DERR-2024-004253
Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 12/21/2023 Tanknology WO#NW1-2363775 Test Purpose COMPLIANCE Customer PO# Customer Location PENSKE TRUCK LEASING P.O. BOX 7635 READING, PA 19603 PENSKE TRUCK UT-001 2211 S 2000 W Salt Lake City, UT 84119 Attn: Environmental Services Attn: PHIL OR MIKE (610) 775-6298 (801) 972-9544 Test / Inspection Description Item Tested Date Tested Result Precision Line Tightness (.1 GPH) Tank DSL Line 1 Low Sulfur Diesel 12/21/2023 Pass Precision Line Tightness (.1 GPH) Tank UNLD Line 1 REG UNLEAD 12/21/2023 Pass Precision Line Tightness (.1 GPH) Satellite Line 1 12/21/2023 Pass Precision Line Tightness (.1 GPH) Satellite Line 2 12/21/2023 Pass PEI RP 1200 Leak Detector See test report for details 12/21/2023 Pass Impact Valve Inspection See test report for details 12/21/2023 Pass RP 1200 ATG See test report for details 12/21/2023 Pass RP 1200 Sensors See test report for details 12/21/2023 Pass Pressure Vacuum Vent Cap See test report for details 12/21/2023 Pass Sump Inspection See test report for details 12/21/2023 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) Product Line Tightness Test Page 1 of 1 Work Order: 2363775 Date: 12/21/2023 Site Name/ID: PENSKE TRUCK UT-001 / UT-001 Address: 2211 S 2000 W City: Salt Lake City State: UT Zip: 84119 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 DSL Low Sulfur Diesel Pressure 70 10:51 11:51 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 UNLD REG UNLEAD Pressure 70 10:51 11:51 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Product Line Tightness Test Satellite Line Tightness Test Page 1 of 1 Work Order: 2363775 Date: 12/21/2023 Site Name/ID: PENSKE TRUCK UT-001 / UT-001 Address: 2211 S 2000 W City: Salt Lake City State: UT Zip: 84119 Satellite Line # Fueling From - To Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Sat # 1 2 - 2A Low Sulfur Diesel Pressure 70 10:51 11:51 0.00 Pass Yes Sat # 2 3 - 3A Low Sulfur Diesel Pressure 70 10:51 11:51 0.00 Pass Yes Sat # Sat # Sat # Sat # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com PENSKE TRUCK UT-001 2211 S 2000 W Salt Lake City UT 84119 UT-001 Tanknology, Inc. PENSKE TRUCK LEASING P.O. BOX 7635 READING PA 19603 610-775-6298 12/21/2023 Low Sulfur DieselREG UNLEAD Veeder Root FX1DV Veeder Root FX1VFX1DVFX1V 45 15 150 2 12 3 28 25 100 2 10 3 UT151 David Mathie NW1-2363775 TDIE:1 TREGUNLD:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2363775 Date:12/21/2023 Site Name/ID:PENSKE TRUCK UT-001 Address:2211 S 2000 W City:Salt Lake City State:UT Zip:84119 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/ 85 Pass Fail Not Tested 2/ 40 Pass Fail Not Tested 2A/ 40 Pass Fail Not Tested 3/ 40 Pass Fail Not Tested 3A/ 40 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com PENSKE TRUCK UT-001 PENSKE TRUCK LEASING 2211 S 2000 W Salt Lake City UT 84119 UT-001 Tanknology, Inc. P.O. BOX 7635 READING PA 19603 610-775-6298 800-964-1250 12/21/2023 1 2 DSL RUL VR350 VR350 20073 12068 119.75 119.75 101 101 1.8 1 UT151 David Mathie 2211 S 2000 W PENSKE TRUCK UT-001 2211 S 2000 W , Salt Lake City, UT 84119 UT-001 Tanknology, Inc. PENSKE TRUCK