DERR-2024-005665
VacuTect Tank Tightness Test page 1 of 1 Work Order:2364469 Date:3/14/2024 Site Name/ID:WALMART #WM5270 Address:629 N STATE ST City:LINDON State:UT Zip:84042 Tank Information Customer Tank ID Regulatory Tank ID Product Category Product Name Gallons Capacity Tank Type Tank Walls Compartmentalized Siphon Tank Vents included with test Test Start Time Test End Time Water ingress (Y/N) Bubble ingress (Y/N) Ullage ingress (Y/N) Test Result (P/F/I) 1 RUL 1 Gasoline - Regular RUL 19782 Fiberglass Doublewall (factory) No Yes with this tank 10:11:00 11:50:00 No No No Pass 2 RUL 2 2 Gasoline - Regular RUL 2 11904 Fiberglass Doublewall (factory) Yes Yes with this tank 10:11:00 11:50:00 No No No Pass 3 PREMIUM 3 Gasoline - Premium PREMIUM 7901 Fiberglass Doublewall (factory) Yes No with other tank 12:18:00 13:46:00 No No No Pass 4 Low Sulfur Diesel 4 Diesel Low Sulfur Diesel 10420 Fiberglass Doublewall (factory) No No with this tank 12:18:00 13:46:00 No No No Pass Yes - Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281. No - diagnostic only Technician Comments : UT151 Technician Name David Mathie Certification #41448 exp: 10/20/2025 Technician Signature Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin,TX. All rights reserved. tanknology.com Product Line Tightness Test Page 1 of 1 Work Order: 2364469 Date: 3/14/2024 Site Name/ID: WALMART #WM5270 / WM5270 Address: 629 N STATE ST City: LINDON State: UT Zip: 84042 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 RUL Pressure 60 10:33 11:33 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 RUL 2 Pressure 60 11:49 12:49 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 PREMIUM Pressure 10:33 11:33 0.00 Pass Yes Tank # 3 Line # 2 TLD-1 3 PREMIUM Pressure 60 11:49 12:49 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4 Low Sulfur Diesel Pressure 60 10:33 11:33 0.00 Pass Yes Tank # 4 Line # 2 TLD-1 4 Low Sulfur Diesel Pressure 60 11:49 12:49 0.00 Pass Yes Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WALMART #WM5270 629 N STATE ST LINDON UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE AR 72716 479-204-3407 03/14/2024 RUL RUL 2 Low Sulfur DieselVeeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLDDPLLDDPPLDDPLLDDPLLD 40 2 40 2 2 30 32 2 UT151 David Mathie NW1-2364469 PREMIUM T1:1 T2:1 T3:1 T4:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2364469 Date:3/14/2024 Site Name/ID:WALMART #WM5270 Address:629 N STATE ST City:LINDON State:UT Zip:84042 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 85 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 85 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WALMART #WM5270 SAM'S CLUB 629 N STATE ST LINDON UT 84042 WM5270 Tanknology, Inc. 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE AR 72716 479-204-3407 800-964-1250 03/14/2024 1 2 3 4 RUL RUL2 PREM DSL VR450 PLUS VR450 PLUS VR450 PLUS VR450 PLUS 19782 11904 7901 10420 119.4 119.4 119.4 119.4 UT151 David Mathie 629 N STATE ST WALMART #WM5270 629 N STATE ST, LINDON, UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE, AR 72716 479-204-3407 03/14/2024 ANNULAR ANNULAR ANNULAR STP STP STP STP RUL RUL2/PREM DSL RUL RUL2 PREM DSL UT151 David Mathie 629 N STATE ST WALMART #WM5270 629 N STATE ST, LINDON, UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE, AR 72716 479-204-3407 03/14/2024 UDC UDC UDC UDC UDC UDC UDC 1/2 3/4 5/6 7/8 9/10 11/12 13/14 UT151 David Mathie 629 N STATE ST WALMART #WM5270 629 N STATE ST, LINDON, UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE, AR 72716 479-204-3407 03/14/2024 UDC 15/16 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :WALMART #WM5270 Name :TANKNOLOGY INC. Address :629 N STATE ST LINDON, UT 84042 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :-Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :16 Products per Nozzle :3 Tanks Manifolded ?Yes Drop-Out tank present?NO Total # of Tanks Tested :3 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 1 RUL 19782 14929 4853 2 RUL 2 11904 7659 4245 3 PREMIUM 7901 4960 2941 14:49 2.00 2.00 1.99 1.99 1.98 1.98 1.92 Pass Total 39587 27548 12039 All 14:49 2.00 2.00 1.99 1.99 1.98 1.98 1.92 Pass Comments: Tester :David Mathie Test Date :3/14/2024 Signature :Work Order :2364469 WO: 2364469 PVVC tested ==>GAS Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>Husky Model Number ==>5885 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 9 0.0191 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.51 Pass Neg Leak Rate (CFH)0.21 18 0.0382 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.42 