Loading...
HomeMy WebLinkAboutDERR-2025-003193Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 1/23/2025 Tanknology WO#NW1-2377661 Test Purpose COMPLIANCE Customer PO# Customer Location LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 LOVES COUNTRY STORE #686 20 South 1550 West St Brigham City, UT 84302 Attn: Reva Fittro Attn: MANAGER (405) 302-6794 (435) 723-1789 Test / Inspection Description Item Tested Date Tested Result Precision Line Tightness (.1 GPH) Tank BIO DSL Line 1 Biodiesel 1/23/2025 Pass PEI RP 1200 Leak Detector See test report for details 1/23/2025 Pass Impact Valve Inspection See test report for details 1/23/2025 Pass RP 1200 ATG See test report for details 1/23/2025 Pass RP 1200 Sensors See test report for details 1/23/2025 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) Product Line Tightness Test Page 1 of 1 Work Order: 2377661 Date: 1/23/2025 Site Name/ID: LOVES COUNTRY STORE #686 / 686 Address: 20 South 1550 West St City: Brigham City State: UT Zip: 84302 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 6 Line # 1 TLD-1 BIO DSL Biodiesel Pressure 19:36 20:06 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com LOVES COUNTRY STORE #686 20 South 1550 West St Brigham City UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210OKLAHOMA CITYOK 73120 405-302-6794 01/23/2025 REGULAR REGULAR Low Sulfur Diesel Low Sulfur Diesel Biodiesel INCON TS-LLDINCON TS-LLDINCON TS-LLDINCON TS-LLDINCON TS-LLDINCON TS-LLD 37 2 38 2 2 38 40 2 39 2 30 2 UT151 David Mathie NW1-2377661 PREMIUM TRUL1:1 TRUL1:2 TPUL:1 TDSL:1 TDSL2:1 TBIO DSL:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2377661 Date:1/23/2025 Site Name/ID:LOVES COUNTRY STORE #686 Address:20 South 1550 West St City:Brigham City State:UT Zip:84302 How Inspected: Line Test NFPA 30A PEI RP1200 Other STP PRESSURE Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 40 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 40 Pass Fail Not Tested 13/14 85 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:2377661 Date:1/23/2025 Site Name/ID:LOVES COUNTRY STORE #686 Address:20 South 1550 West St City:Brigham City State:UT Zip:84302 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 85 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested 17/18S/ 40 Pass Fail Not Tested 17S/ 40 Pass Fail Not Tested 18/19S/ 40 Pass Fail Not Tested 19/20S/ 40 Pass Fail Not Tested 20/21S/ 40 Pass Fail Not Tested 21/22S/ 40 Pass Fail Not Tested 22/23S/ 40 Pass Fail Not Tested 23/24S/ 40 Pass Fail Not Tested 24/25S/ 40 Pass Fail Not Tested 25/ 40 Pass Fail Not Tested 26/27 40 Pass Fail Not Tested 26/27 85 Pass Fail Not Tested 26/27 91 Pass Fail Not Tested BIO DSL TEST PORT/ 40 Pass Fail Not Tested NA Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com LOVES COUNTRY STORE #686 LOVE'S COUNTRY STORE 20 South 1550 West St Brigham City UT 84302 0100698 Tanknology, Inc. 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITYOK 73120 405-302-6794 800-964-1250 01/23/2025 1 2 3 4 RUL RUL PREM DSL1 TS550 INCON TS550 INCON TS550 INCON TS550 INCON 19942 11624 7852 29780 120 120 120 120 UT151 David Mathie LOVES COUNTRY STORE #686 LOVE'S COUNTRY STORE 20 South 1550 West St Brigham City UT 84302 0100698 Tanknology, Inc. 