Loading...
HomeMy WebLinkAboutDAQ-2025-002254 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. 800 346-3128 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Tim Davis Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-386-25 Site 12188 (B1) Christopher Rose Staker Parson dba Western Rock Products 89 West 13490 South, Suite 100 Draper, Utah 84020-7209 Dear Mr. Rose: Re: Staker Parson dba Western Rock Products – Temporary Relocation/Operation, Notice of Intent – Washington County Your Notice of Intent dated April 17, 2025, to relocate portable aggregate equipment to the temporary project for Western Rock Products' Fort Pierce Pit, located two miles east of the Bloomington exit, near St. George, Utah, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: II.A.126 120 TPH impact crusher II.A.708 850 kW generator The State of Utah has permitted portable equipment for Staker Parson Companies on the Approval Order DAQE-AN115180014-15 dated July 6, 2015. The above location is a permitted aggregate facility with established production limits. All equipment operating at this site must be in accordance with the current Approval Order (AO) for this site DAQE-AN121880006-24 dated December 11, 2024. The production of aggregate and hours of operation from all temporary projects when combined with the permanent equipment’s production and hours of operation cannot exceed the 12-month rolling limits as per Conditions II.B.2.a.A and II.B.2.a.B of this AO. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. - / & ) Û Ý Û Ù Û Þ DAQC-386-25 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SW:rh Enclosure: Submitted Temporary Relocation Form cc: Southwest Utah Public Health Department 4 * - - $ . — + - A A v A ? A D @ E w A F ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Thu, Apr 17, 2025 at 10:54 AM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Staker Parson d.b.a. Western Rock Products has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2025-04-17 10:54:04 MDT IP: 165.225.10.115 ResponseID: R_1qankBhL8rJNjdU Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ D6McJdgXtsM7lHqbbQpCy-SlCCyQkqc7PYFR9t8UyrniDXNE4I8vyg-KI3ktQXi2MQd3lQ_f4xy_lTH5sIfpOnok_ t8uwgNGfXEULmayk2gIB5z7_lbZ8cXrGCgFUHrwCi39O8hWTL5tSd-oq0ks5Mwy3S-D37wgpyz7PcZslIp2jtzlh0bOFYUiC SZ9Q7X1D3Utsnh7mniJmef7X4tub0Rf0iKdgtAq-JsGfPIgMFVhQBpmvCaOPWdUNv0Cpf8 GOLw1VFjDUWtdNxHfwDEiTmKdj--IEvZ43227WErFhpLb5Udvg4SXhwrhoL8ZEOY-wOLS5glCXe45ICDFSH3GMg Response Summary: Please fill out the information below: Contact Person: Christopher Rose Company Name: Staker Parson d.b.a. Western Rock Products Mailing Address: 89 W 13490 S City: Draper Zip: 84020 Phone Number: 3854002119 Email: chris.rose@stakerparson.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... FEDFCBFD34 Briefly give directions to the site and/or physical address: 1834 E 4150 S, St. George, UT 84790 Proposed Relocation Information: Closest City St. George County Washington UTM X Coordinates 273859.98 m E UTM Y Coordinates 4101767.03 m N Approximate distance to the nearest house/business 1170 ft. UTM X Coordinates to nearest house/business 273523.80 m E UTM Y Coordinates to nearest house/business 4101900.89 m N Does this site currently have a permit with DAQ? Yes 4/21/25, 6:55 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1829669544159326921%7Cmsg-f:1829669544159326921&s…1/2 If yes, what is the Permit (DAQ-AN) # ? DAQE-AN121880006-24 If yes, what is the Permit Holder's Name? Staker Parson Companies Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-115180004-15 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Impact Crusher Serial or ID# II.A.126 Manufactured Date After 1984 Design Capacity 120 TPH 2 Equipment Type Generator Serial or ID# II.A.703 Manufactured Date After 1950 Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2cCRfeYJi5cTwTq Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 16 Starting time of operation (am/pm) 6 AM Ending time of operation (am/pm) 10 PM Maximum hourly production rate for project 400 Expected startup date 04/30/2025 Expected completion date 04/01/2026 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_6hsilHUs35bIqA1 Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3JknBnz6deyeOuF 4/21/25, 6:55 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1829669544159326921%7Cmsg-f:1829669544159326921&s…2/2