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0191 Total -ve LR: 0.0382 Test Date 3/14/2024 Technician Name David Mathie WO #2364469 Facility Name / Loc #WALMART #WM5270 WM5270 Street 629 N STATE ST City, St, Zip LINDON, UT 84042 Pressure Vacuum Vent Cap Test Form TP-201.1E Stage I Vapor System Survey Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories Survey Date 3/14/2024 Work Order 2364469 Cust Name / Location Number WM5270 Street Address 629 N STATE ST City, State, ZipCode LINDON UT 84042 Product Stage I Type Drop Tubes Type Drop Tubes Max inches from tank Bottom Fill Adapters Type Vapor Adapters Type NESHAP Work Required? Vent Caps Type Labeled Positive Cracking Pressure Labeled Negative Cracking Pressure 1 RUL Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No GAS Pressure Vacuum cap 3 8 2 RUL 2 Dual Point Straight w/ Flapper 5.00 Swivel Swivel (poppet) No 3 PREMIUM Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No Describe Work Required Surveyed by Signature WALMART #WM5270 629 N STATE ST LINDON, UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 479-204-3407 800-800-4633 03/14/2024 RUL 1 19782 118.375 OPW RUL2 2 11904 118.375 OPW PREM 3 7901 118.375 OPW DSL 4 10420 118.375 OPW UT151 David Mathie 2001 S.E. 10TH STREET BENTONVILLE, AR 72716 64 161.75 10420 95.75 10420 9148 87.8 Site ID/ Name: Address: WM5270 WALMART #WM5270 NW1-2364469 03/14/2024 629 N STATE ST, LINDON, UT 84042 Tank ID:4(Low Sulfur Diesel) 62.75 164.25 11904 99.5 11904 10789 91 Site ID/ Name: Address: WM5270 WALMART #WM5270 NW1-2364469 03/14/2024 629 N STATE ST, LINDON, UT 84042 Tank ID:2(RUL 2) 63.25 162 7901 96.75 7901 6913 87.5 Site ID/ Name: Address: WM5270 WALMART #WM5270 NW1-2364469 03/14/2024 629 N STATE ST, LINDON, UT 84042 Tank ID:3(PREMIUM) 65.75 166.75 19782 99 19782 17781 89.4 Site ID/ Name: Address: WM5270 WALMART #WM5270 NW1-2364469 03/14/2024 629 N STATE ST, LINDON, UT 84042 Tank ID:1(RUL) Tank ID: Sam's Club Emergency Stop (E-Stop / ESO) Periodic Inspection Facility Information Technician Information Site #: WM5270 Date: 3/14/2024 Address: 629 N STATE ST Name: David Mathie City / State: LINDON UT Technician Signature: SITE DATA 1 Number of E-Stop switches INSIDE the building: 1 2 Number of E-Stop switches OUTSIDE the building: 2 3 Call Alarm Central at 479-273-4600 a.Press 1 for Alarm Central b.Then press 4 for Technician c.Tell the operator you want the Sam's Club / Wal-Mart Gas Station account for club membership WM5270 put on test. d.They will ask for a password which is: 9350. e.Record the Alarm Central persons name and the time that you spoke to them(Pre Alarm) NOT 11:00:00 PERFORMANCE DATA Yes No NA 4 You have added or confirmed that all E-Stop locations are on the Site Diagram 5 Do all E-Stops shutdown power to ALL DISPENSERS 6 Do all E-Stops shutdown power to ALL STP's 7 Are ALL E-Stops clearly Labeled 8 Are the TURBINE BREAKERS clearly identified / labeled POST TEST 9 All equipment secured and any access ports, lids, enclosures are closed. 10 All safety barricades and test equipment has been properly removed 11 E-Stop was reset and all dispensing functions are normal 12 Call Alarm Central at 479-273-4600 a.Ask if Alarm was Received and if Yes, advise that testing is complete b.Record the Alarm Central persons name and the time that you spoke to them(Post Alarm) E-Stop Inspection Results PASS FAIL INCONCLUSIVE Comments ESTOP OUTSIDE BY DOOR TO KIOSK NOT CONNECTED TO ALARM CENTRAL YET WO: 2364469 ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 3/14/2024 UST Facility Person Conducting Test Facility Name WALMART #WM5270 Facility ID # WM5270 Tester's Name DMATHIE Physical Address 629 N STATE ST Company Tanknology Inc. City LINDON County UTAH State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner SAM'S CLUB Tester's Signature Date 3/14/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:1 RUL - 1 Y Y Y Y N Pass STP:2 RUL 2 - 1 Y Y Y Y N Pass STP:3 PREMIUM - 1 Y Y Y Y N Pass STP:4 Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2364469 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2364469 Site ID / Name:WM5270 / WALMART #WM5270 Address:629 N STATE ST City:LINDON State:UT Zip:84042 W.O.