HomeMy WebLinkAboutDAQ-2025-002273
1
DAQC-404-25
Site ID 10008 (B5)
MEMORANDUM
TO: FILE – NUCOR STEEL
THROUGH: Harold Burge, Major Source Compliance Section Manager
FROM: Rob Leishman, Environmental Scientist
DATE: April 28, 2025
SUBJECT: Nucor Bar Mill Group – Plymouth Division, NSPS, Title V, Box Elder County,
FRS # UT00000049000300002
INSPECTION TYPE: State Electronic Data Report (SEDR) Review
REVIEW DATE: April 28, 2025
SOURCE LOCATION: Plymouth/Box Elder County
SOURCE CONTACT: Kyndal Bair 435-458-2496
APPLICABLE
REGULATIONS: Title V Operating Permit
Permit Number: 300002004
Date of Permit: May 23, 2022
Date of Last Revision: September 12, 2024
SOURCE REVIEW EVALUATION:
SOURCE INSPECTION
EVALUATION: With the exception of sources that only monitor for opacity, quarterly
report memoranda will only address the findings of the quarterly report.
Approval Order and Title V permit conditions addressing continuous
emission monitoring requirements will be addressed in Nucor Steel’s
relative accuracy performance specification test review memorandum.
SEDR Review:
First Quarter 2025
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During
Point Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
Baghouse
Stack 1888 CO 100% 02/14/25 09/06/24 Baghouse
Stack CO 0.00 1200 lbs/hr -
1 hr average
1 8 2
2
First Quarter 2025
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During
Point Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
Baghouse
Stack 1888 NOx 100% 02/14/25 09/06/24 Baghouse
Stack CO 0.00 682.93 lb/hr -
8 hr average
Baghouse
Stack 1888 SO2 100% 02/14/25 09/06/24 Baghouse
Stack CO 0.00
2800 tons/yr
- rolling 12-
month total
Baghouse
Stack NOx 0.00
245 tons/yr -
rolling 12-
month total
Baghouse
Stack NOx 0.00
59.5 lb/hr -
calendar-day
average
(State Only)
Baghouse
Stack SO2 0.00
93.98 lb/hr -
3 hr rolling
average
Baghouse
Stack SO2 0.00 89 lb/hr - 24
hr average
Baghouse
Stack SO2 0.00
245 tons/yr -
rolling 12-
month total
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
Baghouse
Stack CO 0 0 0 0 0 1200 lbs/hr - 1 hr average
Baghouse
Stack CO 0 0 0 0 0 682.93 lb/hr - 8 hr average
Baghouse
Stack CO 0 0 0 0 0 2800 tons/yr - rolling 12-
month total
Baghouse
Stack NOx 0 0 0 0 0 245 tons/yr - rolling 12-
month total
Baghouse
Stack NOx 0 0 0 0 0 59.5 lb/hr - calendar-day
average (State Only)
Baghouse
Stack SO2 0 0 0 0 0 93.98 lb/hr - 3 hr rolling
average
Baghouse
Stack SO2 0 0 0 0 0 89 lb/hr - 24 hr average
Baghouse
Stack SO2 0 0 0 0 0 245 tons/yr - rolling 12-
month total
3
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
Baghouse Stack CO 0 0 0 0 0
Baghouse Stack NOx 0 0 0 0 0
Baghouse Stack SO2 0 0 0 0 0
Pollutant Concentration
Exceeded Span of CEM
Monitor Outage During
Point Source Operation
Alternate
Sampling CEM Modifications
0 Hours 0 Hours 0 Hours 0 Events
SOURCE INSPECTION
SUMMARY EVALUATION: Nucor Steel maintains its CEMS as required in R307-170 and 40 CFR
60.13.
