HomeMy WebLinkAboutDERR-2024-005615IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION PV VENT CAP 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 4/1/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 3/12/2024 Order Number: 2365044 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #29514, MKT 1606 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY, UT 84111 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2365044 Date: 3/12/2024 Site Name/ID: 7-ELEVEN #29514, MKT 1606 / 29514 Address: 309 EAST 400 SOUTH State ID 4001444 City: SALT LAKE CITY State: UT Zip: 84111 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 Regular RUL 2 Pressure 50 10:04 10:34 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 TNK2 Regular RUL Pressure 50 10:04 10:34 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 TNK3 Premium PUL Pressure 50 10:04 10:34 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #29514, MKT 1606 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY UT 84111 29514 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 03/12/2024 RUL 2 RUL Veeder Root PLLD Veeder Root PLLD Veeder Root PLLDPLLDPLLDPLLD 30 2 30 2 2 30 UT151 David Mathie NW1-2365044 PUL TTNK1 Regular:1 TTNK2 Regular:1 TTNK3 Premium:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2365044 Date:3/12/2024 Site Name/ID:7-ELEVEN #29514, MKT 1606 Address:309 EAST 400 SOUTH State ID 4001444 City:SALT LAKE CITY State:UT Zip:84111 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #29514, MKT 1606 7-ELEVEN, INC. 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY UT 84111 4001444 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 03/12/2024 1 2 3 RU2 RUL PUL VR350 VR350 VR350 12033 12033 12033 97.9 96 96 81 81 81 1.5 1.5 1.5 UT151 David Mathie PVVC tested ==>RU2 Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>523V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.00 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 0.00 Fail PVVC tested ==>RU2 Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.59 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.13 Pass PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>523V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.00 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 0.00 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.64 Pass Neg Leak Rate (CFH)0.21 17 0.0360 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.01 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>523V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.00 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 0.00 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.60 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.08 Pass 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0360 Total -ve LR: 0.1017 Test Date 3/12/2024 Technician Name David Mathie WO #2365044 Facility Name / Loc #7-ELEVEN #29514, MKT 1606 29514 Street 309 EAST 400 SOUTH State ID 4001444 City, St, Zip SALT LAKE CITY, UT 84111 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2365044 Site ID / Name:29514 / 7-ELEVEN #29514, MKT 1606 Address:309 EAST 400 SOUTH State ID 4001444 City:SALT LAKE CITY State:UT Zip:84111 W.O.# NW1-2365044 +AAE- I10100 MAR 12, 2024 11:06 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I10100 MAR 12, 2024 11:06 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 MAR 12, 2024 11:07 AM SOFTWARE REVISION LEVEL VERSION 333.04 SOFTWARE+ACM- 346333-100-E CREATED - 13.06.07.08.25 S-MODULE+ACM- 330160-162-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV +AAMAAQ- I11B00 MAR 12, 2024 11:07 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SERVICE NOTICE SESSION REPORT START TIME END TIME MAR 12, 2024 9:33 AM MAR 12, 2024 10:46 AM +AAMAAQ- I20100 MAR 12, 2024 11:07 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 RU2 SOUTH 5950 5983 5874 46.51 0.00 51.83 2 RUL MIDDLE 7971 8010 3809 60.12 0.00 52.81 3 PUL 3802 3816 8231 33.92 0.00 54.63 +AAMAAQ- I20600 MAR 12, 2024 11:07 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 TANK ALARM HISTORY TANK 1 RU2 SOUTH HIGH WATER ALARM MAR 12, 2024 10:13 AM OVERFILL ALARM MAR 12, 2024 10:21 AM LOW PRODUCT ALARM AUG 11, 2023 9:35 PM INVALID FUEL LEVEL MAR 12, 2024 10:10 AM AUG 12, 2023 12:36 PM HIGH WATER WARNING MAR 12, 2024 10:13 AM DELIVERY NEEDED MAR 12, 2024 10:22 AM MAR 12, 2024 10:10 AM AUG 11, 2023 2:03 PM LOW TEMP WARNING MAR 12, 2024 10:27 AM TANK 2 RUL MIDDLE HIGH WATER ALARM MAR 12, 2024 10:15 AM OVERFILL ALARM MAR 12, 2024 10:23 AM INVALID FUEL LEVEL MAR 12, 2024 10:12 AM HIGH WATER WARNING MAR 12, 2024 10:15 AM DELIVERY NEEDED MAR 12, 2024 10:23 AM MAR 12, 2024 10:12 AM LOW TEMP WARNING MAR 12, 2024 10:28 AM TANK 3 PUL HIGH WATER ALARM MAR 12, 2024 10:17 AM OVERFILL ALARM MAR 12, 2024 10:24 AM LOW PRODUCT ALARM AUG 11, 2023 4:25 PM INVALID FUEL LEVEL AUG 15, 2023 3:47 PM HIGH WATER WARNING MAR 12, 2024 10:17 AM DELIVERY NEEDED MAR 12, 2024 