Loading...
HomeMy WebLinkAboutDDW-2025-004767Capacity calculation sheet Page 1 of 5/20/2025 Division of Drinking Water Water System Capacity Calculation Sheet— no - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - yes - - - - - - - - - - - - - - - - - - - - > > > - - - > > > - - - > > > - - - > > > - - - > > > (Last Update 3/30/2017) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 107% gpd/ERC Total (gpm)Gallons/ERC Total (gallons) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 393.4 870.0 381,114 *Enter the green cells only* Veyo Culinary Water Association 27019System Name System Number per residential connection other connections flow duration 1.1 Indoor Water Use 1.2 Outdoor Water Use 1.3 Fire Flow Water Use 2. Summary of Water System Capacity Requirements Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - Number of other connections - - - ERCs of other connections Total Equivalent Residential Connections (ERCs) Source Storage Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation Percentage of Residential ERCs using DW for irrigation Average irrigated acreage Total irrigated acreage of (park, school, etc.) Irrigation zone Source Storage Does the water system provide fire protection? Maximum fire demand (in gpm) for or Maximum fire suppression (in hours) for or Required Fire Suppression Storage (in gallons) - - - - - - - - 280 39 55.0 299 0.15 1.00 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) 5 Enter notes here, e.g. fire official contact info or comments.) (Example: water use of 2 factories equals to water use of 55 homes.) 335.0 MIN. REQUIREMENTS FOR INDOOR WATER USE MIN. REQUIREMENTS FOR IRRIGATION USE 60,000 MINIMUM REQUIREMENTS FOR WATER SYSTEM Source Storage None 221.2% 800 400 976 612 1,776 1,012 186.1 134,000 207.2 187,114 393.4 381,114 Map Zones 1 2 3 4 5 6 water system pressure zone water system pressure zone 1,000 1 (*Verify req'd fire flow and duration with local fire code officials.* (indoor + outdoor)(indoor + outdoor + fire) 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity gpm Existing Source Capacity gpm Source Capacity Deficit gpm Existing % of Total Req'd 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage gal This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Capacity calculation sheet Page 2 of 5/20/2025 Existing Storage Capacity gal Storage Capacity Deficit gal gal Is storage deficiency solely due to fire storage? Existing % of Total Req'd w/ flush toilets w/o flush toilets w/ flushometer valves 770,000 60,000 MINIMUM REQUIREMENTS FOR INDOOR USE 60 0 30 0 20 0 10 0 5 0 2.5 0 N/A 100 N/A 50 7 3.5 8.8 Total Existing Source Capacity (in gpm) Total Projected ERCs Total Existing Storage Cap. (in gallons) None Not Applicable 202.0% Modern Recreation Camp 0.00 0.0 Semi-Developed Camp 0.00 0.0 Semi-Developed Camp 0.00 0.0 RV Park 0.13 0.0 Roadway Rest Stop 0.0 870 280 770,000 Required Fire Storage (See R309-510, Tables 510-1, 2, & 4 for other facility types.) Number of people per camp site 3. Transient PWS Indoor Water Use ERC Calcuation 4. Data Input for Calculating ERCs, Source and Storage — Source Storage Facility Type Source Storage GPD/person*GPD/site or pad Gallons/person Gallon/siteor pad ERC/site or pad (GPD/vehicle)(Gal./vehicle) ERC/1000 vehicles served Vehicles served/day Residential Connections Obligated ERCs Total # of sites/pads ERCs ERCs Existing Future 0 0 0 0 0 0 WS001 370 WS002 Well #1 500 280 2 ST002 Brookside#1 Tank 50,000 ST003 Brookside#2 Tank 50,000 ST004 Green(Beer) Tank 50,000 ST007 Cottam Road Tank 500,000 ST009 120K Stell Bolted Tank 120,000 Veyo Spring 4.2 Summary - Existing Sources 4.1 Projected ERCs Calculation (optional) 4.3 Summary - Existing Storage Tanks (enter in green cells below) (enter below) (enter below) Veyo Culinary Water Association Maximum ERCs (assuming indoor use only)1566