Loading...
HomeMy WebLinkAboutDAQ-2025-0025071 DAQC-470-25 Site ID 10355 (B5) MEMORANDUM TO: FILE – PACIFICORP – Gadsby Power Plant THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Rob Leishman, Environmental Scientist DATE: May 15, 2025 SUBJECT: Gadsby Power Plant (Gadsby), Major, SIP, Salt Lake County, FRS # UT00000049003500068 INSPECTION TYPE: State Electronic Data Report (SEDR) Review REVIEW DATE: May 15, 2025 SOURCE LOCATION: Salt Lake City/Salt Lake County SOURCE CONTACT: Bill Kennick – 801-220-7702 Leah Tiberius – 801-220-7708 APPLICABLE REGULATIONS: Title V Operating Permit Permit Number: 3500068006 Date of Permit: January 30, 2024 Date of Last Revision: January 30, 2024 SOURCE INSPECTION EVALUATION: With the exception of sources that only monitor for opacity, quarterly report memoranda will only address the findings of the quarterly report. Approval Order and Title V permit conditions addressing continuous emission monitoring requirements will be addressed in the relative accuracy performance specification test review memorandum. SYSTEM EVALUATION: First Quarter 2025 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation 1 640 NOx 98% 01/23/25 08/26/24 1 NOx 0.00 179 lb/hr - 3 hour rolling avg. 1 640 CO2 98% 01/23/25 1 NOx 0.00 336 ppmdv, 3% O2 dry - 3 hour rolling avg. 1 8 2 2 First Quarter 2025 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation 2 870 NOx 100% 01/21/25 08/26/24 2 NOx 0.00 204 lb/hr - 3 hour rolling avg. 2 870 CO2 100% 01/21/25 2 NOx 0.00 336 ppmdv, 3% O2 dry - 3 hour rolling avg. 3 984 NOx 100% 01/21/25 08/27/24 3 NOx 0.00 142 lb/hr, Nov. 1-Feb. 28(29) - 3 hour rolling avg. 3 984 CO2 100% 01/21/25 3 NOx 0.00 203 lb/hr, Mar. 1-Oct. 31 - 3 hour rolling avg. 4 27 NOx 91% 01/22/25 08/28/24 3 NOx 0.00 168 ppmdv, 3% O2 dry - 3 hour rolling avg. 4 27 CO 81% 01/22/25 08/28/24 4 NOx 0.00 5 ppmdv, 15% O2 dry - 30 day rolling average 4 27 O2 91% 01/22/25 08/28/24 5 NOx 0.00 5 ppmdv, 15% O2 dry - 30 day rolling average 5 24 NOx 93% 01/23/25 08/28/24 6 NOx 0.00 5 ppmdv, 15% O2 dry - 30 day rolling average 5 24 CO 93% 01/23/25 08/28/24 4 CO 0.00 10 ppmdv, 15% O2 dry - 8-hour block average 5 24 O2 93% 01/23/25 08/28/24 5 CO 0.00 10 ppmdv, 15% O2 dry - 8-hour block average 6 24 NOx 93% 01/24/25 08/29/24 6 CO 0.00 10 ppmdv, 15% O2 dry - 8-hour block average 6 24 CO 88% 01/24/25 08/29/24 4 NOx 0.00 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 6 24 O2 93% 01/24/25 08/29/24 5 NOx 0.00 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 6 NOx 0.00 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 3 First Quarter 2025 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation 4 NOx 0.00 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 5 NOx 0.00 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 6 NOx 0.00 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 4 CO 0.00 26.9 lb/hour,15% O2 dry - 8-hour block average for units 4, 5, 6 5 CO 0.00 26.9 lb/hour,15% O2 dry - 8-hour block average for units 4, 5, 6 6 CO 0.00 26.9 lb/hour,15% O2 dry - 8-hour block average for units 4, 5, 6 4 NOx 0.00 116 ppmdv, 15% O2 dry - 4 hour rolling average 5 NOx 0.00 116 ppmdv, 15% O2 dry - 4 hour rolling average 6 NOx 0.00 116 ppmdv, 15% O2 dry - 4 hour rolling average 4 Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit 1 NOx 0 0 0 0 0 179 lb/hr - 3 hour rolling avg. 1 NOx 0 0 0 0 0 336 ppmdv, 3% O2 dry - 3 hour rolling avg. 2 NOx 0 0 0 0 0 204 lb/hr - 3 hour rolling avg. 2 NOx 0 0 0 0 0 336 ppmdv, 3% O2 dry - 3 hour rolling avg. 3 NOx 0 0 0 0 0 142 lb/hr, Nov. 1-Feb. 28(29) - 3 hour rolling avg. 3 NOx 0 0 0 0 0 203 lb/hr, Mar. 1-Oct. 31 - 3 hour rolling avg. 3 NOx 0 0 0 0 0 168 ppmdv, 3% O2 dry - 3 hour rolling avg. 4 NOx 0 0 0 0 0 5 ppmdv, 15% O2 dry - 30 day rolling average 5 NOx 0 0 0 0 0 5 ppmdv, 15% O2 dry - 30 day rolling average 6 NOx 0 0 0 0 0 5 ppmdv, 15% O2 dry - 30 day rolling average 4 CO 0 0 0 0 0 10 ppmdv, 15% O2 dry - 8-hour block average 5 CO 0 0 0 0 0 10 ppmdv, 15% O2 dry - 8-hour block average 6 CO 0 0 0 0 0 10 ppmdv, 