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITYOK 73120 405-302-6794 800-964-1250 01/23/2025 5 6 DSL2 BIO DSL TS550 INCON TS550 INCON 29780 19942 120 120 UT151 David Mathie 20 South 1550 West St LOVES COUNTRY STORE #686 20 South 1550 West St, Brigham City, UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 405-302-6794 01/23/2025 ANNULAR ANNULAR ANNULAR ANNULAR ANNULAR STP SUMP RUL RUL/PREM DSL1 DSL2 BIO RUL RUL2SYPH UT151 David Mathie 20 South 1550 West St LOVES COUNTRY STORE #686 20 South 1550 West St, Brigham City, UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 405-302-6794 01/23/2025 STP STP STP STP SUMP SUMP SUMP PREM DSL1 DSL2 BIO DSL HVALVE METER DSL1 METER2 UT151 David Mathie 20 South 1550 West St LOVES COUNTRY STORE #686 20 South 1550 West St, Brigham City, UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 405-302-6794 01/23/2025 UDC UDC UDC UDC UDC UDC UDC 1/2 3/4 5/6 7/8 9/10 11/12 13/14 UT151 David Mathie 20 South 1550 West St LOVES COUNTRY STORE #686 20 South 1550 West St, Brigham City, UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 405-302-6794 01/23/2025 UDC UDC UDC UDC UDC UDC UDC 15/16 17S 17 18 19 20 21 UT151 David Mathie 20 South 1550 West St LOVES COUNTRY STORE #686 20 South 1550 West St, Brigham City, UT 84302 686 Tanknology, Inc. LOVE'S COUNTRY STORE 10601 NORTH PENNSYLVANIA AVENUE P.O. BOX 26210 OKLAHOMA CITY, OK 73120 405-302-6794 01/23/2025 UDC UDC UDC UDC UDC 22 23 24 25 26/27 UT151 David Mathie Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2377661 Site ID / Name:686 / LOVES COUNTRY STORE #686 Address:20 South 1550 West St City:Brigham City State:UT Zip:84302 W.O.# NW1-2377661 OVF Loves Travel Stops #686 - User access level gal in °F | Personal Preferences Tank Status System FMS Setup Auto Refresh Status Alarms Control Compliance Reports 01/23/2025 22:25:11 Tanks Lines Sensors Pumps TANKS Image Manifold ID Tank ID Name Product Alarms Level Gross Volume Net Volume Ullage Water Level Temperature Max Capacity Capacity % 1 1 Unleaded 1 Regular Unleaded 81.33 14,573.04 14,796.05 3,369.50 0.30 38.11 19,942.00 73.08 1 2 Unleaded 2 Regular Unleaded 82.22 8,840.43 8,969.20 1,620.67 0.04 39.17 11,624.00 76.05 3 Premium Premium Unleaded 48.94 3,058.67 3,085.05 4,008.13 0.00 46.09 7,852.00 38.95 2 4 Diesel 1 Diesel 69.81 18,801.80 19,039.00 7,999.67 0.02 41.97 29,780.00 63.14 2 5 Diesel 2 Diesel 71.92 19,454.22 19,673.23 7,346.86 0.03 43.92 29,780.00 65.33 6 BIO BIO 18.82 1,973.44 1,979.23 15,968.98 0.30 55.48 19,942.00 9.90 7 DEF DEF 73.03 12,880.13 12,857.19 5,067.67 0.00 62.74 19,942.00 64.59 8 OWS OWS 66.72 4,464.81 4,480.49 0.00 0.00 52.26 3,760.12 118.74 MANIFOLDS Manifold ID Name Product Alarms Gross Volume Net Volume Max Capacity Capacity % 1 Unleaded Regular Unleaded 23,413.59 23,765.39 31,566.00 74.17 2 Diesel Diesel 38,256.02 38,712.23 59,560.00 64.23 Copyright © 2004-2016 Franklin Fueling Systems. All rights reserved. 2.10.0.8346 FFS TS-550 evo - Tank Status http://10.6.86.50/21008346/tank_status.html 1 of 1 1/23/2025, 10:24 PM Loves Travel Stops #686 - User access level Personal Preferences FMS Alarms System FMS Setup Status Alarms Control Compliance Reports 01/23/2025 22:38:30 Device Description Type Date Occurred BIO Low product volume Alarm 01/21/2025 13:11:53 Copyright © 2004-2016 Franklin Fueling Systems. All rights reserved. 