Re: Intermountain Power Service Corporation (IPSC) – Pretest Protocol for Carbon Dioxide
(CO2), Flow, Nitrogen Oxides (NOx), Oxygen (O2), Sulfur Dioxide (SO2) Relative
Accuracy Test – Millard County
The Utah Division of Air Quality (DAQ) reviewed IPSC’s pretest protocol dated March 31, 2025,
and additional information submitted on May 2, 2025. The proposed test shall be performed under
the following conditions:
IPSC’s monitoring system to be certified:
Source Channel Manufacturer Model # Monitor SN Low Range High Range
Unit 3
O2 TECO 48iQ 12208416650 0% 25%
NOx TECO 42iQ 12127713452 0 ppm 10 ppm
NH3, NOx TECO 42iQ 12127713453 0 ppm 20 ppm
CO-L TECO 48iQ 12208416650 0 ppm 10 ppm
CO-H TECO 48iQ 12208416648 0 ppm 4000 ppm
Unit 4
O2 TECO 48iQ 12208416651 0% 25%
NOx TECO 42iQ 12127713454 0 ppm 10 ppm
NH3, NOx TECO 42iQ 12127713455 0 ppm 20 ppm
CO-L TECO 48iQ 12208416651 0 ppm 10 ppm
CO-H TECO 48iQ 12208416649 0 ppm 4000 ppm
IPSC, TIC, Mitsubishi, and Alliance Technical Group, LLC will conduct a relative
accuracy/performance specification test on IPSC’s continuous monitoring system.
6 à Û Ù Û Þ
DAQC-427-25
Page 2
Relative accuracy must be determined in the units of the emission standard or equivalent units of
the emission standard, i.e., tons/year shall be tested in pounds/hour.
The DAQ understands that testing will be conducted as follows:
Test Date Point Source Parameter EPA Reference Method
June 18-19, 2025 Unit 3 O2, CO2, NOx, and CO Method 3A, 7E, 10, and 19
Unit 4 O2, CO2, NOx, and CO Method 3A, 7E, 10, and 19
• Reference Method 3A - Determination of Oxygen and Carbon Dioxide
Concentrations in Emissions from Stationary Point Sources – (Instrumental
Analyzer Procedure) as outlined in 40 CFR 60 Appendix A.
• Reference Method 7E - Determination of Nitrogen Oxide Emissions from
Stationary Point Sources - (Instrumental Analyzer Procedure) as outlined in 40
CFR 60 Appendix A.
• Reference Method 10 - Determination of Carbon Monoxide Emissions from
Stationary Point Sources – (NDIR Instrumental Procedure) as outlined in 40 CFR
60 Appendix A.
• Reference Method 19 - Determination of Sulfur Dioxide Removal Efficiency and
Particulate Matter, Sulfur Dioxide, and Nitrogen Oxides Emission Rates as
outlined in 40 CFR 60 Appendix A.
• Deviations - The Director or the representative of the Director must be notified of
and approve deviations of the Reference Method test. Any deviation from these
conditions without approval from the DAQ may constitute rejection of these tests.
Acceptance of a protocol does not relieve the owner/operator and the testing
contractor from strict adherence to all applicable EPA methods, DAQ policies,
Utah Air Quality Rules (UAQR), and methods approved by the Director. Any
deviation from EPA methods, DAQ policies, UAQR, and methods approved by the
Director must be addressed separately and express written consent given prior to
commencement of testing.
• Field data (Point Source emission data and test data) shall be turned over to the
DAQ in a timely manner for review.
• The Director will determine the relative accuracy of each monitoring system based
on Point Source continuous emission monitoring data and test data acquired by the
staff member of the DAQ during the test.
• All test reports must be submitted to the Director not later than 60 days after
completion of the test.
DAQC-427-25
Page 3
• The test report shall include all raw calibration data, raw emission data with date,
time stamps.
Relative accuracy test reports must contain:
1. Point source continuous monitor, channel, manufacturer, and serial number,
2. Raw stack test data and continuous monitor data with date and time stamps.
3. Emission data reported in concentration (ppm or %) and units in the applicable
emission limit.
The DAQ requires that all test reports include a statement signed by a responsible official
certifying that:
1. Testing was conducted while the Point Source was operating at the rate and/or
conditions specified in the applicable approval order, operating permit, or federal
regulation.
2. During testing, the Point Source combusted fuels, used raw materials, and
maintained process conditions representative of normal operations, and operated
under such other relevant conditions specified by the Director.
3. Based on information and belief formed after reasonable inquiry, the statements
and information contained in the report are true, accurate, and complete.
Should you have any questions concerning this matter, contact me at (801) 536-4438 or by email
at rleishman@utah.gov.
Sincerely,
Rob Leishman, Environmental Scientist
Major Source Compliance Section
RL:rh