15% O2 dry - 8-hour block average 4 NOx 0 0 0 0 0 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 5 NOx 0 0 0 0 0 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 6 NOx 0 0 0 0 0 22.2 lb/hour,15% O2 dry - 30 day rolling average for units 4, 5, 6 4 NOx 0 0 0 0 0 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 5 NOx 0 0 0 0 0 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 6 NOx 0 0 0 0 0 600 lb/day,15% O2 dry - 24- hour block average for units 4, 5, 6 4 CO 0 0 0 0 0 26.9 lb/hour,15% O2 dry - 8- hour block average for units 4, 5, 6 5 CO 0 0 0 0 0 26.9 lb/hour,15% O2 dry - 8- hour block average for units 4, 5, 6 5 Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit 6 CO 0 0 0 0 0 26.9 lb/hour,15% O2 dry - 8- hour block average for units 4, 5, 6 4 NOx 0 0 0 0 0 116 ppmdv, 15% O2 dry - 4 hour rolling average 5 NOx 0 0 0 0 0 116 ppmdv, 15% O2 dry - 4 hour rolling average 6 NOx 0 0 0 0 0 116 ppmdv, 15% O2 dry - 4 hour rolling average CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes 1 NOx 0 0 16 0 0 1 CO2 0 0 16 0 0 2 NOx 0 0 2 0 0 2 CO2 0 0 2 0 0 3 NOx 0 0 0 0 0 3 CO2 0 0 0 0 0 4 NOx 0 1 1 0 0 4 CO 0 5 1 0 0 4 O2 0 1 1 0 0 5 NOx 0 0 2 0 0 5 CO 0 0 2 0 0 5 O2 0 0 2 0 0 6 NOx 0 0 2 0 0 6 CO 0 0 3 0 0 6 O2 0 0 2 0 0 Pollutant Concentration Exceeded Span of CEM Monitor Outage During Point Source Operation Alternate Sampling CEM Modifications 0 Hours 57 Hours 0 Hours 0 Events 6 SOURCE INSPECTION SUMMARY EVALUATION: Gadsby maintains its CEMS as required in R307-170 and 40 CFR 60.13. CURRENT RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related problems that do not warrant issuing a violation. Gadsby was in compliance during this reporting period. No enforcement actions are recommended at this time. The NSPS monitoring system meets the performance standards of 40 CFR 60, Appendix B Performance Specifications. Gadsby’s acid rain monitoring system meets the performance standards of 40 CFR 75 Acid Rain Performance Specifications. HPV: No RECOMMENDATION FOR NEXT INSPECTION: Check DAS for daily zero and span drift. Check the QC program to ensure that monitor drift is being tracked and that the source can identify excessive drift. ATTACHMENTS: Excel spreadsheet review Yr,*sl*flsg.n"r Gadsby Plant 1359 West North Temple (Rear) Salt Lake City, UT 841 16 Re: April28,2025 Bryce Bird, Director Utah Department of Environmental Quality Division of Air Quality P.O. Box 144820 Salt Lake City, UT 84114-4820 USEPA Acid Rain Prooram's 1tt Quarter. 2025 Report - Gadsbv Plant Dear Mr. Bird: The quarterly reports for the 1st quarter 2025 for the Gadsby Plant, ORIS Code 3648, boiler/stack lD's 1 , 2, 3, 4,5, and 6 have been submitted electronically to, and accepted by, the Environmental Protection Agency. The submittals are summarized in the following table: Boiler lD Submission Type Date of Submittal Receipt lD 1 Emissions 0412312025 1 759209 1 Qualitv Assurance / Certification 0412312025 1 759208 2 Emissions 0412312025 1759225 2 Qualitv Assurance / Certification o4123t2025 1759224 3 Emissions 0412312025 1759236 3 Qualitv Assurance / Certification 0412312025 1759235 4 Emissions 0412312025 1759246 4 Qualitv Assurance / Certification 04t23t2025 1759245 5 Emissions 0412312025 1759253 5 Quality Assurance / Certification 0412312025 1759252 6 Emissions 04123t202s 1759258 6 Quality Assurance / Certification 0412312025 1759257 Electronic copies of these reports are included with this mailing for the Utah Division of Air Quality. I certify that all data submitted in this report were recorded in accordance with the applicable requirements of 40 CFR Part 75, and that all emission and quality control data are reported using component lD codes, system lD codes, and formula lD codes which represent current operating conditions. I am authorized to make this submission on behalf of the owners and operators of the affected source or affected units for which the submission is made. I certify under penalty of law that I have personally examined, and am familiar with, the statements