2.10.0.8346 FFS TS-550 evo - FMS Alarms http://10.6.86.50/21008346/fms_alarms.html 1 of 1 1/23/2025, 10:37 PM Loves Travel Stops #686 - User access level °F | Personal Preferences Sensor Status System FMS Setup Auto Refresh Status Alarms Control Compliance Reports 01/23/2025 22:27:16 Tanks Lines Sensors Pumps 2 Wire Sensors Name Alarms Status Dispenser 1/2 UDC Sensor Ok Dispenser 3/4 UDC Sensor Ok Dispenser 5/6 UDC Sensor Ok Dispenser 7/8 UDC Sensor Ok Dispenser 9/10 UDC Sensor Ok Dispenser 11/12 UDC Sensor Ok Dispenser 13/14 UDC Sensor Ok Dispenser 15/16 UDC Sensor Ok Dispenser 17 Sat. UDC Sensor Ok Dispenser 17 UDC Sensor Ok Dispenser 18 UDC Sensor Ok Dispenser 19 UDC Sensor Ok DSispenser 20 UDC Sensor Ok Dispenser 21 UDC Sensor Ok Dispenser 22 UDC Sensor Ok Dispenser 23 UDC Sensor Ok Dispenser 24 UDC Sensor Ok Dispenser 25 UDC Sensor Ok Dispenser 26/27 UDC Sensor Ok 3 Wire Sensors Name Alarms Status Unleaded 1 Interstitial Sensor Ok UNL 2/ PUL Interstitial Sensor Ok Diesel 1 Interstitial Sensor Ok Diesel 2 Interstitial Sensor Ok BIO Interstitial Sensor Ok DEF Interstitial Sensor Ok H-Valve Sump Sensor Ok Unleaded 1 STP Sump Sensor Ok unld 2 sump Ok Premium STP Sump Sensor Ok Diesel 1 STP Sump Sensor Ok Diesel 2 STP Sump Sensor Ok BIO STP Sump Sensor Ok DEF STP Sump Sensor Ok Diesel 1 Meter L Sump Sensor Ok Diesel 2 Meter L Sump Sensor Ok Copyright © 2004-2016 Franklin Fueling Systems. All rights reserved. 2.10.0.8346 FFS TS-550 evo - Sensor Status http://10.6.86.50/21008346/sensor_status.html 1 of 1 1/23/2025, 10:26 PM Loves Travel Stops #686 - User access level Personal Preferences Setup System FMS Setup Expand Collapse Edit Download Upload Reset Configuration FAST Parameters Correction Table Group Name Parameter Name Parameter Value System Preferences Language English Date/Time Short date format MM/dd/yyyy Long date format EEEE, MMMM dd, yyyy Short time format HH:mm Long time format HH:mm:ss Numbers Digit grouping Enabled Digit grouping symbol , Decimal symbol . Display leading zeroes Yes Units Volume Gallons Length Inches Temperature Fahrenheit Flow Gallons/Hour FMS - Line Pressure Pounds per square inch VRM - Tank Ullage Pressure Inches of Water Density Kilograms per cubic meter Mass Kilograms System ID Site Name Loves Travel Stops #686 Web UI URL http://localhost/tsa ID Line 1 20 S. 1550 West St ID Line 2 Bringham City, UT ID Line 3 84302 ID Line 4 435-723-1789 ID Line 5 USA System Configuration Technical Support Key 0 Enable Log Files No Modules Expected IO 0 AC Input 1 Relay 1 Probe 1 2-Wire Sensor 2 3-Wire Sensor 2 4-20mA Input 1 Internal Printer 1 LON 0 DIM 0 Console DTU 0 Communications Serial Ports COMM 1 Mode Veeder-Root Baud Rate 9600 Data Bits 8 FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 1 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Parity None Stop Bits 1 COMM 2 Baud Rate 9600 Data Bits 8 Parity None Stop Bits 1 Response Timeout 8 RS-485 Baud Rate 9600 Data Bits 8 Parity None Stop Bits 1 Modem Type None Protocols Veeder-Root Port 10001 Veeder-Root Client Timeout 0 HyperPIB Enable over TCP/IP No E-Mail "From" Address your_from@address.com SMTP Host your_smtp_host_address SMTP Port 25 Enable Authentication No Maximum Queue Size 20 Retry Timeout 3600 Watchdog Timeout 30 Enable Debugging No System Sentinel AnyWare IP Address Port 80 Path /ssa/_data/ssa_webdata.dll Priority Highest Database Connection Database User Name SSAADMIN Database User Password ****** Site ID 0 Data Logging Mode Disabled AC Input Modules Module 1 Channels 7 Channel 1 Name Regular Unleaded 1 Hook Enabled Yes Active State High Action None Channel 2 Name Regular Unleaded 2 Hook Enabled Yes Active State High Action None Channel 3 Name Premium Hook Enabled Yes Active State High Action None Channel 4 Name Diesel 1 Hook FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 2 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Enabled Yes Active State High Action None Channel 5 Name Diesel 2 Hook Enabled Yes Active State High Action None Channel 6 Name Bio Hook Enabled Yes