersible turbine pump (STP ) systems. See PE I/RP1200, Sections 9.1 and 9.2 for test procedures. Line Number 3 Product Sto red DSL Leak Detector Manufactu rer VR Leak Det ecto r Model FX1DV Type of Le ak Detector IZI MLLD □MLLD □MLLD □MLLD □M LLD □MLLD □ELLD □ELLD □ELLD □ELLD □E L LD □ELLD MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) STP Full Operating Pressure 38 Che ck Valve Ho lding Pressure 30 Line Resiliency (ml) (li ne bleed back vol- ume as measured from check va lve hold -300 ing pre ss ure to zero psig) Step Th roug h Time in Second s (time the MLLD hes itates at mete ring pressure befo re going to full operating pressure 1 as measured from 0 psig wi t h no leak induced on the line) Metering Pressure (STP pressure when 18 simulated leak rate 3 gph at 10 ps ig) Opening Time in Seconds (the time the MLLD opens to allow fu ll pressure afte r 4 simulated leak is stopped ) Doe s the STP pressu re remain at or below the metering pressure for at least ~Yes □No □Yes □ No □Yes □ No □Yes □ No □Yes □ No □Yes □ No 60 seconds whe n the simulated leak is induced? Do es the leak detector reset (trip) when IZI Yes □No □Yes □No □Yes □No □Yes □No □Yes □No □Yes □No the line pressure is bled off to zero psig? Does the STP properly cycle on/off under ~Yes □No □Yes □No □Ye s □N o □Yes □No □Yes □No □Yes □No normal fuel system operation co nd itions? A "No" answe r to ei t her of the above questions indicates the MLLD fa ils the test. ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) STP Fu ll Op erating Pressure How many test cycles are observed before alarm/shutdown occu rs? Do es the simulated leak ca use an ala rm ? □Ye s □No □Yes □ No □Yes □ No □Yes D No □Yes □ No □Yes □ No A "N o" answer to the above question ind i- cates the ELLD fa ils the test. Does the simulated leak cause an STP □Yes □ No □Yes □ No □Yes □ No □Yes □ No □Yes □No □Yes □ No shutdown? □NA □NA □NA □NA □NA □NA Test Results 121 Pass □ Fail □Pass □Fail □P ass □ Fail D Pass □ Fail □Pass D Fail □ Pas s □ Fail Comments: Tester 's Name Max Larou UT-412 Tester 's Signature ~La,,,{!Bu