and information submitted in this document and all its attachments. Based on my inquiry of those individuals with primary responsibility for obtaining the information, I certify that the statements and information are to the best of my knowledge and belief true, ENVIRONMENTAL OUAUTY APR 2 I ?f;?r: accurate, and complete. I am aware that there are significant penalties for submitting false statements and information, or omitting statements and information, including the possibili$ of fine or imprisonment. Should you have any questions regarding this information, please contact Bill Kennick, Gadsby Plant Manager (801) 220-7702 or Brett Shakespear, PacifiCorp Environmental Manager (801) 2204581 . Sincerely, eqk*A BillKennick Plant Manager Gadsby Plant Enclosure: Electronic Data Reports cc: Director - USEPA Region Vlllw/o enclosure Brett Shakespear - 210 NTO w/o enclosure Leah Tiberius - Gadsby Plant Menclosure Pacificorp Gadsby EER1Q2025 Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No 1 Type Code 100 (Company Information)Type Code Company Manager Company Name AIRS # Phone Number Environmental Contact 1 100 Bill Kennick 03500068 801-227708 Leah Tiberius Dickson 1 100 0 0 0 0 1 Type Code 110 (Point Source Identification)Type Code Point Source Quarter 1 - 4 Year Point Source Operating Hrs. in Quarter 1 110 1 2025 640.92 1 110 1 2025 870.52 1 110 1 2025 984.63 1 110 1 2025 27.22 1 110 1 2025 24.36 1 110 1 2025 24.74 1 110 0 0 0 1 Type Code 200 (Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor Location 1 200 CO2 Thermo 410iQHL-ABN 12305124129 0 20 8/14/2023 Shelter 1 200 NOx Thermo 42iQLS-ACBNN 12309525996 0 200 8/14/2023 Shelter 1 200 CO2 Thermo 410iQHL-ABN 12305124128 0 20 8/14/2023 Shelter 1 200 NOx Thermo 42iQLS-ACBNN 12309525997 0 200 8/14/2023 Shelter 1 200 CO2 Thermo 410iQHL-ABN 12305124127 0 20 8/14/2023 Shelter 1 200 NOx Thermo 42iQLS-ACBNN 12309525998 50 200 8/14/2023 Shelter 1 200 CO Thermo 48iQ-ABC 12305124124 20 200 8/15/2023 Shelter 1 200 NOx Thermo 42iQLS-ACBNN 12318428624 10 200 8/15/2023 Shelter 1 200 O2 Thermo 48iQ-ABC 12305124124 0 25 8/15/2023 Shelter 1 200 CO Thermo 48iQ-ABC 12305124125 20 200 8/17/2023 Shelter 1 200 NOx Thermo 42iQLS 12305124117 10 200 8/17/2023 Shelter 1 200 O2 Thermo 48iQ-ABC 12305124125 0 25 8/17/2023 Shelter 1 200 CO Thermo 48iQ-ABC 12305124126 20 200 8/16/2023 Shelter 1 200 NOx Thermo 42iQLS-ACBNN 12309525999 10 200 8/16/2023 Shelter 1 200 O2 Thermo 48iQ-ABC 12305124126 0 25 8/16/2023 Shelter 1 200 0 0 0 0 0 0 1/0/1900 0 1 Type Code310 (Excess Emissions) SUMMARY REPORT Type Code Channel Total Hours of Excess Emissions Excess Emissions - % of Total Operating Hours RC 701 Hours - start up/Shutdown RC 702 Hours- Control Equipment Problems RC 703 Hours - Process Problems RC 704, 706, 707 Hours -Other Known Causes RC 705 Hours - Unknown Causes Emission Limitation Emission Limitation Units Emission Limitation Averaging Period 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 179 lb/hr 3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 336 ppmdv, 3% O2 dry3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 204 lb/hr 3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 336 ppmdv, 3% O2 dry3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 142 lb/hr, Nov. 1-Feb. 28(29)3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 203 lb/hr, Mar. 1-Oct. 31 3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 168 ppmdv, 3% O2 dry3 hour rolling avg. 