Loading...
HomeMy WebLinkAboutDERR-2025-003383Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 4/15/2025 Tanknology WO#NW1-2382638 Test Purpose COMPLIANCE Customer PO# Customer Location 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 7-ELEVEN 38707 1820 S Bangerter Hwy State ID 4002579 Salt Lake City, UT 84104 Attn: ENVIRONMENTAL DEPARTMENT Attn: (972) 828-7575 (801) 541-9345 Test / Inspection Description Item Tested Date Tested Result RP 1200 Overfill See test report for details 4/15/2025 Pass Overfill Insp OPW Flapper Valve TNK 1 RUL 4/15/2025 Pass Overfill Insp OPW Flapper Valve TNK 2 PUL 4/15/2025 Pass Overfill Insp OPW Flapper Valve TNK3 Diesel 4/15/2025 Pass Overfill Insp OPW Flapper Valve TNK4 TRK Diesel 4/15/2025 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) 7-ELEVEN 38707 1820 S Bangerter Hwy State ID 4002579 Salt Lake City, UT 84104 38707 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 800-800-4633 04/15/2025 RUL 1 19782 118.375 OPW PUL 2 7901 118.375 OPW DSL 3 11904 118.375 OPW DSL 4 19782 118.375 OPW UT151 David Mathie P.O. BOX 711 DALLAS, TX 75221 Overfill Prevention Equipment Inspection OPW 61 and 71 Series Overfill Prevention Device Inspection Date:4/15/2025 Customer Name:7-ELEVEN, INC. Location #:7-ELEVEN 38707 Location Address:1820 S Bangerter Hwy State ID 4002579 ,Salt Lake City ,UT , 84104 OPW Model Number:71S0 PART 1) Proper height setting calculation Maximum Tank Volume per: Tank Chart A gallons Max shut off requirement for Flapper is 95% B 95% Multiply Maximum tank volume by 95% C gallons Use tank chart to determine height of calculated volume D inches Measure top of fill riser threads, or face seal adapter when used, to tank top E inches Tank diameter From Chart F inches Upper Tube in tank (G) F - D = G G inches Subtract 2 inches from upper tube in tank G - 2"= H H inches Calculated minimum upper tube length (I) H + E = I I inches Actual measured upper tube length (Without fill adapter) (J) J inches PART 2) Device certification criteria evaluation Criteria 1 Does the overfill prevention device meet the 95% requirement? Criteria 1a If the final shutoff volume is installed greater than 95%, is there at least 250 gallons of ullage above the overfill device activation point to ensure that none of the tank top fittings are exposed to product, meeting the criteria established in EPA 280.20iic and per OPW installation guidelines. Criteria 2 Is the Actual measured upper tube length 6.5 inches or more than the fill riser? (J must be 6.5" or more than E) Criteria 3 Does the overfill prevention device function as required? (Inspect the device for damage, contamination, freedom of movement, weakening due to wear and corrosion) PART 3) Device Certification PASS / FAIL Technician certifies that the device is operationally compliant. TNK 1 19782.000 0.95 18792.900 106.375 55.875 118.375 12.000 10.000 65.875 66.875 Yes NA Yes Yes Pass TNK 2 7901.000 0.95 7505.950 106.875 59.500 118.375 11.500 9.500 69.000 70.875 Yes NA Yes Yes Pass TNK3 11904.000 0.95 11308.800 105.875 52.000 118.375 12.500 10.500 62.500 63.375 Yes NA Yes Yes Pass TNK4 TRK 19782.000 0.95 18792.900 106.375 69.500 118.375 12.000 10.000 79.500 80.375 Yes NA Yes Yes Pass Comments: Signature of Technician: Date: 4/15/2025 David Mathie WO: NW1- 2382638 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2382638 Site ID / Name:38707 / 7-ELEVEN 38707 Address:1820 S Bangerter Hwy State ID 4002579 City:Salt Lake City State:UT Zip:84104