HomeMy WebLinkAboutDAQ-2025-0023101
DAQC-PBR155730001-25
Site ID 15573 (B1) MEMORANDUM
TO: FILE – SM ENERGY COMPANY – Hamaker 3-12B1
THROUGH: Rik Ombach, Minor Source Oil and Gas Section Manager
FROM: Chris Jensen, Environmental Scientist
DATE: April 30, 2025
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: April 29, 2025
SOURCE LOCATION: Lat: -109.9448394 Long: 40.3235816
Uintah County
Business Office:
SM Energy Company
1700 Lincoln Street, Suite 3200 Suite 390
Denver, CO 80203
SOURCE TYPE: Tank Battery
API: 4304752294
SOURCE CONTACTS: James Lebeck, Corporate Environmental Contact
Phone: 303-830-5855, Email: jlebeck@sm-energy.com
Ryan Sokolowski, Field Contact
Phone: 574-360-7168, Email: rsokolowski@sm-energy.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go
through a separator where the oil and any water products are sent
to storage tanks and the gas is used to power equipment on site
(pump jack engine, tank heater, separator, flare, combustor, etc.)
Any remaining gas is sent to a pipeline that feeds a local gas plant.
The oil and process water in the storage tanks is loaded into tanker
trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and
Gas Industry, and UAC R307-201: Emission Standards: General
Emission Standards; and UAC R307-150: Emission Inventories.
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
No Flare Controls, Site has Line Power.
The source registered: 8,671 Estimated Oil BBL.
DOGM current 12 month rolling production is: 2,366 BBLs.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
# - $ . ) . )
2
REGISTERED EQUIPMENT: Tank
General Provisions Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines 0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile source dust 10%. [ R307-201-3] In Compliance. No visible emissions were detected by use of the USEPA Method 9. VOC emissions are, at all times, minimized as reasonably practicable by equipment design, maintenance and operation practices. [R307-501-4(1)] In Compliance. Associated gas is routed to a sales gathering line. Tanks all have thief hatches and PRV's that are closed and not leaking. The expected components were found installed. The DAQ observed the installation for a cycle and it seems to be operating as expected. All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as applicable. Tagging and record keeping requirements are not required. [R307-502-4] In Compliance. The natural gas-driven pneumatic controllers at this source are not continuous bleed but are low-bleed or snap acting. Tank Truck Loading Truck loading is done by bottom filling or submerged fill pipe. [R307-504(1)] In Compliance. The truck loading area is suitable for submerged loading and it is routine for truck drivers to load this way. Storage Vessels Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. All hatches were found closed at the start of the evaluation. Vessel Vent Components: (valves, unions, pressure relief devices, etc.) are leak-free, in good repair, and working as intended. (Tank covers are leak free and form a continuous seal.). [R307-501-4] In Compliance. No leaking components were found during the survey. The components were all operated and installed as expected. Natural Gas Engines Temporary Emergency Generators, in use for less than 100 days, have an operational hour meter and log book (onsite) recording hours used and maintenance performed. [40 CFR 60 Subpart IIII, JJJJ] In Compliance. No generator is installed. Associated Gas Flaring Associated gas is routed to a process unit for combustion, a sales pipeline or an operating VOC control device, except in an emergency. An emergency release is unanticipated, temporary, infrequent, unavoidable, =24 hrs. and is not due to operator negligence. Low pressure gas from working loss, breathing loss and oil flashing is not "associated gas". [R307-511-4(1)] In Compliance. Associated gas is gathered to a sales line.
3
Recordkeeping Requirements Emission Inventory An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The operator submitted for the 2023 emissions inventory. Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. Associated gas Flaring The following records are kept: The time and date of event Volume of emissions Any corrective action taken for 3 years. [R307-511-5(1)(a)(b)] In Compliance. No reported events.
PREVIOUS ENFORCEMENT
ACTIONS: None in the past 5 years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance.
The source was surveyed by AVO and with an OGI camera and
was found to be well-kept with no visible or fugitive emissions.
The DAQ conducted a review of the rules requiring recordkeeping
and looked for installation/operation issues. The operator's
representatives were pleasant and cooperative. Requested records
were provided in a timely manner and reviewed at the local field
office.
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no recommendations for the next inspector other
than what are customary. The DAQ was joined by SME personnel
during the site inspection.
RECOMMENDATIONS FOR NSR: None
ATTACHMENTS: None