LEASING P.O. BOX 7635 READING, PA 19603 610-775-6298 12/21/2023 STP STP UDC UDC UDC UDC UDC DSL RUL 1 2 SAT 2 3 3A UT151 David Mathie PVVC tested ==>GAS Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>523V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.00 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 0.00 Fail PVVC tested ==>GAS Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.62 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.86 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0127 Total -ve LR: 0.0339 Test Date 12/21/2023 Technician Name David Mathie WO #2363775 Facility Name / Loc #PENSKE TRUCK UT-001 UT-001 Street 2211 S 2000 W City, St, Zip Salt Lake City, UT 84119 Pressure Vacuum Vent Cap Test Form TP-201.1E ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 12/21/2023 UST Facility Person Conducting Test Facility Name PENSKE TRUCK UT-001 Facility ID # UT-001 Tester's Name DMATHIE Physical Address 2211 S 2000 W Company Tanknology Inc. City Salt Lake City County SALT LAKE State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner PENSKE TRUCK LEASING Tester's Signature Date 12/21/2023 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2023 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:DSL Low Sulfur Diesel - 1 NA Y Y Y N Pass STP:UNLD REG UNLEAD - 1 NA Y Y Y N Pass Comments: WO: 2363775 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2363775 Site ID / Name:UT-001 / PENSKE TRUCK UT-001 Address:2211 S 2000 W City:Salt Lake City State:UT Zip:84119 W.O.# NW1-2363775 +AAE-i101002312211043140408+ACYAJg-FB34+AAMAAQ- I10100 DEC 21, 2023 10:43 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 SYSTEM STATUS REPORT D 8:ALARM CLEAR WARNING +AAMAAQ- I90200 DEC 21, 2023 10:43 AM SOFTWARE REVISION LEVEL VERSION 122.00 SOFTWARE+ACM- 346122-100-A CREATED - 01.10.16.09.35 S-MODULE+ACM- 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD +AAMAAQ- I20100 DEC 21, 2023 10:43 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 DIESEL 9259 9275 10814 56.23 1.01 55.97 2 UNLEADED 4079 4076 7989 44.47 0.00 61.19 +AAMAAQ- I30100 DEC 21, 2023 10:43 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 DIESEL SUMP SENSOR NORMAL 2 UNLEADED SUMP SENSOR NORMAL 3 UNL DISP SUMP SENSOR NORMAL 4 DSL 2 HELPER SUMP SENSOR NORMAL 5 DSL 2 DISP SUMP SENSOR NORMAL 6 DSL 3 DISP SUMP SENSOR NORMAL 7 DSL 3 HELPER SUMP SENSOR NORMAL +AAMAAQ- I30200 DEC 21, 2023 10:43 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DIESEL SUMP DEC 21, 2023 9:16 AM FUEL ALARM DEC 21, 2022 11:36 AM FUEL ALARM JAN 7, 2022 11:59 AM FUEL ALARM 2 UNLEADED SUMP DEC 21, 2023 9:16 AM FUEL ALARM APR 25, 2023 12:07 PM FUEL ALARM APR 6, 2023 7:32 AM FUEL ALARM 3 UNL DISP SUMP DEC 21, 2023 9:14 AM FUEL ALARM DEC 21, 2022 11:38 AM FUEL ALARM JAN 7, 2022 12:02 PM FUEL ALARM 4 DSL 2 HELPER SUMP DEC 21, 2023 9:15 AM FUEL ALARM DEC 21, 2022 11:38 AM FUEL ALARM JAN 7, 2022 12:02 PM FUEL ALARM 5 DSL 2 DISP SUMP DEC 21, 2023 9:15 AM FUEL ALARM DEC 21, 2022 11:39 AM FUEL ALARM JAN 7, 2022 12:44 PM FUEL ALARM 6 DSL 3 DISP SUMP DEC 21, 2023 9:15 AM FUEL ALARM DEC 21, 2022 11:39 AM FUEL ALARM JAN 7, 2022 12:03 PM FUEL ALARM 7 DSL 3 