Active State High Action None Channel 7 Name DEF Hook Enabled Yes Active State High Action None Probe Modules Module 1 Channels 8 Channel 1 Name Regular Unleaded 1 Probe Type FMP-LL3 Channel 2 Name Regular Unleaded 2 Probe Type TS-LL2 Channel 3 Name Premium Unleaded Probe Type TS-LL2 Channel 4 Name Diesel 1 Probe Type TS-LL2 Channel 5 Name Diesel 2 Probe Type TS-LL2 Channel 6 Name BIO Probe Type FMP-LL3 Channel 7 Name DEF Probe Type TS-LL2 Channel 8 Name OWS Probe Type TS-LL2 2-Wire Sensor Modules Module 1 Channels 8 Channel 1 Name Dispenser 1/2 UDC Sensor Enabled Yes Monthly compliance No Channel 2 Name Dispenser 3/4 UDC Sensor Enabled Yes Monthly compliance No Channel 3 Name Dispenser 5/6 UDC Sensor Enabled Yes Monthly compliance No Channel 4 Name Dispenser 7/8 UDC Sensor Enabled Yes Monthly compliance No FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 3 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Channel 5 Name Dispenser 9/10 UDC Sensor Enabled Yes Monthly compliance No Channel 6 Name Dispenser 11/12 UDC Sensor Enabled Yes Monthly compliance No Channel 7 Name Dispenser 13/14 UDC Sensor Enabled Yes Monthly compliance No Channel 8 Name Dispenser 15/16 UDC Sensor Enabled Yes Monthly compliance No Module 2 Channels 11 Channel 1 Name Dispenser 17 Sat. UDC Sensor Enabled Yes Monthly compliance No Channel 2 Name Dispenser 17 UDC Sensor Enabled Yes Monthly compliance No Channel 3 Name Dispenser 18 UDC Sensor Enabled Yes Monthly compliance No Channel 4 Name Dispenser 19 UDC Sensor Enabled Yes Monthly compliance No Channel 5 Name DSispenser 20 UDC Sensor Enabled Yes Monthly compliance No Channel 6 Name Dispenser 21 UDC Sensor Enabled Yes Monthly compliance No Channel 7 Name Dispenser 22 UDC Sensor Enabled Yes Monthly compliance No Channel 8 Name Dispenser 23 UDC Sensor Enabled Yes Monthly compliance No Channel 9 Name Dispenser 24 UDC Sensor Enabled Yes Monthly compliance No Channel 10 Name Dispenser 25 UDC Sensor Enabled Yes Monthly compliance No Channel 11 Name Dispenser 26/27 UDC Sensor Enabled Yes Monthly compliance No 3-Wire Sensor Modules FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 4 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Module 1 Channels 8 Channel 1 Name Unleaded 1 Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 2 Name UNL 2/ PUL Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 3 Name Diesel 1 Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 4 Name Diesel 2 Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 5 Name BIO Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 6 Name DEF Interstitial Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 7 Name H-Valve Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 8 Name Unleaded 1 STP Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Module 2 Channels 8 Channel 1 Name unld 2 sump Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 2 Name Premium STP Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 3 Name Diesel 1 STP Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 4 Name Diesel 2 STP Sump Sensor FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 5 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 5 Name BIO STP Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 6 Name DEF STP Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 7 Name Diesel 1 Meter L Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No Channel 8 Name Diesel 2 Meter L Sump Sensor Enabled Yes Type Interstitial (EIS) OR 2-Wire Sensor Monthly compliance No 4-20mA Input Modules Module 1 Channels 