Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-005606
DISPENSER SUMP TEST STP SUMP TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 3/30/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 2/28/2024 Order Number: 2364512 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 47158/9427 3731 W. JORDAN LANDING State ID 4002232 WEST JORDAN, UT 84084 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting PEI/RP1200-12 pei.org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est Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 7/11/Speedway 47158/9427 3731 W. Jordan Landing West Jordan, UT 02/28/2024 Reg FRP 4 4 62" 19" 23" 0min 23" 60min 1hr 0" 4 Prm FRP 4 4 59" 20" 24" 0min 24" 60min 1hr 0" 4 Dsl FRP 4 4 62" 19" 24" 0min 24" 60min 1hr 0" 4 Disp 1,2 FRP 4 4 30" 4" 8" 0min 8" 60min 1hr 0" 4 3,4 FRP 4 4 30" 4" 8" 0min 8" 60min 1hr 0" 4 5,6 FRP 4 4 30" 4" 8" 0min 8" 60min 1hr 0" 4 Dominic Salas UT-378 PEI/RP1200-12 pei.org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est Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Speedway 47158/9427 02/28/2024 Disp 7,8 FRP 4 4 30" 4" 9" 0min 9" 60min 1hr 0" 4 9,10 FRP 4 4 30" 4" 8" 0min 8" 60min 1hr 0" 4 Dominic Salas UT-378