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 5 ppmdv, 15% O2 dry30 day rolling average 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 5 ppmdv, 15% O2 dry30 day rolling average 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 5 ppmdv, 15% O2 dry30 day rolling average 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 10 ppmdv, 15% O2 dry8 hour block average 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 10 ppmdv, 15% O2 dry8 hour block average 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 10 ppmdv, 15% O2 dry8 hour block average 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 22.2 lb/hour,15% O2 dry30 day rolling average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 22.2 lb/hour,15% O2 dry30 day rolling average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 22.2 lb/hour,15% O2 dry30 day rolling average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 600 lb/day,15% O2 dry24 hour block average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 600 lb/day,15% O2 dry24 hour block average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 600 lb/day,15% O2 dry24 hour block average for units 4, 5, 6 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 26.9 lb/hour,15% O2 dry8 hour block average for units 4, 5, 6 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 26.9 lb/hour,15% O2 dry8 hour block average for units 4, 5, 6 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 26.9 lb/hour,15% O2 dry8 hour block average for units 4, 5, 6 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 116 ppmdv, 15% O2 dry4 hour rolling average 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 116 ppmdv, 15% O2 dry4 hour rolling average 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 116 ppmdv, 15% O2 dry4 hour rolling average 1 310 0 0 0 0 0 0 0 0 0 6 4 5 6 4 5 6 4 5 6 4 5 6 0 5 6 6 6 0 PacifiCorp Gadsby Plant 0 1 1 2 2 3 3 4 4 4 5 5 3 3 4 1 2 3 4 5 6 0 2 2 3 4 5 Point Source 5 6 1 1 Pacificorp Gadsby EER1Q2025 1 Type Code 300 (CMS Performance Summary) Type Code Channel Point Source Operating Hours Downtime - % of Total Operating Hours Total CMS Downtime RC 721 Hours - Monitor Malfunction RC 722 Hours - Non-monitor Malfunction RC 723 Hours - QA Calibrations RC 724 Hours - Other Known Causes RC 725 Hours - Unknown Causes 1 TRUE 300 NOx 640.92 2.43% 15.583 0 0 15.533 0.05 0 1 TRUE 300 CO2 640.92 2.43% 15.583 0 0 15.533 0.05 0 1 TRUE 300 NOx 870.52 0.24% 2.117 0 0 2.117 0 0 1 TRUE 300 CO2 870.52 0.24% 2.117 0 0 2.117 0 0 1 TRUE 300 NOx 984.63 0.00% 0 0 0 0 0 0 1 TRUE 300 CO2 984.63 0.00% 0 0 0 0 0 0 1 TRUE 300 NOx 27.22 8.51% 2.317 0 1.267 1.05 0 0 1 TRUE 300 CO 27.22 19.47% 5.3 0 4.633 0.667 0 0 1 TRUE 300 O2 27.22 8.51% 2.317 0 1.267 1.05 0 0 1 TRUE 300 NOx 24.36 6.57% 1.6 0 0 1.6 0 0 1 TRUE 300 CO 24.36 6.57% 1.6 0 0 1.6 0 0 1 TRUE 300 O2 24.36 6.57% 1.6 0 0 1.6 0 0 1 TRUE 300 NOx 24.74 7.14% 1.766 0 0 1.733 0.033 0 1 TRUE 300 CO 24.74 12.19% 3.016 0 0 2.983 0.033 0 1 TRUE 300 O2 24.74 7.14% 1.766 0 0 1.733 0.033 0 1 300 0 0 0 0 0 0 1 Type Code 250 (Performance Specification RATA Results) Type Code Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units of Measurement CEM Value Reference Method Value Relative accuracy Pass/ Fail 1 350 Days 250 NOx 08/26/24 09/11/23 11.5 #/MMBtu, CO2dil. 0.146 0.14 [d] = 0.006 pass 1 350 Days 250 NOx 08/26/24 09/11/23 11.5 ppmvd @ 3 O2 120.633 116.344 5.11% pass 1 346 Days 250 NOx 08/26/24 09/15/23 11.4 #/MMBtu, CO2dil. 0.144 0.148 [d] = 0.004 pass 1 346 Days 250 NOx 08/26/24 09/15/23 11.4 ppmvd @ 3 O2 119.333 115.967 4.56% pass 1 349 Days 250 NOx 08/27/24 09/13/23 11.5 #/MMBtu, CO2dil. 0.099 0.105 [d] = 0.006 pass 1 349 Days 250 NOx 08/27/24 09/13/23 11.5 ppmvd @ 3 O2 81.411 85.356 5.17% pass 1 349 Days 250 NOx 08/28/24 09/14/23 11.5 ppmvd @15O2 2.744 2.522 13.30% pass 1 349 Days 250 NOx 08/28/24 09/14/23 11.5 #/MMBtu, O2dil. 0.01 0.009 [d] = 0.001 pass 1 349 Days 250 O2 08/28/24 09/14/23 11.5 vd 16.078 16.256 1.49% pass 1 349 Days 250 CO 08/28/24 09/14/23 11.5 ppmvd @15O2 1.978 1.1 [d] + CC = 0.93Apass 1 348 Days 250 NOx 08/28/24 09/15/23 11.4 ppmvd @15O2 3.178 3.433 9.40% pass 1 348 Days 250 NOx 08/28/24 09/15/23 11.4 #/MMBtu, O2dil. 0.012 0.013 [d] = 0.001 pass 1 348 Days 250 O2 08/28/24 09/15/23 11.4 vd 16.222 16.211 0.35% pass 1 348 Days 250 CO 08/28/24 09/15/23 11.4 ppmvd @15O2 2.078 1.767 [d] + CC = 0.36Apass 1 350 Days 250 NOx 08/29/24 09/14/23 11.5 ppmvd @15O2 2.456 2.367 6.77% pass 1 350 Days 250 NOx 08/29/24 09/14/23 11.5 #/MMBtu, O2dil. 0.009 0.009 [d] = 0.000 pass 1 350 Days 250 O2 08/29/24 09/14/23 11.5 vd 16.278 16.411 1.39% pass 1 