6 Channel 1 Name Unleaded East Transducer Service Type Line Leak Detection Channel 2 Name Unleaded West Transducer Service Type Line Leak Detection Channel 3 Name Premium Unleaded Transducer Service Type Line Leak Detection Channel 4 Name Diesel 1 Transducer Service Type Line Leak Detection Channel 5 Name Diesel 2 Transducer Service Type Line Leak Detection Channel 6 Name BIO Transducer Service Type Line Leak Detection Power Supply Low Voltage Inputs Channel 1 Name LV Input 1 Enabled Yes Active State High Action None Channel 2 Name LV Input 2 Enabled Yes Active State High Action None TS-TPI Enable Interface Yes Controllers Number of controllers 7 Controller 1 Name Regular Unleaded 1 Controller Enabled Yes FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 6 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Type Smart I Address 1 Group 0 Tank 1 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Regular Unleaded 1 Hook Input 2 Type 4-20mA Input Module Channel Unleaded East Transducer Controller 2 Name Regular Unleaded 2 Controller Enabled Yes Type Smart I Address 2 Group 0 Tank 1 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Regular Unleaded 2 Hook Input 2 Type 4-20mA Input Module Channel Unleaded West Transducer Controller 3 Name Premium Unleaded Controller Enabled Yes Type Smart I Address 3 Group 0 Tank 3 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Premium Hook Input 2 Type 4-20mA Input Module Channel Premium Unleaded Transducer Controller 4 Name Diesel 1 Controller Enabled Yes Type 3 Phase Smart 208/380V Address 4 Group 0 Tank 4 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Diesel 1 Hook Input 2 Type 4-20mA Input Module Channel Diesel 1 Transducer Controller 5 Name Diesel 2 Controller FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 7 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Enabled Yes Type 3 Phase Smart 208/380V Address 5 Group 0 Tank 5 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Diesel 2 Hook Input 2 Type 4-20mA Input Module Channel Diesel 2 Transducer Controller 6 Name BIO Mag Enabled Yes Type Mag/Eco Address 6 Group 0 Tank 6 Height 5.00 in Number of inputs 2 Input 1 Type AC Input Module Channel Bio Hook Input 2 Type 4-20mA Input Module Channel BIO Transducer Controller 7 Name DEF Controller Enabled Yes Type Smart I Address 7 Group 0 Tank 7 Height 5.00 in Number of inputs 1 Input 1 Type AC Input Module Channel DEF Hook Groups Number of groups 0 Relays Channel 1 Name Overfill Enabled Yes Type Alarm Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 1 Input 1 Type Controller Module Channel 2 Name Relay 2 Enabled Yes Type Unknown Polarity Normal FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 8 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Logic OR Logic Physically Wired As Normally Open Number of inputs 0 Relay Modules Module 1 10 Amp No Channels 7 Channel 1 Name Relay 1 Enabled No Type Submersible Pump Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 0 Channel 2 Name Relay 2 Enabled Yes Type Submersible Pump Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 0 Channel 3 Name BIO Low Level Enabled Yes Type Alarm Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 1 Input 1 Type Controller Module Channel 4 Name Diesel 1 HI Level Enabled Yes Type Alarm Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 1 Input 1 Type Controller Module Channel 5 Name Diesel 2 HI Level Enabled Yes Type Solenoid Polarity Normal Logic OR Logic Physically Wired As Normally Open Number of inputs 1 Input 1 Type Controller