# NW1-2364469 Cust Ref#: 38227303 OVF WALMART #WM5270 629 N STATE ST LINDON UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE AR 72716 479-204-3407 12/14/2023 FRP 45 22 32 1246 32 1346 1 HR 0 FRP 45 21 31 1246 31 1346 1 HR 0 FRP 43 24 31 1246 31 1346 1 HR 0 FRP 43 24 30 1246 30 1346 1 HR 0 Tank 1 STP Sump 1 Tank 2 STP Sump 1 Tank 3 STP Sump 1 Tank 4 STP Sump 1 UT151 David Mathie NW1-2364464 WALMART #WM5270 629 N STATE ST LINDON UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE AR 72716 479-204-3407 12/14/2023 FRP 16.5 7 11 1259 11 1359 1 HR 0 FRP 16.5 7 11 1259 11 1359 1 HR 0 FRP 16.5 7 11 1259 11 1359 1 HR 0 FRP 16.5 7 11 1259 11 1359 1 HR 0 FRP 16.5 7 11 1259 11 1359 1 HR 0 1/2 3/4 5/6 7/8 9/10 11/12 FRP 16.5 7 11 1259 11 1359 1 HR 0 UT151 David Mathie NW1-2364464 WALMART #WM5270 629 N STATE ST LINDON UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE AR 72716 479-204-3407 12/14/2023 FRP 16.5 7 11 1259 11 1359 1 HR 0 FRP 16.5 7 11 1259 11 1359 1 HR 0 13/14 15/16 UT151 David Mathie NW1-2364464 WALMART #WM5270 629 N STATE ST LINDON, UT 84042 WM5270 Tanknology, Inc. SAM'S CLUB 479-204-3407 12/14/2023 2001 S.E. 10TH STREET DEPT. # 449562 BENTONVILLE, AR 72716 1 RUL 5 OPW 2 RUL2 5 OPW 3 PREM 5 OPW 4 DSL 5 OPW 15 WC 1303 15 WC 1308 5 MIN 0 15 WC 1312 15 WC 1317 5 MIN 0 15 WC 1321 15 WC 1326 5 MIN 0 15 WC 1350 15 WC 1355 5 MIN 0 UT151 David Mathie W.O.# NW1-2364464 Cust Ref#: 38227303 ANN W.O.# NW1-2364464 Cust Ref#: 38227303 LINE W.O.# NW1-2364464 Cust Ref#: 38227303 OVF Underground Storage Tank Inspection Verification Form Facility ID:1000995 Owner Name:WALMART INC.Facility Name:WALMART SUPERCENTER FUELING STATION # Owner Address:2101 SE SIMPLE SAVINGS DR Street Address:585 NORTH STATE STREET BENTONVILLE, AR 72716 LINDON, UT 84042 Operator A:SUZANNE NEVES / (435) 630-0320 / 1/19/2027 Operator B:CAROLYN AGNITA JONES / (270) 922-9381 / 1/19/2027 Owner Email:Sara.Gallien@walmart.com UTM Coordinates X/Y:437849 / 4466690 Disp ID/Alt ID Substance UDC Pipe Flex Loc Install Date UDC Install Date Fire Valve Sat Present UDC Test Disp Flex CP Test 1 - 1/2 Gas/Diesel Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 2 - 3/4 Gas/Diesel Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 3 - 5/6 Gasoline Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 4 - 7/8 Gasoline Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 5 - 9/10 Gasoline Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 6 - 11/12 Gasoline Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 7 - 13/14 Gas/Diesel Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 8 - 15/16 Gas/Diesel Yes Direct Flex Piping in Sump no Steel Flex 12/12/2023 12/12/2023 Yes No 12/14/2023 Tank ID/Alt ID:1 / 1 EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:9/11/2023 / 20000 / LLD Model: Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:Yes / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / LTT / ALD ATG Specs: / / Liquid Status STP Sump Test:12/14/2023 Spill Bk Test: ATG Test:3/14/2024 Overfill Test:3/14/2024 LTT Test:3/14/2024 LLD Test:03/14/2024 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:2 / 2a EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / Yes PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:9/11/2023 / 12000 / LLD Model: Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:No / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / LTT / ALD ATG Specs: / / Liquid Status STP Sump Test:12/14/2023 Spill Bk Test: ATG Test:3/14/2024 Overfill Test:3/14/2024 LTT Test:3/14/2024 LLD Test:03/14/2024 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:3 / 2b EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / Yes PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:9/11/2023 / 8000 / LLD Model: Substance Stored:Gasoline / Premium Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:No / 3/25/2024 Page 1 of 2 ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / LTT / ALD ATG Specs: / / Liquid Status STP Sump Test:12/14/2023 Spill Bk Test: ATG Test:3/14/2024 Overfill Test:3/14/2024 LTT Test:3/14/2024 LLD Test:03/14/2024 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:4 / 3 EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:9/11/2023 / 10000 / LLD Model: Substance Stored:Diesel / Diesel #1 Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - PST Fund/Other Type:No / ATG:Veeder Root / Tank/Pipe Rel Det:Interstitial DW / LTT / ALD ATG Specs: / / STP Sump Test:12/14/2023 Spill Bk Test: ATG Test:3/14/2024 Overfill Test:3/14/2024 LTT Test:3/14/2024 LLD Test:03/14/2024 CP Tank Test:CP Pipe Test: 3/25/2024 Page 2 of 2 Sara Gallien Walmart Inc 2101 SE Simple Savings Dr Bentonville, AR 72716 Re: Notice of approval to remove delivery prohibition tag Walmart Supercenter Fueling Station #5270 585 North State Street, Lindon Utah 84042 #1000995 Dear Sara Gallien: The Division of Environmental Response and Remediation