350 Days 250 CO 08/29/24 09/14/23 11.5 ppmvd @15O2 1.522 1.333 [d] + CC = 0.29Apass 1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0 1 Type Code 260 (CGA Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 260 CO 01/22/25 low DT0016399 08/16/25 P1 ppm 4.941 5 120.00% Pass Low 1 Valid Cal. Gas 260 CO 01/22/25 mid CC117990 09/11/25 P1 ppm 10.87 11.1 210.00% Pass Low 1 Valid Cal. Gas 260 CO 01/22/25 low DT0008297 08/06/27 P1 ppm 50.638 49.2 290.00% Pass High 1 Valid Cal. Gas 260 CO 01/22/25 mid DT0027748 12/01/30 P1 ppm 110.206 110.3 10.00% Pass High 1 Valid Cal. Gas 260 CO 01/23/25 low SGAL1089 06/04/29 P1 ppm 5.29 5.17 230.00% Pass Low 1 Valid Cal. Gas 260 CO 01/23/25 mid CC144297 08/16/25 P1 ppm 11.58 11.01 520.00% Pass Low 1 Valid Cal. Gas 260 CO 01/23/25 low CC3243 09/24/27 P1 ppm 52.287 49.5 560.00% Pass High 1 Valid Cal. Gas 260 CO 01/23/25 mid DT0038127 12/01/30 P1 ppm 111.981 110.4 140.00% Pass High 1 Valid Cal. Gas 260 CO 01/24/25 low CC104785 05/29/28 P1 ppm 5.018 4.99 60.00% Pass Low 1 Valid Cal. Gas 260 CO 01/24/25 mid CC16142 09/11/25 P1 ppm 11.061 11.07 10.00% Pass Low 1 Valid Cal. Gas 260 CO 01/24/25 low CC11331 09/24/27 P1 ppm 51.158 49.2 400.00% Pass High 1 Valid Cal. Gas 260 CO 01/24/25 mid DT0029072 12/01/30 P1 ppm 110.056 110.1 0.00% Pass High 1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 4 4 5 5 5 5 6 2 2 3 3 1 6 0 5 5 5 6 6 4 5 5 5 6 4 4 4 4 5 2 3 3 4 4 1 Point Source Point Source Point Source 6 6 6 0 4 4 6 1 2 6 6 0 1 Pacificorp Gadsby EER1Q2025 1 Type Code 270 (Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 270 CO2 01/23/25 low DT0045488 06/22/30 P1 % 5.1 5 200.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/23/25 mid DT0048948 11/25/32 P1 % 11 11 0.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/23/25 high EB0147361 10/07/30 P1 % 17.333 18 370.00% Pass 0 1 Valid Cal. Gas 270 NOx 01/23/25 low DT0045488 06/22/30 P1 ppm 51.067 50.1 190% Pass high 1 Valid Cal. Gas 270 NOx 01/23/25 mid DT0048948 11/25/32 P1 ppm 109.3 108.8 50% Pass high 1 Valid Cal. Gas 270 NOx 01/23/25 high EB0147361 10/07/30 P1 ppm 173.867 180 340% Pass high 1 Valid Cal. Gas 270 CO2 01/21/25 low DT0045488 06/22/30 P1 % 5.1 5 200.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/21/25 mid CC135043 12/07/31 P1 % 10.9 10.9 0.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/21/25 high EB0147361 10/07/30 P1 % 18.2 18 110.00% Pass 0 1 Valid Cal. Gas 270 NOx 01/21/25 low DT0045488 06/22/30 P1 ppm 50.033 50.1 10.00% Pass high 1 Valid Cal. Gas 270 NOx 01/21/25 mid CC135043 12/07/31 P1 ppm 108 108 0.00% Pass high 1 Valid Cal. Gas 270 NOx 01/21/25 high EB0147361 10/07/30 P1 ppm 174.3 180 320.00% Pass high 1 Valid Cal. Gas 270 CO2 01/21/25 low DT0045527 06/22/30 P1 % 5.1 5 200.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/21/25 mid CC120977 12/07/31 P1 % 11.033 11 30.00% Pass 0 1 Valid Cal. Gas 270 CO2 01/21/25 high CC328287 11/22/30 P1 % 17.6 18.2 330.00% Pass 0 1 Valid Cal. Gas 270 NOx 01/21/25 low DT0008500 02/11/25 P1 ppm 11.933 12.2 220% Pass Low 1 Valid Cal. Gas 270 NOx 01/21/25 mid CC17461 02/21/27 P1 ppm 26.933 26.9 10% Pass Low 1 Valid Cal. Gas 270 NOx 01/21/25 high DT0013934 04/14/25 P1 ppm 45.6 45.8 40% Pass Low 1 Valid Cal. Gas 270 NOx 01/21/25 low DT0045527 06/22/30 P1 ppm 50.333 50 70.00% Pass High 1 Valid Cal. Gas 270 NOx 01/21/25 mid CC120977 12/07/31 P1 ppm 109 108.5 50.00% Pass High 1 Valid Cal. Gas 270 NOx 01/21/25 high CC328287 11/22/30 P1 ppm 174.9 180.7 320.00% Pass High 1 Valid Cal. Gas 270 NOx 01/22/25 low DT0008297 08/06/27 P1 ppm 49 50.8 350.00% Pass High 1 Valid Cal. Gas 270 NOx 01/22/25 mid CC328418 08/13/29 P1 ppm 108.533 110.6 190.00% Pass High 1 Valid Cal. Gas 270 NOx 01/22/25 high DT0027748 12/01/30 P1 ppm 178.4 180 90.00% Pass High 1 Valid Cal. Gas 270 O2 01/22/25 low DT0016399 08/16/25 P1 % 6.233 6.3 110.00% Pass 0 1 Valid Cal. Gas 270 O2 01/22/25 mid CC117990 09/11/25 P1 % 13.5 13.5 0.00% Pass 0 1 Valid Cal. Gas 270 O2 01/22/25 high CC244369 11/09/31 P1 % 20.933 21 30.00% Pass 0 1 Valid Cal. Gas 270 NOx 01/23/25 