Loading...
HomeMy WebLinkAboutDERR-2025-003881Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name UINTAH COUNTY Address 152 E 100 N VERNAL, UT 84078 Contact UINTAH COUNTY Phone Email dbrookens@uintah.utah.gov TANK LOCATION Name UINTAH COUNTY COURTHOUSE & JAIL Address 152 E100 N VERNAL, UT 84078 A Operator CONNOR KINGSTON Phone (435) 781-6757 B Operator SAME Phone SAME Facility ID: 9000325 Inspection Date: 05/19/2025 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST TANK DETAILS Tank ID/Alt ID 4 / 4 E-Gen/AST Yes / No Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc March 15, 1996 / 560 / Single - Separate excavation Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG Veeder Root / TLS-450 CSLD No Manifold LTT Test None LLD Test None Pipe Material-Mod Copper / None Pipe type/STP Cont Safe Suction / No STP Flex Connectors Not Listed LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankATG PipeLDDeferred CP Tank Test April 26, 2022 CP Pipe Test None INSPECTION COMMENTS None 2025-05-23 Page 1 of 3 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?Yes Is the site unmanned?No Cathodic Protection The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? No Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 4 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank has an overfill device?Yes If an overfill alarm is being used is it properly located so the delivery driver can hear or see it, and is clearly identified? Yes Tank 4 ATG/IM ATG/IM - Records on site document that the system is properly installed, calibrated, operated, and maintained (system and tank setup reports, maintenance records)? Written documentation of calibration, maintenance, and repair is kept for at least one year after work is completed? Yes ATG/IM - ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational? Yes ATG/IM - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes ATG - The tank was filled to at least the minimum level required to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits? Yes Tank 4 ATG/IM Does the ATG system have a valid annual test?Yes Tank 4 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 4 Suction Piping Leak Detection Piping qualifies as Safe Suction. (Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. If all these criteria are met, no leak detection is required on the piping.) Yes Tank 4 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes 2025-05-23 Page 2 of 3 Prepared by fueloperator.com DISPENSER RESPONSES MONTHLY LEAK DETECTION MONITORING May '24 Jun '24 Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24 Jan '25 Feb '25 Mar '25 Apr '25 Tank 4 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS FACILITY No Photos Question:The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? Comments:None Inspection Information Inspector:Perdue, Laura Record Created:May 23, 2025, 1:52 p.m. Inspection Date:May 19, 2025 2025-05-23 Page 3 of 3