has received all the documentation necessary to issue the attached certificate of compliance for the 20,000-gallon Regular, 12,000-gallon Regular, 8000-gallon Premium and 10,000-gallon Diesel tanks at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(6). Please remove and discard any tags that were attached to the fill for these tanks during installation. If you have additional questions, please contact the Project Manager identified on the red tag at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation Enclosure(s): cert. of compliance cc: United States Environmental Protection Agency Washington, DC 20460 Approval expires 04/30/24 OMB No.2050-0068 Notification for Underground Storage Tanks Implementing Agency Name And Address:IMPLEMENTING AGENCY USE ONLY ID NUMBER: DATE RECEIVED: TYPE OF NOTIFICATION DATE ENTERED INTO COMPUTER: A. NEW FACILITY OR ONE-TIME NOTIFICATION (previously deferred system) B. AMENDED C. CLOSURE OR CHANGE-IN- SERVICE DATA ENTRY CLERK INITIALS: OWNER WAS CONTACTED TO CLARIFY RESPONSES, COMMENTS: _____ Number of tanks at facility _____ Number of continuation sheets attached What USTs Are Included?An UST system is defined as any one or combination of tanks that is used to contain an accumulation of regulated substances, and whose volume (including connected underground piping) is 10 percent or more beneath the ground. Regulated USTs store petroleum or hazardous substances (see What Substances Are Covered below). This includes UST systems with field-constructed tanks and airport hydrant fuel distribution systems. What Tanks Are Excluded From Notification (see § 280.10 and § 280.12)? x Tanks removed from the ground before May 8, 1986; x Farm or residential tanks of 1,100 gallons or less capacity storing motor fuel for noncommercial purposes; x Tanks storing heating oil for use on the premises where stored; x Septic tanks; x Certain pipeline facilities regulated under chapters 601 and 603 of Title 49; x Surface impoundments, pits, ponds, or lagoons; x Storm water or wastewater collection systems; x Flow-through process tanks; x Liquid traps or associated gathering lines directly related to oil or gas production and gathering operations; x Tanks on or above the floor of underground areas, such as basements or tunnels; x Tanks with a capacity of 110 gallons or less; x Wastewater treatment tank systems; x UST systems containing radioactive material that are regulated under the Atomic Energy Act of 1954; x UST systems that are part of an emergency generator system at nuclear power generation facilities regulated by the Nuclear Regulatory Commission under 10 CFR part 50. What Substances Are Covered?The notification requirements apply to USTs containing petroleum or certain hazardous substances. Petroleum includes gasoline, used oil, diesel fuel, crude oil or any fraction thereof which is liquid at standard conditions of temperature and pressure (60 degrees Fahrenheit and 14.7 pounds per square inch absolute). Hazardous substances are those found in Section 101 (14) of the Comprehensive Environmental Response, Compensation and Liability Act of 1980, with the exception of those substances regulated as hazardous waste under Subtitle C of the Resource Conservation and Recovery Act. When And Who To Notify?Owners who bring USTs into use after May 8, 1986 must submit this notification form to the implementing agency within 30 days of bringing the UST into use. If the implementing agency requires notification of any amendments to the facility, send information to the implementing agency immediately. Penalties:Any owner who knowingly fails to notify or submits false information shall be subject to a civil penalty not to exceed $16,000 for each tank for which notification is not given or for which false information is given. INSTRUCTIONS AND GENERAL INFORMATION Please type or print in ink. Also, be sure you have signatures in ink for sections VIII and XI. Complete a notification form for each location containing underground storage tanks. If more than 5 tanks are owned at this location, you may photocopy pages 3 through 6 and use them for additional tanks. The primary purpose of this notification form is to provide information about the installation, existence, changes to, and closure of underground storage tank systems (USTs) that store or have stored petroleum or hazardous substances. The information you provide will be based on reasonably available records, or in the absence of such records, your knowledge or recollection. Federal law requires UST owners to use this