low CC3243 09/24/27 P1 ppm 47.933 49.6 340.00% Pass High 1 Valid Cal. Gas 270 NOx 01/23/25 mid CC240996 06/09/28 P1 ppm 107.267 108.4 100.00% Pass High 1 Valid Cal. Gas 270 NOx 01/23/25 high DT0038127 12/01/30 P1 ppm 177.267 180 150.00% Pass High 1 Valid Cal. Gas 270 O2 01/23/25 low SGAL1089 06/04/29 P1 % 6.2 6.3 160.00% Pass 0 1 Valid Cal. Gas 270 O2 01/23/25 mid CC144297 08/16/25 P1 % 13.5 13.5 0.00% Pass 0 1 Valid Cal. Gas 270 O2 01/23/25 high DT0044634 09/16/32 P1 % 20.9 21.1 90.00% Pass 0 1 Valid Cal. Gas 270 NOx 01/24/25 low CC11331 09/24/27 P1 ppm 48.333 49.7 280.00% Pass High 1 Valid Cal. Gas 270 NOx 01/24/25 mid CC283263 11/21/30 P1 ppm 110.7 112.1 120.00% Pass High 1 Valid Cal. Gas 270 NOx 01/24/25 high DT0029072 12/01/30 P1 ppm 179.567 181 80.00% Pass High 1 Valid Cal. Gas 270 O2 1/24/25 low CC104785 5/29/28 P1 % 6 6 0 Pass 0 1 Valid Cal. Gas 270 O2 1/24/25 mid CC16142 9/11/25 P1 % 14 14 0 Pass 0 1 Valid Cal. Gas 270 O2 1/24/25 high CC28016 11/9/31 P1 % 21 21 0 Pass 0 1 270 0 1/0/00 0 0 1/0/00 0 0 0 0 0 0 0 1 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code Channel Start Date Start Time End Date End Time Hours 1 0 0 0 1/0/00 0:00 1/0/00 0:00 1 1 None Reported 1 0 TC 220 Hours 56.68 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00 1 56.68 TC 300 Hours 0.00 TRUE 2 0 0 3 3 3 1 2 2 2 2 1 1 1 1 1 3 3 2 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code 220 (Monitor Outage During Point Source Operation) Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) Type Code 240 (CEM Modifications) Type Code 530 (Excess Emissions During Emergency Conditions) Type Code 550 (Changes in Operation in Control Equipment When CEM Data Not Available) Type Code 500 (Boiler Operating Days w/o 18 Hours of Data) Type Code 450 (Data Excluded) Point Source Point Source Yes 3 3 3 3 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 6 None Reported None Reported None Reported None Reported None Reported None Reported Pacificorp Gadsby EER1Q2025 Relative Accuracy Overview Point Source Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units Measured CEM Value Reference Method Value Relative Accuracy Pass/ Fail 2025 1 NOx 08/26/24 09/11/23 11.5 #/MMBtu, CO2dil.0.146 0.14 [d] = 0.006 pass 1 NOx 08/26/24 09/11/23 11.5 ppmvd @ 3 O2 120.633 116.34 5.11% pass 2 NOx 08/26/24 09/15/23 11.4 #/MMBtu, CO2dil.0.144 0.15 [d] = 0.004 pass 2 NOx 08/26/24 09/15/23 11.4 ppmvd @ 3 O2 119.333 115.97 4.56% pass 3 NOx 08/27/24 09/13/23 11.5 #/MMBtu, CO2dil.0.099 0.11 [d] = 0.006 pass 3 NOx 08/27/24 09/13/23 11.5 ppmvd @ 3 O2 81.411 85.36 5.17% pass 4 NOx 08/28/24 09/14/23 11.5 ppmvd @15O2 2.744 2.52 13.30% pass 4 NOx 08/28/24 09/14/23 11.5 #/MMBtu, O2dil. 0.01 0.01 [d] = 0.001 pass 4 O2 08/28/24 09/14/23 11.5 vd 16.078 16.26 1.49% pass 4 CO 08/28/24 09/14/23 11.5 ppmvd @15O2 1.978 1.10 [d] + CC = 0.93A pass 5 NOx 08/28/24 09/15/23 11.4 ppmvd @15O2 3.178 3.43 9.40% pass 5 NOx 08/28/24 09/15/23 11.4 #/MMBtu, O2dil. 0.012 0.01 [d] = 0.001 pass 5 O2 08/28/24 09/15/23 11.4 vd 16.222 16.21 0.35% pass 5 CO 08/28/24 09/15/23 11.4 ppmvd @15O2 2.078 1.77 [d] + CC = 0.36A pass 6 NOx 08/29/24 09/14/23 11.5 ppmvd @15O2 2.456 2.37 6.77% pass 6 NOx 08/29/24 09/14/23 11.5 #/MMBtu, O2dil. 0.009 0.01 [d] = 0.000 pass 6 O2 08/29/24 09/14/23 11.5 vd 16.278 16.41 1.39% pass 6 CO 08/29/24 09/14/23 11.5 ppmvd @15O2 1.522 1.33 [d] + CC = 0.29A pass NSPS CGA First 2025 Audit Gas Ranges Audit Gas Ranges AP1 Low AP2 Low AP1 High AP2 High 4 CO 1/22/25 20 5 4 to 6 4 CO 1/22/25 20 11.1 10 to 12 4 CO 1/22/25 200 49.2 40 to 60 4 CO 1/22/25 200 110.3 100 to 120 5 CO 1/23/25 20 5.17 4 to 6 5 CO 1/23/25 20 11.01 10 to 12 5 CO 1/23/25 200 49.5 40 to 60 5 CO 1/23/25 200 110.4 100 to 120 6 CO 1/24/25 20 4.99 4 to 6 6 CO 1/24/25 20 11.07 10 to 12 6 CO 1/24/25 200 49.2 40 to 60 6 CO 1/24/25 200 110.1 100 to 120 Acid Rain Audit Linearity First 2025 Low Span Gas Ranges High Span Gas Ranges Low Mid High Low Mid High 1 CO2 1/23/25 20 5 4 to 6 1 CO2 1/23/25 20 11 10 to 12 1 CO2 1/23/25 20 18 16 to 20 1 NOx 1/23/25 200 50.1 40 to 