CURRENT
RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related
problems that do not warrant issuing a violation. Nucor Steel was in
compliance during this reporting period. No further enforcement actions
should be taken. Nucor Steel’s NSPS monitoring system meets the
performance standards of 40 CFR 60, Appendix B Performance
Specifications. Duplicate monitoring systems and offset calibration times
have resulted in monitor unavailability at or near zero hours.
HPV: No
RECOMMENDATION
FOR NEXT INSPECTION: Check DAS for daily zero and span drift.
Check the QC program to ensure that monitor drift is being tracked and
that the source can identify excessive drift.
ATTACHMENTS: Spreadsheet Review.
Nucor Steel EER 1Q2025
Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No
1 Type Code 100
(Company Information)Type Code Company Manager Company Name AIRS # Phone Number
Environmental
Contact
1 100 Adam Zewe 00300002 435-458-2415 Doug Jones
1 100 0 0 0 0
1 Type Code 110
(Point Source Identification)Type Code Point Source
Quarter
1 - 4 Year
Point Source
Operating Hrs. in
Quarter
1 110 1 2025 1888
1 110 0 0 0
1 110 0 0 0
1 Type Code 200
(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date
Monitor
Location
1 200 CO Ecochem MC3 512 0 1000 3/20/2013 STACK
1 200 NOx Ecochem MC3 512 0 250 3/20/2013 STACK
1 200 SO2 Ecochem MC3 512 0 50 3/20/2013 STACK
1 200 CO Thermo Scientific 48iQ-CAN 1181830035 0 1000 12/14/2018 STACK
1 200 NOx Thermo Scientific 42iQLS-ACBNA 1181830033 0 250 12/14/2018 STACK
1 200 SO2 Thermo Scientific 43iQ-CAN 1181830034 0 50 12/14/2018 STACK
1 200 0 0 0 0 0 0 1/0/1900 0
1 200 0 0 0 0 0 0 1/0/1900 0
1
Type Code310
(Excess Emissions)
SUMMARY REPORT
Type Code Channel
Total Hours of Excess
Emissions
Excess Emissions -
% of Total
Operating Hours
RC 701 Hours -
start
up/Shutdown
RC 702 Hours-
Control Equipment
Problems
RC 703 Hours -
Process Problems
RC 704, 706, 707
Hours -Other Known
Causes
RC 705 Hours -
Unknown
Causes
Emission
Limitation
Emission
Limitation
Units
Emission
Limitation
Averaging
Period
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 1200 lbs/hr 1 hr average
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 682.93 lb/hr 8 hr average
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 2800 tons/yr rolling 12 month total
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 245 tons/yr rolling 12 month total
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 59.5 lb/hr calendar-day average (State Only)
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 93.98 lb/hr 3 hr rolling average
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 89 lb/hr 24 hr average
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 245 tons/yr rolling 12 month total
1 310 0 0 0 0 0 0 0 0 0
1 310 0 0 0 0 0 0 0 0 0
1 Type Code 300 (CMS
Performance Summary) Type Code Channel
Point Source Operating
Hours
Downtime - % of
Total Operating
Hours
Total CMS
Downtime
RC 721 Hours -
Monitor
Malfunction
RC 722 Hours -
Non-monitor
Malfunction
RC 723 Hours -
QA Calibrations
RC 724 Hours -
Other Known
Causes
RC 725
Hours -
Unknown
Causes
1 TRUE 300 CO 1888 0.00% 0 0 0 0 0 0
1 TRUE 300 NOx 1888 0.00% 0 0 0 0 0 0
1 TRUE 300 SO2 1888 0.00% 0 0 0 0 0 0
1 300 0 0 0 0 0 0
1 300 0 0 0 0 0 0
1
Type Code 250
(Performance Specification