notification form for all USTs storing regulated substances that are brought into use after May 8, 1986, or USTs in the ground as of May 8, 1986 that have stored regulated substances at any time since January 1, 1974. The information requested is required by Section 9002 of the Solid Waste Disposal Act (SWDA), as amended. Who Must Notify?40 CFR part 280, as amended, requires owners of USTs that store regulated substances (unless exempted) to notify implementing agencies of the existence of their USTs. Owner is defined as: x In the case of an UST in use on November 8, 1984, or brought into use after that date, any person who owns an UST used for storage, use, or dispensing of regulated substances; or x In the case of an UST in use before November 8, 1984, but no longer in use on that date, any person who owned the UST immediately before its discontinuation. Also, owners of previously deferred UST systems with field- constructed tanks and airport hydrant fuel distribution systems in the ground as of October 13, 2015 must submit a one-time notification of existence by October 13, 2018. Owners of UST systems with field- constructed tanks and airport hydrant fuel distribution systems brought into use after October 13, 2015 are considered new facilities and must follow the same notification requirements as all other UST owners. I. OWNERSHIP OF USTs II. LOCATION OF USTs Owner Name (Corporation, Individual, Public Agency, Or Other Entity)If required by implementing agency, give the geographic location of USTs either in decimal degrees, or degrees, minutes, and seconds. Example: Latitude: 36.123480 (or 36q 7' 24.4"), Longitude: -106.549876 (or -106q 32' 59.6") Latitude ________________ Longitude ________________ Street Address County Facility Name Or Company Site Identifier, As Applicable If address is the same as in Section I, check the box and proceed to section III. If address is different, enter address below: Street Address County City State Zip Code Phone Number (Include Area Code) City State Zip Code Utah Department of Environmental Quality, Division of Environmental Response and Remediation 195 North 1950 West,Salt Lake City,Utah 84116 ✔ 4 Walmart, Inc. 40.348499 -111.731817 Walmart Fueling Station #52702101 SE Simple Savings Drive Benton Bentonville 479.258.2364 Lindon AR UT 72716 84042 629 N. State Street Utah EPA Form 7530-1 (Rev. 6-2015)Electronic and paper versions acceptable. Page 2 of 6 Previous editions may be used while supplies last. United States Environmental Protection Agency Washington, DC 20460 Approval expires xx/xx/xx OMB No.2050-0068 Notification For Underground Storage Tanks III. TYPE OF OWNER IV. INDIAN COUNTRY Federal Government State Government Commercial Tribal Government Local Government Private USTs are located on land within an Indian reservation or on trust lands outside reservation boundaries Federally recognized tribe where USTs are located: V. TYPE OF FACILITY Auto Dealership Federal – Military Residential Commercial Airport Or Airline Gas Station Trucking Or Transport Contractor Industrial Utilities Farm Petroleum Distributor Other (Explain) ____________________ Federal – Non-military Railroad VI. CONTACT PERSON IN CHARGE OF TANKS Name:Job Title:Address:Phone Number (Include Area Code): VII. FINANCIAL RESPONSIBILITY I have met the financial responsibility requirements (in accordance with 40 CFR part 280 Subpart H) by using the following mechanisms: (check all that apply) Bond Rating Test Local Government Financial Test Surety Bond Commercial Insurance Risk Retention Group Trust Fund Guarantee Self-insurance (Financial Test) Other Method (describe here) Letter Of Credit State Fund ___________________________ I do not have to meet financial responsibility requirements because 40 CFR part 280 Subpart H is not applicable to me (e.g., if you are a state or federal owner). VIII. CERTIFICATION (Read and sign after completing ALL SECTIONS of this notification form) I certify under penalty of law that I have personally examined and am familiar with the information submitted in Sections I through XI of this notification form and all attached documents, and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true, accurate, and complete. Name and official title of owner or owner’s authorized representative (Print) Signature Date Signed Paperwork Reduction Act Notice The public reporting and recordkeeping burden for this collection of information is estimated to average 30 minutes per response. Responses to this collection of information are mandatory (40 CFR 