60 1 NOx 1/23/25 200 108.8 100 to 120 1 NOx 1/23/25 200 180 160 to 200 2 CO2 1/21/25 20 5 4 to 6 2 CO2 1/21/25 20 10.9 10 to 12 2 CO2 1/21/25 20 18 16 to 20 2 NOx 1/21/25 200 50.1 40 to 60 2 NOx 1/21/25 200 108 100 to 120 2 NOx 1/21/25 200 180 160 to 200 3 CO2 1/21/25 20 5 4 to 6 3 CO2 1/21/25 20 11 10 to 12 3 CO2 1/21/25 20 18.2 16 to 20 3 NOx 1/21/25 50 12.2 10 to 15 3 NOx 1/21/25 50 26.9 25 to 30 3 NOx 1/21/25 50 45.8 40 to 50 3 NOx 1/21/25 200 50 40 to 60 3 NOx 1/21/25 200 108.5 100 to 120 3 NOx 1/21/25 200 180.7 160 to 200 4 NOx 1/22/25 200 50.8 40 to 60 4 NOx 1/22/25 200 110.6 100 to 120 4 NOx 1/22/25 200 180 160 to 200 4 O2 1/22/25 25 6.3 5 to 7.5 4 O2 1/22/25 25 13.5 12.5 to 15 4 O2 1/22/25 25 21 20 to 25 5 NOx 1/23/25 200 49.6 40 to 60 5 NOx 1/23/25 200 108.4 100 to 120 5 NOx 1/23/25 200 180 160 to 200 5 O2 1/23/25 25 6.3 5 to 7.5 5 O2 1/23/25 25 13.5 12.5 to 15 5 O2 1/23/25 25 21.1 20 to 25 6 NOx 1/24/25 200 49.7 40 to 60 6 NOx 1/24/25 200 112.1 100 to 120 6 NOx 1/24/25 200 181 160 to 200 6 O2 1/24/25 25 6.3 5 to 7.5 6 O2 1/24/25 25 13.5 12.5 to 15 6 O2 1/24/25 25 21.1 20 to 25 Audit Gas Used Point Source Channel Audit Date Low Span Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used High SpanAudit Gas Used Pacificorp Gadsby EER1Q2025 Monitoring Information TC 210, 230, & 240 Type Code 210(Pollutant ConcentraƟon Exceeded Span of CEM) - 500(All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 230(Manual Sample - Alternate Sampling During Monitor Outage) - 500(All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 240(CEM ModificaƟons) - 100 (All) * Count of Channel Column Labels Row Labels (blank) Grand Total (blank) (blank) Grand Total Pacificorp Gadsby EER1Q2025 Type Code 220 (Monitor Outage During Point Source Operation) - 600 (All) * Sum of Hours Column Labels Row Labels 724 723 722 Grand Total 1 CO2 Normal blowback cycle began just as the unit was taken off line or immediately following a calibration. No action necessary 0.05 0.05 After previous calibration expired when the unit was run again, a calibration was not performed in the 8 hour grace period after startup occurred. 7.85 7.85 No valid calibration in previous 26 hours. Unit did not stay online previously long enough to complete a calibration test. Operators were instructed to verify unit is on line before initiating a calibration. 7.68 7.68 NOx Normal blowback cycle began just as the unit was taken off line or immediately following a calibration. No action necessary 0.05 0.05 After previous calibration expired when the unit was run again, a calibration was not performed in the 8 hour grace period after startup occurred. 7.85 7.85 No valid calibration in previous 26 hours. Unit did not stay online previously long enough to complete a calibration test. Operators were instructed to verify unit is on line before initiating a calibration. 7.68 7.68 2 CO2 After previous calibration expired when the unit was run again, a calibration was not performed in the 8 hour grace period after startup occurred. 0.18 0.18 No valid calibration in previous 26 hours. Unit did not stay online previously long enough to complete a calibration test. Operators were instructed to verify unit is on line before initiating a calibration. 0.50 0.50 Manual or auto cal failure. Cal initiated again without any maintenance or after minor maintenance adjustments.0.52 0.52 System placed in maintenance mode to manually calibrate the analyzer. The system was then returned to service and an auto calibration was initiated. 0.85 0.85 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.0.07 0.07 NOx After previous calibration expired when the unit was run again, a calibration was not performed in the 8 hour grace period after startup occurred. 0.18 0.18 No valid calibration in previous 26 hours. Unit did not stay online previously long enough to complete a calibration test. Operators were instructed to verify unit is on line before initiating a calibration. 