Site 10972 (B1)
Jeffery Cowlishaw
Staker Parson Companies
89 West 13490 South, Suite 100
Draper, UT 84020-7209
Dear Mr. Cowlishaw:
Re: Staker Parson Materials and Construction – Temporary Relocation/Operation, Notice of
Intent – Weber County
Your Notice of Intent dated April 11, 2025, to relocate portable aggregate equipment to the
temporary material recycling project for Staker Parson Companies’ Hot Mix Asphalt facility,
located at 2350 South 1900 West, Ogden, Utah, was received by the Utah Division of Air Quality
(DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
Goodfellow Astec track crusher with 440 hp diesel engine
This equipment has been permitted for operation in the State of Utah by the Goodfellow
Corporation portable source Approval Order (AO) DAQE-AN140680003-18 dated April 18,
2018. This equipment will be operated by Staker Parson Companies which will be responsible for
all operating conditions and emission requirements for this temporary project. Approval is granted
to relocate and operate this equipment at the new location for a period not to exceed 180
operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of
equipment at this temporary site may be for up to 180 working days in any calendar year not to
exceed 365 consecutive days, starting from the initial relocation date. The operational days per
site cannot be extended beyond the stipulated 365 consecutive day period. Approval is subject to
the conditions of the dust control plan submitted for this location and the above portable AO. The
equipment opacity limits shall be operated within the limits Conditions II.B.1.c.A and II.B.1.c.F
of this site’s permanent AO AN109720009-15, dated October 22, 2015. Hours of operation shall
be held to 16 hours each day. The maximum production rate shall be held to the requested 500
tons per hour.
- / & ) Û Ý Û Ù Û Þ
DAQC-391-25
Page 2
Emissions for this project have been estimated at the following:
Pollutant gram/sec lbs/hr lbs/24 hr tons/yr
PM10 1.97 15.67 156.71 12.22
SOx 0.78 6.16 61.56 4.80
NOx 5.15 40.91 409.11 31.91
CO 1.36 10.75 107.54 8.39
VOC 0.21 1.68 16.83 1.31
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: Weber-Morgan Health Department
4 * - - $ . — + - A B v A ? A D @ @ w @ E ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Fri, Apr 11, 2025 at 2:57 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Staker Parson Companies has requested a Temporary Relocation. Please see the information below. Any
attachments can be access by clicking on the links.
Recipient Data:
Time Finished: 2025-04-11 14:57:31 MDT
IP: 165.225.10.103
ResponseID: R_3Suz25V9eYfjIEk
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/m_LJTpMsGPmKe_
PFP2U4GdPYkhfLLpLgIFXLsTtjHWLmBnzBPgIauDK6pZV2NGophKjw_7EZc_l9teRCSiHRvR8zP8yAeL3TjyqH0mVE
KsoUSB7k6SFVfZRrCEPnsyVPDBrHxMYofBQ7j_1eZr_C2sIsZjMuPkDP9u3yln91gur_h6P4ucgU_
61wLlbCRrDtWqwZxJMiPedfuXdTM9MOlF8YpUacDcaaWf1K8LNWnM4fwMHvFDwilNd4BNMg2i1X3QjDdYfIgkUui_
oGmpaG1dgIXiTzQXn73d0Ib701CMongit6QrK1gyhmxnHNbHLzu8zcWAupiArWFQaJ4GBeuA
Response Summary:
Please fill out the information below:
Contact Person: Jeffery Cowlishaw
Company Name: Staker Parson Companies
Mailing Address: 2350 S 1900 W
City: Ogden
Zip: 84401
Phone Number: 385-405-4315
Email: jeffery.cowlishaw@stakerparson.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
Yes
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
E1C29E24EB
Briefly give directions to the site and/or physical address:
2350 S 1900 W Ogden UT 84401
Proposed Relocation Information:
Closest City Ogden
County Weber
UTM X Coordinates 4,564,347.690
UTM Y Coordinates 414,470.127
Approximate distance to the nearest house/business 185 yards
UTM X Coordinates to nearest house/business 4,564,511.738
UTM Y Coordinates to nearest house/business 414,493.847
Does this site currently have a permit with DAQ?
Yes
4/12/25, 9:49 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1829141279933204042%7Cmsg-f:1829141279933204042&s…1/2
If yes, what is the Permit (DAQ-AN) # ?
DAQE-AN109720009-15
If yes, what is the Permit Holder's Name?
Staker Parson Companies
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
Goodfellows
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type track crusher
Make/Model Astec/ 4250
Design Capacity 500 TPH/ 440 HP
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_Zq0nUiHQQwdTfKp
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6AM
Ending time of operation (am/pm) 10PM
Maximum hourly production rate for project 500 TPH
Expected startup date 04/16/2025
Expected completion date 08/11/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2zUglqmsayoKEUe
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2AZo1cFdDh7aq9b
4/12/25, 9:49 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1829141279933204042%7Cmsg-f:1829141279933204042&s…2/2