10:14 AM AUG 30, 2023 9:03 AM AUG 22, 2023 6:02 PM CSLD INCR RATE WARN MAY 4, 2023 2:29 AM MAR 27, 2023 7:06 AM LOW TEMP WARNING MAR 12, 2024 10:29 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 +AAMAAQ- I20700 MAR 12, 2024 11:07 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 TANK LEAK TEST HISTORY T 1:RU2 SOUTH LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 7:18 AM 6019 50.0 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 6:10 AM 26 7187 59.7 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 4, 2024 8:24 AM 26 7898 65.6 CSLD FEB 22, 2024 4:44 AM 24 7260 60.3 CSLD MAR 11, 2024 5:28 AM 26 7271 60.4 CSLD APR 21, 2023 9:56 AM 2 9414 78.2 STANDARD MAY 3, 2023 2:09 AM 23 7356 61.1 CSLD JUN 8, 2023 1:20 AM 25 6709 55.8 CSLD JUL 31, 2023 5:03 AM 28 6534 54.3 CSLD AUG 1, 2023 7:42 PM 27 6712 55.8 CSLD SEP 30, 2023 1:36 AM 27 6876 57.1 CSLD OCT 6, 2023 3:32 AM 25 7579 63.0 CSLD NOV 13, 2023 4:13 AM 26 7883 65.5 CSLD DEC 25, 2023 8:34 AM 26 8027 66.7 CSLD TANK LEAK TEST HISTORY T 2:RUL MIDDLE LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 8:19 AM 8029 66.7 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 9:10 AM 31 8708 72.4 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 1, 2024 3:22 AM 31 9647 80.2 CSLD FEB 4, 2024 6:45 PM 31 9253 76.9 CSLD MAR 7, 2024 5:59 AM 30 9451 78.5 CSLD APR 30, 2023 12:02 AM 31 8985 74.7 CSLD MAY 13, 2023 4:02 AM 35 9037 75.1 CSLD JUN 25, 2023 5:01 PM 31 8081 67.2 CSLD JUL 25, 2023 7:18 AM 31 8751 72.7 CSLD AUG 1, 2023 3:00 AM 35 7955 66.1 CSLD SEP 12, 2023 12:16 PM 31 7929 65.9 CSLD OCT 23, 2023 4:39 PM 40 9623 80.0 CSLD NOV 28, 2023 4:11 PM 39 9356 77.8 CSLD DEC 27, 2023 8:50 AM 31 10106 84.0 CSLD TANK LEAK TEST HISTORY T 3:PUL LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 7:17 AM 3875 32.2 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 12, 2024 6:10 AM 26 4743 39.4 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 28, 2024 6:29 AM 30 7327 60.9 CSLD FEB 5, 2024 4:34 AM 27 7167 59.6 CSLD MAR 1, 2024 3:11 AM 27 6005 49.9 CSLD APR 21, 2023 9:56 AM 2 4320 35.9 STANDARD MAY 21, 2023 7:42 AM 25 6803 56.5 CSLD JUN 1, 2023 4:02 AM 25 6010 50.0 CSLD JUL 17, 2023 10:13 AM 25 2744 22.8 CSLD AUG 1, 2023 2:37 AM 27 2619 21.8 CSLD SEP 26, 2023 6:27 AM 28 4069 33.8 CSLD OCT 6, 2023 3:32 AM 27 4392 36.5 CSLD NOV 28, 2023 11:10 PM 30 4567 38.0 CSLD DEC 24, 2023 2:52 AM 29 6146 51.1 CSLD +AAMAAQ- IA0100 MAR 12, 2024 11:07 AM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 RU2 SOUTH MAG C000 96.00 494709 2404 TANK 2 RUL MIDDLE MAG C000 96.00 494711 2404 TANK 3 PUL MAG C000 96.00 494710 2404 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: RU2 SOUTH PRODUCT CODE 1 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 97.90 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 932 TANK 2 SETUP CONDITIONS PRODUCT: RUL MIDDLE PRODUCT CODE 2 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 96.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 933 TANK 3 SETUP CONDITIONS PRODUCT: PUL PRODUCT CODE 3 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 96.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I62A00 MAR 12, 2024 11:08 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 RU2 SOUTH 6016 2 RUL MIDDLE 6016 3 PUL 6016 4 0 +AAMAAQ- I63600 MAR 12, 2024 11:08 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 RU2 SOUTH 3008 2 RUL MIDDLE 3008 3 PUL 3008 4 0 +AAMAAQ- I61100 MAR 12, 2024 11:08 AM LEAK TEST METHOD - - - - - - - - - - - - TEST CSLD : ALL TANK Pd +AD0- 95+ACU- CLIMATE FACTOR:EXTREME EVAP COMP: NO GROSS TEST AUTO-CONFIRM: ENABLED REPORT ONLY: DISABLED TST EARLY STOP:DISABLED +AAMAAQ- I78000 MAR 12, 2024 11:08 AM PRESSURE LINE LEAK SETUP Q 1:RU2 TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 200 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 1:RU2 SOUTH DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:RUL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 300 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 2:RUL MIDDLE DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET:-2.0PSI MECHANICAL BLENDER: NO Q 3:PUL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 220 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 3:PUL DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO +AAMAAQ- I7BD00 MAR 12, 2024 11:08 AM PRESSURE LLD SETUP REPORT Q 1:RU2 - NO ALARM ASSIGNMENTS - Q 2:RUL - NO ALARM ASSIGNMENTS - Q 3:PUL - NO ALARM ASSIGNMENTS - +AAMAAQ- I10200 MAR 12, 2024 11:08 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164087 164175 2 PLLD SENSOR BD 3937 3931 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 PLLD POWER BD 100879 101122 10 UNUSED 15000000 15000000 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 ELEC DISP INT. 101466 101604 COMM 2 UNUSED 15000000 15000000 COMM 3 SERIAL SAT BD 486432 487858 COMM 4 UNUSED 15000000 15000000 COMM 5 RS485 SERIAL BD 69297 69556 COMM 6 MT COMM BOARD 410731 411819 +AAM-