RATA Results)
Type Code Channel
Date of Most Current
RATA
Date of Preceding
RATA
Months Between
RATA's
Units of
Measurement CEM Value Reference Method
Value
Relative
accuracy Pass/ Fail
1 396 Days 250 CO 09/06/24 08/07/23 13 lbs/hr 208.5 211.3 77.00% Pass
1 396 Days 250 NOx 09/06/24 08/07/23 13 lbs/hr 40.9 40.1 754.00% Pass
1 396 Days 250 SO2 09/06/24 08/07/23 13 lbs/hr 43.9 43.8 724.00% Pass
1 396 Days 250 CO 09/06/24 08/07/23 13 lbs/hr 231.1 211.3 208.00% Pass
1 396 Days 250 NOx 09/06/24 08/07/23 13 lbs/hr 35.8 35.2 540.00% Pass
1 396 Days 250 SO2 09/06/24 08/07/23 13 lbs/hr 44.3 44.3 795.00% Pass
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
Point Source
Point Source
Point Source
Baghouse Stack
0
0
0
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
0
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
Nucor Steel
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
0
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
0
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Nucor Steel EER 1Q2025
1 Type Code 260
(CGA Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 260 CO 02/14/25 1 EB0142277 02/08/27 P1 ppm 243.1 249 590.00% pass low
1 Valid Cal. Gas 260 CO 02/14/25 2 EB0085547 05/17/26 P1 ppm 544.567 544.3 26.70% pass high
1 Valid Cal. Gas 260 NOx 02/14/25 1 EB0142277 02/08/27 P1 ppm 64.7 63.8 90.00% pass low
1 Valid Cal. Gas 260 NOx 02/14/25 2 EB0085547 05/17/26 P1 ppm 140.467 136.5 396.70% pass high
1 Valid Cal. Gas 260 SO2 02/14/25 1 EB0142277 02/08/27 P1 ppm 13.5 12.7 80.00% pass low
1 Valid Cal. Gas 260 SO2 02/14/25 2 EB0085547 05/17/26 P1 ppm 26.933 27.8 86.70% pass high
1 Valid Cal. Gas 260 CO 02/14/25 1 EB0142277 02/08/27 P1 ppm 241.467 249 753.30% pass low
1 Valid Cal. Gas 260 CO 02/14/25 2 EB0085547 05/17/26 P1 ppm 531.733 544.3 1256.70% pass high
1 Valid Cal. Gas 260 NOx 02/14/25 1 EB0142277 02/08/27 P1 ppm 65.633 63.8 183.30% pass low
1 Valid Cal. Gas 260 NOx 02/14/25 2 EB0085547 05/17/26 P1 ppm 138.5 136.5 200.00% pass high
1 Valid Cal. Gas 260 SO2 02/14/25 1 EB0142277 02/08/27 P1 ppm 12.8 12.7 10.00% pass low
1 Valid Cal. Gas 260 SO2 02/14/25 2 EB0085547 05/17/26 P1 ppm 25.167 27.8 263.30% pass high
1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 Type Code 270
(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code Channel Start Date Start Time End Date End Time Hours
1 0 210 0 1/0/00 0:00 1/0/00 0:00
1
1 None Reported
1 0 TC 220 Hours 0.00 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00
1 0.00 TC 300 Hours 0.00 TRUE
None Reported None Reported None Reported None Reported None Reported None Reported
Point Source
Point Source
Point Source
None Reported
Baghouse Stack
Baghouse Stack
Baghouse Stack
0
Baghouse Stack
Baghouse Stack
Type Code 550
(Changes in Operation in
Control Equipment When
CEM Data Not Available)
Type Code 500
(Boiler Operating Days
w/o 18 Hours of Data)
Type Code 450
(Data Excluded)
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code 220
(Monitor Outage
During Point Source Operation)
Type Code 230
(Manual Sample - Alternate
Sampling During Monitor
Outage)
Type Code 240
(CEM Modifications)
Type Code 530
(Excess Emissions During
Emergency Conditions)
Baghouse Stack
Baghouse Stack
0
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
Baghouse Stack