0.50 0.50 Manual or auto cal failure. Cal initiated again without any maintenance or after minor maintenance adjustments.0.52 0.52 System placed in maintenance mode to manually calibrate the analyzer. The system was then returned to service and an auto calibration was initiated. 0.85 0.85 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.0.07 0.07 4 NOx Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.0.67 0.67 The span gas regulator malfunctioned resulting in insufficient span gas flow to the analyzer during the daily calibration causing it to fail. The regulator was replaced and a second calibration drift test was performed. 4.63 4.63 CO Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.05 1.05 The span gas regulator malfunctioned resulting in insufficient span gas flow to the analyzer during the daily calibration causing it to fail. The regulator was replaced and a second calibration drift test was performed. 1.27 1.27 O2 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.05 1.05 The span gas regulator malfunctioned resulting in insufficient span gas flow to the analyzer during the daily calibration causing it to fail. The regulator was replaced and a second calibration drift test was performed. 1.27 1.27 Pacificorp Gadsby EER1Q2025 Sum of Hours Column Labels Row Labels 724 723 722 Grand Total 5 NOx Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.60 1.60 CO Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.60 1.60 O2 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.60 1.60 6 NOx Manual or auto cal failure. Cal initiated again without any maintenance or after minor maintenance adjustments.1.25 1.25 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.30 1.30 A Linearity/RATA Test run was performed on the analyzer, which failed and was aborted. Maintenance was performed on the analyzer and recalibrated. The analyzer was then returned to service. 0.03 0.03 Prep for RATA/Linearity testing or unit startup.0.43 0.43 CO Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.30 1.30 A Linearity/RATA Test run was performed on the analyzer, which failed and was aborted. Maintenance was performed on the analyzer and recalibrated. The analyzer was then returned to service. 0.03 0.03 Prep for RATA/Linearity testing or unit startup.0.43 0.43 O2 Not a valid hour during hour of calibration or prior to valid calibration. Or not enough valid minutes to make a valid hour.1.30 1.30 A Linearity/RATA Test run was performed on the analyzer, which failed and was aborted. Maintenance was performed on the analyzer and recalibrated. The analyzer was then returned to service. 0.03 0.03 Prep for RATA/Linearity testing or unit startup.0.43 0.43 Grand Total 0.20 49.32 7.17 56.68 Pacificorp Gadsby EER1Q2025 NOx * NOx Type Code 420 (NOx) - 6000 (All) NOx * NOx Count of Magnitude of Emissions Column Labels NOx Row Labels (blank)Grand Total NOx 1 NOx 0 NOx 2 NOx 0 NOx 3 NOx 0 NOx 4 NOx 0 NOx 5 NOx 0 NOx 6 NOx 0 NOx Grand Total CO * CO Type Code 440 (CO) - 6000 (All) CO * CO Count of Magnitude of Emissions Column Labels CO Row Labels (blank)Grand Total CO 4 CO 0 CO 5 CO 0 CO 6 CO 0 CO Grand Total O2 * O2 Type Code 470 (TRS as O2) - 6000 (All) O2 * O2 Count of Magnitude of Emissions Column Labels O2 Row Labels Grand Total O2 Grand Total Pacificorp Gadsby EER1Q2025 Type Code 500 Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of Data) After February 28, 2005 (90% Operating Hours For each 30 BOD) - 500 (All) * Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 510 (F-factor, Equations & Conversion Factors) - 500 (All) Count of F-factor Column Labels Row Labels Grand Total Grand Total * Type Code 520 (Minimum Data Not Obtained <22/30 BODs) - 500 (All) Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 530 (Excess Emissions During Emergency Conditions) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * Type Code 540 (Fuel Pre-treatment Credit SO2) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * TypeCode 550 (Changes in Operation in Control Equipment When CEM Data Not Available) - 500 (All) Column Labels Row Labels Grand Total Grand Total