280.22). An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB control number. This collection of information is approved by OMB under the Paperwork Reduction Act, 44 U.S.C. 3501 et seq. (OMB Control No. 2050- 0068). Send comments on the Agency's need for this information, the accuracy of the provided burden estimates, and any suggested methods for minimizing respondent burden, including through the use of automated collection techniques to the Director, Collection Strategies Division, U.S. Environmental Protection Agency (2822T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460. Include the OMB control number in any correspondence. Do not send the completed form to this address. ✔ ✔ Sara Gallien Fuel Compliance Manager 2101 SE Simple Savings Drive, Bentonville, Arkansas, 72716 479.258.2364 ✔ ✔ William Bailor - APTIM Environmental & Infrastructure, LLC as an agent for Walmart Inc.3/20/2024 EPA Form 7530-1 (Rev. 6-2015)Electronic and paper versions acceptable. Page 3 of 6 Previous editions may be used while supplies last. United States Environmental Protection Agency Washington, DC 20460 Approval expires xx/xx/xx OMB No.2050-0068 Notification For Underground Storage Tanks IX. DESCRIPTION OF UNDERGROUND STORAGE TANKS (Complete for all tanks and piping at this location) Tank Identification Number Tank No.Tank No. Tank No. Tank No. Tank No. 1. Status Of Tank (check only one) Currently In Use Temporarily Closed Permanently Closed 2. Date Of Installation (month/year) 3. Estimated Total Capacity (gallons) 4. Tank Attributes (check all that apply) Asphalt Coated Or Bare Steel Cathodically Protected Steel (impressed current) Cathodically Protected Steel (sacrificial anodes) Coated and Cathodically Protected Steel (impressed current) Coated and Cathodically Protected Steel (sacrificial anodes) Composite (steel clad with noncorrodible material) Concrete Fiberglass Reinforced Plastic Noncorrodible Tank Jacket Lined Interior Excavation Liner Double Walled Manifolded Compartmentalized Field-constructed Double Walled Unknown Other, Specify Here ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ Check Box If Tank Has Ever Been Repaired 5. Overfill Protection Installed (check all that apply) Automatic Shutoff Flow Restrictor High-level Alarm Other, Specify Here ___________ ___________ ___________ ___________ ___________ 6. Spill Prevention Installed Double Walled T1 ✔✔✔✔ 11/09/2023 11/09/2023 11/09/2023 11/09/2023 20,000 12,000 8,000 10,000 ✔✔✔✔ ✔✔✔✔ ✔✔ ✔✔✔✔ ✔✔✔✔ Flapper Valve Flapper Valve Flapper Valve Flapper Valve ✔✔✔✔ ✔✔✔✔ EPA Form 7530-1 (Rev. 6-2015)Electronic and paper versions acceptable. Page 4 of 6 Previous editions may be used while supplies last. United States Environmental Protection Agency Washington, DC 20460 Approval expires xx/xx/xx OMB No.2050-0068 Notification For Underground Storage Tanks Tank Identification Number Tank No.Tank No. Tank No. Tank No. Tank No. 7. Piping Attributes (check all that apply) Bare Steel Galvanized Steel Fiberglass Reinforced Plastic Flexible Plastic Copper Cathodically Protected (impressed current) Cathodically Protected (sacrificial anodes) Double Walled Secondary Containment Airport Hydrant Piping Unknown Other, Specify Here ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ 8. Piping Delivery Type (check all that apply) Safe Suction (no valve at tank) U.S. Suction (valve at tank) Pressure Gravity Feed 9. Substance Currently Stored (or last stored in the case of closed tanks) (check all that apply) *DVROLQHFRQWDLQLQJHWKDQRO Diesel Biodiesel Kerosene Heating Oil Used Oil *DVROLQH&RQWDLQLQJ!(thanol (specify amount of ethanol) ___________ ___________ ___________ ___________ ___________ 'LHVHO&RQWDLQLQJ!%iodiesel (specify amount of biodiesel) ___________ ___________ ___________ ___________ ___________ Other, specify here ___________ ___________ ___________ ___________ ___________ Hazardous Substance CERCLA Name Or CAS Number ___________ ___________ ___________ ___________ ___________ Mixture Of Substances Please Specify Substances Here ___________ ___________ ___________ ___________ ___________ ✔✔✔✔ ✔✔✔✔ ✔✔✔✔ ✔✔✔ ✔ EPA Form 7530-1 (Rev. 6-2015)Electronic and paper versions acceptable. Page 5 of 6 Previous editions may be used while supplies last. United States Environmental Protection Agency Washington, DC 20460 Approval expires xx/xx/xx OMB No.2050-0068 Notification For Underground Storage Tanks Tank Identification Number Tank No.Tank No. Tank No. Tank No. Tank No. 10. Release Detection (check all that apply) TANK PIPE TANK PIPE TANK PIPE TANK