0
0
0
Nucor Steel EER 1Q2025
Relative Accuracy Overview
Point Source Channel
Date of Most
Current
RATA
Date of
Preceding
RATA
Months Between
RATA's
Units
Measured CEM Value Reference Method
Value
Relative
Accuracy Pass/ Fail
Baghouse Stack CO 09/06/24 08/07/23 13 lbs/hr 208.5 211.30 77.00% Pass
Baghouse Stack NOx 09/06/24 08/07/23 13 lbs/hr 40.9 40.10 754.00% Pass
Baghouse Stack SO2 09/06/24 08/07/23 13 lbs/hr 43.9 43.80 724.00% Pass
Baghouse Stack CO 09/06/24 08/07/23 13 lbs/hr 231.1 211.30 208.00% Pass
Baghouse Stack NOx 09/06/24 08/07/23 13 lbs/hr 35.8 35.20 540.00% Pass
Baghouse Stack SO2 09/06/24 08/07/23 13 lbs/hr 44.3 44.30 795.00% Pass
*
NSPS CGA First 2025
Audit Gas Ranges Audit Gas Ranges
AP1 Low AP2 Low AP1 High AP2 High
Baghouse Stack CO 2/14/25 1000 249 200 to 300
Baghouse Stack CO 2/14/25 1000 544.3 500 to 600
Baghouse Stack NOx 2/14/25 250 63.8 50 to 75
Baghouse Stack NOx 2/14/25 250 136.5 125 to 150
Baghouse Stack SO2 2/14/25 50 12.7 10 to 15
Baghouse Stack SO2 2/14/25 50 27.8 25 to 30
Baghouse Stack CO 2/14/25 1000 249 200 to 300
Baghouse Stack CO 2/14/25 1000 544.3 500 to 600
Baghouse Stack NOx 2/14/25 250 63.8 50 to 75
Baghouse Stack NOx 2/14/25 250 136.5 125 to 150
Baghouse Stack SO2 2/14/25 50 12.7 10 to 15
Baghouse Stack SO2 2/14/25 50 27.8 25 to 30
Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used
Nucor Steel EER 1Q2025
Monitoring Information TC 210, 230, & 240
Type Code 210
(Pollutant Concentration Exceeded Span of CEM) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 230
(Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 240
(CEM Modifications) - 100 (All)
*
Count of Channel Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
Grand Total
Nucor Steel EER 1Q2025
Type Code 220
(Monitor Outage During Point Source Operation) - 600 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
0 0
Grand Total 0 0
Nucor Steel EER 1Q2025
SO2 *
SO2 Type Code 410 (SO2) - 6000 (All)
SO2 *
SO2 Count of Magnitude of Emissions Column Labels
SO2 Row Labels Grand Total
SO2 Grand Total
NOx *
NOx Type Code 420 (NOx) - 6000 (All)
NOx *
NOx Count of Magnitude of Emissions Column Labels
NOx Row Labels Grand Total
NOx Grand Total
NOx d *
NOx d Type Code 421 (Daily NOx Emissions) - 500 (All)
NOx d *
NOx d Count of Reason Code Column Labels
NOx d Row Labels Grand Total
NOx d Grand Total
CO *
CO Type Code 440
(CO) - 6000 (All)
CO *
CO Count of Magnitude of Emissions Column Labels
CO Row Labels Grand Total
CO Grand Total
Nucor Steel EER 1Q2025
Type Code 500
Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of
Data) After February 28, 2005 (90% Operating Hours For each 30 BOD)
- 500
(All)
*
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 510
(F-factor, Equations & Conversion Factors) - 500 (All)
Count of F-factor Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 520
(Minimum Data Not
Obtained <22/30 BODs) - 500
(All)
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 530
(Excess Emissions During Emergency Conditions) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 540
(Fuel Pre-treatment Credit SO2) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
TypeCode 550
(Changes in Operation in Control Equipment When CEM Data Not
Available) - 500
(All)
Column Labels
Row Labels Grand Total
Grand Total