Loading...
HomeMy WebLinkAboutDERR-2024-005115 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 PRODUCT PIPING INTEGRITY TESTING Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/22/24 This procedure is to test the integrity of product piping. Tests were performed with Petro-Tite line tester. Tank Number 1 (NE) 2 (SW) 2a 3 (NW) 1b 4 (SE) 2b Product Stored RUL MUL PUL DSL Piping Run Only Out Only Out Piping Type FRP of FRP of Test Pressure (PSI) 50 Service 50 Service Test Duration (minutes) 30 30 Leak Rate (GPH) 0.004 0.004 Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: T2 – MUL – is out of service Tester’s Name Taber DeHart, UT-0394 Tester’s Signature MU L PU L DS L RU L WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 MECHANICAL AND ELECTRONIC LINE LEAK DETECTOR PERFORMANCE TESTS Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/22/24 This data sheet can be used to test the mechanical line leak detector (MLLD) and electronic line leak detector (ELLD) with submersible turbine pump (STP) systems. See PEI/RP 1200 Sections 9.1 and 9.2 for test procedures. Line Number 1 2 3 4 Product Stored RUL MUL PUL DSL Leak Detector Manufacturer Red Jacket Red Jacket Leak Detector Model FX1V FX1V Type Of leak Detector ☒MLLD ☐ELLD ☐MLLD ☐ELLD ☒MLLD ☐ELLD ☐MLLD ☐ELLD MLLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure 28 Out 24 Out Check valve holding pressure 14 Of 16 Of Line resiliency (ml) (line bleedback volume as measured from check valve holding pressure to 0 psig) 65 Service 65 Service Step through time in seconds (time the MLLD hesitates at metering pressure before going to full operating pressure as measured from 0 sig with no leak induced on the line) 1 1 Metering pressure (STP pressure when simulated leak rate 3 gph at 10 psig) 10 10 Opening time in seconds (the time the MLLD opens to allow full pressure after simulated leak is stopped) 1 1 Does the STP pressure remain at or below the metering pressure for at least 60 seconds when the simulated leak is induced? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Does the leak detector reset (trip) when the line pressure is bled off to zero psig? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Does STP properly clycle on/off under normal fuel system operating conditions? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No A "No" answer to any of the above questions indicates that the MLLD fails the test. ELLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure How many test cycles are observed before alarm/shutdown occurs? Does the simulated leak cause on alarm? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to the above question indicates that the ELLD fails the test. Does the simulated leak cause an STP shutdown? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/22/24 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. Tank Number 1 2 3 4 Product Stored RUL MUL PUL DSL ATG Brand and Model TLS 350 Out TLS 350 Out 1. Tank Volume, gallons 8,272 Of 5,264 Of 2. Tank Diameter, inches 96 Service 96 Service 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 4. Float moves freely on the stem without binding? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 5. Fuel float level agree with the value programmed into the console? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 6. Water float level agree with the value programmed into the console? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 7. Inch level from the bottom of the stem when 90% alarm is triggered? 80 7/8 80 7/8 8. Inch level at which the overfill alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 9. Inch level from the bottom when the water float first triggers an alarm? 1.5 1.5 10. Inch level at which the water float alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No If any answers in Lines 3, 4, 5, or 6 are "No" the system has failed the test. Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 SPILL BUCKET INTEGRITY TESTING HYDROSTATIC TEST METHOD SINGLE- AND DOUBLE-WALLED VACUUM TEST METHOD Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/22/24 This procedure is to test the leak integrity of single- and double-walled spill buckets. See PEI/RP1200 Section 6.2 for hydrostatic test method, Section 6.3 for single-walled vacuum test method and Section 6.4 for double-walled vacuum test method. Tank Number 1 2 3 4 Product Stored RUL MUL PUL DSL Spill Bucket Capacity 5-Gallon Out of 5-Gallon Out of Manufacturer OPW Service OPW Service Construction ☒Double-walled ☐Single-walled ☐Double-walled ☐Single-walled ☒Double-walled ☐Single-walled ☐Double-walled ☐Single-walled Test Type ☐Hydrostatic ☒Vacuum ☒Double-walled ☐Single-walled ☐Hydrostatic ☐Vacuum ☐Double-walled ☐Single-walled ☐Hydrostatic ☒Vacuum ☒Double-walled ☐Single-walled ☐Hydrostatic ☐Vacuum ☐Double-walled ☐Single-walled Spill Bucket Type ☒Product ☐Vapor ☐Product ☐Vapor ☒Product ☐Vapor ☐Product ☐Vapor Liquid and debris remove from spill bucket?* ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Visual Inspection (no cracks, loose parts or separation of the bucket from the fill pipe.) ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Tank Riser cap included in test? ☐Yes ☐No ☒NA ☐Yes ☐No ☐NA ☐Yes ☐No ☒NA ☐Yes ☐No ☐NA Drain valve included in test? ☐Yes ☐No ☒NA ☐Yes ☐No ☐NA ☐Yes ☐No ☒NA ☐Yes ☐No ☐NA Starting Level 15” 15” Test Start Time 10:58 11:04 Ending Level 14” 13.5” Test End Time 11:03 11:09 Test Period 5-Minute 5-Minute Level Change -1” -1.5” Pass/fail criteria: Must pass visual inspection. Hydrostatic: Water level drop of less than 1/8 inch; Vacuum single-walled only: Maintain at least 26 inches water column; Vacuum double-walled: maintain at least 12 inches water column. Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: *All liquids and debris must be disposed of properly Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 UST OVERFILL EQUIPMENT INSPECTION AUTOMATIC SHUTOFF DEVICE AND BALL FLOAT VALVE Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/22/24 This data sheet is for inspecting automatic shutoff devices and ball float valve. See PEI/RP1200 Section 7 for inspection pro cedures. Product Grade RUL MUL PUL DSL Tank Number 1 2 3 4 Tank Volume, gallons 8,272 Out 5,264 Out Tank Diameter, inches 96 of 96 of Overfill Prevention Device Brand OPW Service OPW Service Type ☒ Automatic Shutoff Device☐ Ball Float Valve ☐ Automatic Shutoff Device ☐ Ball Float Valve ☒ Automatic Shutoff Device ☐ Ball Float Valve ☐ Automatic Shutoff Device ☐ Ball Float Valve AUTOMATIC SHUTOFF DEVICE INSPECTION 1. Drop tube removed from tank? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 2. Drop tube and float mechanisms free of debris? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 3. Float moves freely without binding and poppet moves into flow path? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 4. Bypass valve in the drop tube open and free of blockage (if present)? ☒Yes ☐No ☐Not Present ☐Yes ☐No ☐Not Present ☒Yes ☐No ☐Not Present ☐Yes ☐No ☐Not Present 5. Flapper adjusted to shut off flow at 95% capacity? * ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No A "No" to any item in Lines 1-5 indicates a test failure. BALL FLOAT VALVE INSPECTION** 1. Tank top fitting vapor-tight and leak free? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No 2. Ball float cage free of debris? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No 3. Ball free of holes and cracks and moves freely in cage? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No 4. Vent hole in pipe open and near top of tank? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No 5. Ball float pipe proper length to restrict flow to 90% capacity? *** ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" to any item in Lines 1-5 indicates a test failure. Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: *Use manufacturer’s suggested procedure for determining if automatic shutoff device will shut off flow at 95% capacity. **If a ball float valve is found to fail the inspection, another method of overfill must be used. ***Use manufacturer’s suggested procedure for determining if flow restriction device will restrict flow at 90% capacity. Tester’s Name Taber DeHart, UT-0394 Tester’s Signature Overfill Prevention Equipment Inspection OPW 61 and 71 Series Overfill Prevention Device Inspection (Non Testable) Customer Name: Facility ID #: Address: Street Date: City, State Tank Designation RUL PUL Part 1 - Proper Height Setting Calculation YES NO OPW Installation Manual H15524PA Rev L 1/30/2014) Maximum Tank Volume (Gallons) Shown on customers provided tank chart Gallons 8,272 5,264 Max Shut off requirement for flapper is 95% %95%95% Multiply maximum tank volume by 95% (Gallons)95%Gallons 7,858 5,001 Find the dip stick number on the tank chart that corresponds with 95%X Inches 86.625''86.625'' Measure top of fill riser threads, or face seal adapter A Inches 32.750''33.750'' Find the Dip Stick Volume that corresponds with 100% (FROM TANK CHART)Y Inches 96.000''96.000'' Upper Tube in tank (Y) -(X) = (Z)Z Inches 9.375''9.375'' Subtract 2 inches from upper tube in tank Formula: (Z) - 2" = (C )C Inches 7.375''7.375'' Calculated minimum upper tube length Formula: (C ) + (A) = Upper Tube Length Calculated Inches 40.125''41.125'' Actual measured upper tube length (without fill adapter)Actual Inches 40.875''41.750'' Part 2 - Device Certification Citeria Evaluation Criteria 1 Does the overfill prevention device meet the 95% requirement?YES YES (If Actual is greater than or equal to calculated ( YES) (If Actual is less than or equal to calculated ( NO) Criteria 2 Is the actual measured upper tube length 6.5 inches or more than the fill riser?YES YES (C must be 6.5" if not then the upper tube length is 6.5 plus measurement A) (For testable models ending in "T" upper tube length is (C)+ (A) - 1 -1/2". If less than 6.5" than it is 6.5" +(A) - 1-1/2") Criteria 3 Does the overfill prevention device function function as required?YES YES (Inspect the device for damage, contamination, freedom of movement, weakening due to wear and corrosion) Part 3 - Device Certification PASS / FAIL PASS PASS Technician certifies that the device is operationally compliant. If the response to Criteria 1, 2, and 3 above are YES. Date: Fast Break 4001552 379 Soth 300 West Salt Lake City, Utah 841012/22/2024 OPW 71SO-410C Overfill Drop Tube Make and Model Tank Chart Comments: 2/22/2024 Signature of Technician: Tank Chart Provided by