PIPE TANK PIPE Manual Tank Gauging Tank Tightness Testing Inventory Control Automatic Tank Gauging Vapor Monitoring Groundwater Monitoring Interstitial Monitoring (required for new or replaced tanks or piping) Statistical Inventory Reconciliation Automatic Line Leak Detectors Line Tightness Testing No Release Detection Required (such as some types of suction piping) Other Method Allowed By Implementing Agency Other, Specify Here ___________ ___________ ___________ ___________ ___________ X. CLOSURE OR CHANGE IN SERVICE 1. Closure Or Change In Service Estimated Date The UST Was Last Used For Storing Regulated Substances (month/day/year) ___________ ___________ ___________ ___________ ___________ Check Box If This Is A Change In Service (i.e., Change of storage to a non- regulated substance) 2. Tank Closure Estimated Date Tank Closed (month/day/year)___________ ___________ ___________ ___________ ___________ (check all that apply below) Tank Removed From Ground Tank Closed In Ground Tank Filled With Inert Material Describe The Inert Fill Material Here ___________ ___________ ___________ ___________ ___________ 3. Site Assessment Check Box If The Site Assessment Was Completed Check Box If Evidence Of A Release Was Detected Other, Specify Here ___________ ___________ ___________ ___________ ___________ ✔✔✔✔ ✔✔✔✔ ✔✔✔✔ ✔✔✔✔ ✔✔✔✔ T1 T2 T3 T4 DD4 TYP OF 2 2 FST1 43 FL073FL058c FUELING POSITION NUMBER TYP 65 FL044 TYP OF 8 FL058cFL073 1615 FL058eFL074 FST4 6 FL058eFL074 FL073FL058c FL058cFL073 87 1211 1413 SERVICE BUILDING FL060 FL061 TYP 21 FL074FL058a 109 SIDE "B" TYP SIDE "A" TYP FST4 1 TYP OF 4 TANK 1 UNLEADED 20,000 GALLONS VERIFY DURING PIPING INSPECTION THAT ALL TOPS OF MANHOLES ARE SET AT CORRECT GRADE ELEVATION TANK 3 SUPER UNLEADED 8,000 GALLONS PRODUCT FILL TO VENT RISER REF CIVIL DWGS FOR LOCATION TANK INTERSTITIAL SPACE RISER DIESEL VENT CONNECTION FL079 TYP REF 7 - FST3 TYP REF 6 - FST5 REF 3 - FST3 REF 3 - FST5 REF 1 - FST3TANK PROBE REF 7 - FST5 REF 5 - FST5 3 FST21 FST2 OBSERVATION WELL REF 2 - FST5 TANK INTERSTITIAL SPACE RISER TANK 2 UNLEADED 12,000 GALLONS 11.105 11.106 REF 2 - FST3 2 FST2 DIESEL PRODUCT FILL TANK 4 DIESEL 10,000 GALLONS EQUALIZATION PIPING REF 9 - FST3 VAPOR RECOVERY CONNECTION TYP REF 4 - FST5 REF 1 - FST5 REF 1 - FST5 11.106 PRODUCT PIPING TO SLOPE A MINIMUM OF 1/8" PER FOOT BETWEEN TANKS AND FIRST DISPENSER 11.106 11.106 FL074FL058a TYP OF 2FST4 6 1/8" = 1'-0" PIPING PLAN-3T1 1 N 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-130-24 March 28, 2024 Sara Gallien Walmart, Inc. 2101 Southeast Simple Savings Drive Bentonville, Arkansas 72716 Re: Notice of Approval to Remove Delivery Prohibition Tag Walmart Supercenter Fueling Station #5270 Located at 585 North State Street, Lindon, Utah Facility Identification No. 1000995 Dear Ms. Gallien: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to issue the attached certificate of compliance for the 20,000-gallon regular, 12,000-gallon regular, 8,000-gallon premium, and 10,000-gallon diesel tanks at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(6). Please remove and discard any tags that were attached to the fill for these tanks during installation. If you have additional questions, please contact the DERR project manager, identified on the red tag, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/LP/ss Enclosure: Certificate of Compliance cc: Eric Edwards, Executive Director, Utah County Health Department UST Red Tag Removal Letter – CoC Issuance Sign-Off Sheet ERRU#____________ Author Subject File Name on Google Drive Enclosures Attached CoC Attached Tank Data Sheet(internal use only – do not mail) Payment of Fees Confirmed? Priority CC’s Special Instructions Draft Approval Process Project Manager Section Manager Final Approval Process Section Secretary Author Branch Secretary Administrative Secretary Section Secretary Scan # Certified Mail Enclosures Included CC’s Mailed Mailed By LP LP CoC Tank Data Sheet Rush 03/26/2024 Yes Red Tag Removal Yes 1000995 Red Tag Removal Walmart Lindon Laura Perdue 03/2ц/2024 03/2ц/2024 SS 130-24 03/2ч/2024 LP LP 03/2ч/2024 SS 03/2ч/2024 03/2ч/2024 2024 UST CERTIFICATE OF COMPLIANCE ISSUED TO:LOCATION OF TANKS: SARA GALLIEN WALMART SUPERCENTER FUELING STATION #5270 WALMART INC.585 NORTH STATE STREET 2101 SE SIMPLE SAVINGS DR LINDON UT 84042 BENTONVILLE, AR 72716 Facility ID: 1000995 Tank #Capacity Substance Desc Compliance Financial Assurance Mechanism 1 20000 Gasoline Yes PST Fund 2a 12000 Gasoline Yes PST Fund 2b 8000 Gasoline Yes PST Fund 3 10000 