HELPER SUMP DEC 21, 2023 9:15 AM FUEL ALARM MAR 23, 2023 5:04 AM FUEL ALARM DEC 27, 2022 10:04 AM FUEL ALARM +AAMAAQ- I20600 DEC 21, 2023 10:43 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 TANK ALARM HISTORY TANK 1 DIESEL HIGH WATER ALARM DEC 21, 2023 9:23 AM DEC 21, 2022 11:47 AM JAN 7, 2022 12:01 PM OVERFILL ALARM DEC 21, 2023 9:29 AM DEC 21, 2022 12:01 PM JAN 7, 2022 12:23 PM LOW PRODUCT ALARM DEC 21, 2023 9:43 AM DEC 21, 2023 9:30 AM DEC 21, 2023 9:19 AM HIGH PRODUCT ALARM JAN 7, 2022 12:15 PM MAR 10, 2021 10:16 AM MAR 24, 2020 1:55 PM INVALID FUEL LEVEL DEC 21, 2023 9:20 AM DEC 21, 2022 11:42 AM JAN 7, 2022 11:58 AM PROBE OUT DEC 21, 2023 9:30 AM DEC 21, 2023 9:20 AM DEC 21, 2022 12:04 PM HIGH WATER WARNING DEC 21, 2023 9:23 AM DEC 21, 2022 11:47 AM JAN 7, 2022 12:01 PM DELIVERY NEEDED DEC 21, 2023 9:30 AM DEC 20, 2023 9:53 AM DEC 8, 2023 1:58 PM MAX PRODUCT ALARM JAN 7, 2022 12:15 PM MAR 10, 2021 10:16 AM MAR 24, 2020 1:55 PM CSLD INCR RATE WARN FEB 16, 2008 1:08 PM JAN 27, 2008 12:50 AM JAN 20, 2008 4:01 AM LOW TEMP WARNING MAR 29, 2019 8:55 AM JAN 12, 2017 11:04 PM DEC 21, 2016 4:26 PM TANK 2 UNLEADED HIGH WATER ALARM DEC 21, 2023 9:24 AM DEC 21, 2022 11:48 AM JAN 7, 2022 12:02 PM OVERFILL ALARM DEC 21, 2023 9:29 AM DEC 21, 2022 11:58 AM JAN 7, 2022 12:17 PM LOW PRODUCT ALARM DEC 21, 2023 9:30 AM DEC 21, 2023 9:20 AM MAY 30, 2023 11:00 AM HIGH PRODUCT ALARM JAN 7, 2022 12:22 PM MAR 10, 2021 10:16 AM MAR 24, 2020 1:55 PM INVALID FUEL LEVEL DEC 21, 2023 9:21 AM JAN 7, 2022 11:59 AM MAR 10, 2021 10:02 AM PROBE OUT DEC 21, 2023 9:31 AM DEC 21, 2023 9:20 AM DEC 21, 2022 12:01 PM HIGH WATER WARNING DEC 21, 2023 9:24 AM DEC 21, 2022 11:48 AM JAN 7, 2022 12:02 PM DELIVERY NEEDED DEC 21, 2023 9:30 AM DEC 21, 2023 9:20 AM NOV 25, 2023 8:10 AM MAX PRODUCT ALARM JAN 7, 2022 12:22 PM MAR 10, 2021 10:16 AM MAR 24, 2020 1:56 PM PERIODIC TEST FAIL JUL 31, 2009 7:32 PM JUL 31, 2009 11:45 AM JUL 31, 2009 12:41 AM LOW TEMP WARNING DEC 21, 2022 12:02 PM MAR 29, 2019 8:56 AM MAR 23, 2018 10:43 AM +AAMAAQ-9999FF1B+AAMAAQ- I20201 DEC 21, 2023 10:44 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 DELIVERY REPORT T 1:DIESEL INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT END: DEC 21, 2023 9:52 AM 5057 5054 0.80 60.82 35.88 START: DEC 21, 2023 9:43 AM 3802 3800 0.00 60.84 29.27 AMOUNT: 1255 1254 END: DEC 21, 2023 9:42 AM 5065 5062 0.76 60.91 35.93 START: DEC 21, 2023 9:36 AM 4945 4943 0.00 60.89 35.31 AMOUNT: 120 119 END: DEC 21, 2023 9:36 AM 18498 18533 0.78 55.81 103.90 START: DEC 21, 2023 9:27 AM 1028 1027 5.15 60.73 11.84 AMOUNT: 17470 17506 END: DEC 11, 2023 8:03 AM 14886 14951 0.85 50.18 83.20 START: DEC 11, 2023 7:24 AM 5061 5052 1.01 63.58 35.91 AMOUNT: 9825 9899 END: NOV 30, 2023 1:41 PM 15132 15162 0.86 55.62 84.46 START: NOV 30, 2023 1:05 PM 7089 7071 0.87 65.23 45.94 AMOUNT: 8043 8091 END: NOV 21, 2023 5:45 PM 15201 15214 0.84 57.92 84.81 START: NOV 21, 2023 5:01 PM 5249 5232 0.86 67.31 36.87 AMOUNT: 9952 9982 END: NOV 13, 2023 5:28 PM 15457 15434 0.86 63.32 86.14 START: NOV 13, 2023 4:47 PM 5443 5422 0.85 68.16 37.84 AMOUNT: 10014 10012 END: NOV 7, 2023 9:02 AM 14104 14104 0.85 59.83 79.28 START: NOV 7, 2023 8:10 AM 4153 4135 0.93 69.54 31.17 AMOUNT: 9951 9969 END: OCT 30, 2023 12:19 PM 14788 14769 0.87 62.84 82.70 START: OCT 30, 2023 11:40 AM 4889 4863 0.87 71.58 35.02 AMOUNT: 9899 9906 END: OCT 20, 2023 1:20 PM 15237 15147 0.85 72.99 85.00 START: OCT 20, 2023 12:44 PM 7335 7291 0.82 73.04 47.12 AMOUNT: 7902 7856 +AAMAAQ- IA0100 DEC 21, 2023 10:44 AM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 DIESEL MAG C000 120.00 044978 5132 TANK 2 UNLEADED MAG C000 120.00 044980 5132 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: DIESEL PRODUCT CODE 1 HIGH WATER LIMIT 1.8 OVERFILL LIMIT: 18065 HIGH PRODUCT LIMIT: 19069 LOW PRODUCT: 3970 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 3 THERMAL COEFF: 0.000450 DELIVERY DELAY: 5 TANK FULL CAPACITY: 20073 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 119.75 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 932 TANK 2 SETUP CONDITIONS PRODUCT: UNLEADED PRODUCT CODE 2 HIGH WATER LIMIT 1.0 OVERFILL LIMIT: 10861 HIGH PRODUCT LIMIT: 11464 LOW PRODUCT: 2973 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 3 THERMAL COEFF: 0.000700 DELIVERY DELAY: 5 TANK FULL CAPACITY: 12068 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 119.75 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I62A00 DEC 21, 2023 10:44 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 3010 2 UNLEADED 0 3 0 4 0 +AAMAAQ- I63600 DEC 21, 2023 10:44 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 UNLEADED 1810 3 0 4 0 +AAMAAQ- I61100 DEC 21, 2023 10:44 AM LEAK TEST METHOD - - - - - - - - - - - - TEST CSLD : ALL TANK Pd +AD0- 95+ACU- CLIMATE FACTOR:MODERATE REPORT ONLY: DISABLED TST EARLY STOP:DISABLED +AAMAAQ- I70300 DEC 21, 2023 10:44 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DIESEL SUMP TRI-STATE (SINGLE FLOAT) 2 UNLEADED SUMP TRI-STATE (SINGLE FLOAT) 3 UNL DISP SUMP TRI-STATE (SINGLE FLOAT) 4 DSL 2 HELPER SUMP TRI-STATE (SINGLE FLOAT) 5 DSL 2 DISP SUMP TRI-STATE (SINGLE FLOAT) 6 DSL 3 DISP SUMP TRI-STATE (SINGLE FLOAT) 7 DSL 3 HELPER SUMP TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) +AAMAAQ- I80800 DEC 21, 2023 10:44 AM RELAY SETUP REPORT R 1:LOW LEVEL OR LEAK TYPE: STANDARD NORMALLY OPEN IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:LOW PRODUCT ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:LIQUID WARNING R 2: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - +AAMAAQ- I10200 DEC 21, 2023 10:44 AM 144494 PENSKE 2211 SO. 2000 W. S.L.C. UT. 84119 801-972-9544 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163655 162552 2 INTERSTITIAL BD 201596 200458 3 UNUSED 5133949 5089369 4 UNUSED 5114211 5067394 5 UNUSED 5120962 5071669 6 UNUSED 5105446 5072700 7 UNUSED 5117104 5059060 8 UNUSED 5111104 5066943 9 RELAY BOARD 14979 14942 10 UNUSED 5112897 5065838 11 UNUSED 5120591 5056086 12 UNUSED 5103253 5063733 13 UNUSED 5107690 5072476 14 UNUSED 5098925 5063733 15 UNUSED 5105932 5073765 16 UNUSED 5106339 5065151 COMM 1 UNUSED 5113969 5073185 COMM 2 SERIAL SAT BD 479050 476351 COMM 3 PRINTER BOARD 9983 9956 COMM 4 UNUSED 5114762 5053895 COMM 5 UNUSED 5116669 5067987 COMM 6 UNUSED 5100660 5065366 +AAM- W.O.# NW1-2363775 OVF