Diesel Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :WALMART #WM5270 Name :TANKNOLOGY INC. Address :629 N STATE ST LINDON, UT 84042 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :-Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :16 Products per Nozzle :3 Tanks Manifolded ?Yes Drop-Out tank present?NO Total # of Tanks Tested :3 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) 1 RUL 19782 14929 4853 2 RUL 2 11904 7659 4245 3 PREMIUM 7901 4960 2941 14:49 2.00 2.00 1.99 1.99 1.98 1.98 1.92 Pass Total 39587 27548 12039 All 14:49 2.00 2.00 1.99 1.99 1.98 1.98 1.92 Pass Comments: Tester :David Mathie Test Date :3/14/2024 Signature :Work Order :2364469 WO: 2364469 PVVC tested ==>GAS Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>Husky Model Number ==>5885 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 9 0.0191 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.51 Pass Neg Leak Rate (CFH)0.21 18 0.0382 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.42 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0191 Total -ve LR: 0.0382 Test Date 3/14/2024 Technician Name David Mathie WO #2364469 Facility Name / Loc #WALMART #WM5270 WM5270 Street 629 N STATE ST City, St, Zip LINDON, UT 84042 Pressure Vacuum Vent Cap Test Form TP-201.1E ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 3/14/2024 UST Facility Person Conducting Test Facility Name WALMART #WM5270 Facility ID # WM5270 Tester's Name DMATHIE Physical Address 629 N STATE ST Company Tanknology Inc. City LINDON County UTAH State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner SAM'S CLUB Tester's Signature Date 3/14/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:1 RUL - 1 Y Y Y Y N Pass STP:2 RUL 2 - 1 Y Y Y Y N Pass STP:3 PREMIUM - 1 Y Y Y Y N Pass STP:4 Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2364469 PST Owner Information Facility ID# PST Facility Information Owner Name: Facility Name: Address: Address: City: State: Zip: City: State: UT Zip: Contact: Phone: Contact: Phone: DESCRIPTION OF PETROLEUM STORAGE TANKS Tank # UST or AST Date Installed Capacity Substance Stored TANK/LINE TIGHTNESS TEST Indicate Pass or Fail for each tank and product line tested. Include a copy of the test. Tank # Tank Test Line Test TYPE OF FACILITY Marketing facility, or non-marketer with facility average monthly throughput greater than 10,000 gallons. Non-marketer with facility average monthly throughput less than 10,000 gallons. COMPLIANCE WITH PST REGULATIONS All Petroleum Storage Tanks (PSTs) at this facility have been registered. Registration fees and Petroleum Storage Tank Fund Fees have been paid. Are your PSTs currently in compliance with all Federal, State, and Local PST regulations, including applicable Fire Code? Yes No If "No" describe items of non-compliance: PREVIOUS POLLUTION INCIDENTS Complete the Previous Pollution Incidents form to indicate whether a pollution incident has occurred at the facility. FINANCIAL RESPONSIBILITY MECHANISM DECLARATION (check one only) * Non-regulated PSTs at the facility may be required to participate in the Environmental Assurance Program. I choose another Financial Responsibility mechanism for the PSTs at this facility. •Indicate the financial responsibility mechanism to be used: •(For self-insurance or guarantee) Indicate your company’s fiscal year end date: •(For Insurance) Indicate the date the policy is renewed each year: The Certificate of Compliance cannot be issued until all documents have been submitted and the mechanism has been approved. If the mechanism has already been approved, submit documentation of coverage for the new tanks. I certify under penalty of law that the above representations made by me are true and correct. CofCapp 1022 Utah Petroleum Storage Tank Program Application for Certificate of Compliance I choose to participate in the Environmental Assurance Program (PST Fund) *. •Indicate the financial responsibility mechanism to be used for cleanup costs not covered by the Fund. •Indicate the number of non-regulated petroleum storage tanks at the facility. Owner/operator Signature Date Signed 1000995 T1 T2 T3 T4 N/A N/A UST UST UST UST 11/09/2023 11/09/2023 11/09/2023 11/09/2023 20,000 12,000 8,000 10,000 Reg. Unleaded Reg. Unleaded Super Unleaded Diesel T1 T2 T3 T4 N/A N/A PASS PASS PASS PASS PASS PASS PASS PASS 4 4 4 4 4 Insurance 3/25/2024 Walmart Inc. 2101 SE Simple Savings Drive Bentonville AR 72716 Sara Gallien 479.258.2364 Walmart Fueling Station #5270 629 North State Street Lindon 84042 Anderson Alves 801.785.7863 4 0