Module Channel 6 Name Diesel 1 Hook Enabled Yes Type Submersible Pump FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 9 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Polarity Invert Logic OR Logic Physically Wired As Normally Open Number of inputs 0 Channel 7 Name Diesel 2 Hook Enabled Yes Type Submersible Pump Polarity Invert Logic OR Logic Physically Wired As Normally Open Number of inputs 0 Fuel Management System Ullage Percent 90 % Delivery Delay 15 min Correction Temperature 60.00 °F High Product Limit Level Static Tank Testing Region United States Monthly Leak Test Threshold 0.20 gph Yearly Leak Test Threshold 0.10 gph Sentinel Mode Threshold 3.00 gph Confidence 99% Minimum Leak Test Time 2 hr Maximum Leak Test Time 8 hr Alarm On Precision Leak Test Failure No Tanks Number of Tanks 8 Tank 1 Name Unleaded 1 Type Special 1 Manifolded Yes Manifold # 1 Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel Regular Unleaded 1 Probe Type FMP-LL3-125 Serial Number 7129508 Ratio 1 to 1 tip to head Float Type 4 in gas Water Float Yes Gradient 9.03000 µs/in Product Offset 0.00 in Water Offset -0.93 in Generator Mode Enable No Limits High High Product Level Limit 107.50 in High Product Level Limit 99.13 in High Water Level Limit 2.00 in Tank 2 Name Unleaded 2 Type Special 2 Manifolded Yes FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 10 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Manifold # 1 Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel Regular Unleaded 2 Probe Type Standard 125 Ratio 1 to 1 tip to head Float Type 4 in gas Water Float Yes Gradient 9.20419 µs/in Product Offset 0.00 in Water Offset -0.92 in Generator Mode Enable No Limits High High Product Level Limit 102.38 in High Product Level Limit 96.00 in High Water Level Limit 2.00 in Tank 3 Name Premium Type Special 3 Manifolded No Product # 2 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel Premium Unleaded Probe Type Standard 125 Ratio 1 to 1 tip to head Float Type 4 in gas Water Float Yes Gradient 9.20333 µs/in Product Offset 0.00 in Water Offset -0.86 in Generator Mode Enable No Limits High High Product Level Limit 105.88 in High Product Level Limit 99.13 in High Water Level Limit 2.00 in Low Product Volume Limit 2,000.0 gal Low Low Product Volume Limit 1,000.0 gal Enable Temperature Alarm Limits No Tank 4 Name Diesel 1 Type Special 4 Manifolded Yes Manifold # 2 Monthly compliance No Annual compliance No Probe Module FMS Probe Module FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 11 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Channel Diesel 1 Probe Type Standard 125 Ratio 1 to 1 tip to head Float Type 4 in diesel Water Float Yes Gradient 9.20373 µs/in Product Offset 0.00 in Water Offset -1.19 in Generator Mode Enable No Limits High High Product Level Limit 104.50 in High Product Level Limit 97.88 in High Water Level Limit 2.00 in Tank 5 Name Diesel 2 Type Special 4 Manifolded Yes Manifold # 2 Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel Diesel 2 Probe Type Standard 125 Ratio 1 to 1 tip to head Float Type 4 in diesel Water Float Yes Gradient 9.21192 µs/in Product Offset 0.00 in Water Offset -1.19 in Generator Mode Enable No Limits High High Product Level Limit 104.50 in High Product Level Limit 97.88 in High Water Level Limit 2.00 in Tank 6 Name BIO Type Special 1 Manifolded No Product # 6 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel BIO Probe Type FMP-LL3-125 Serial Number 7120072 Ratio 1 to 1 tip to head Float Type 4 in diesel Water Float Yes Gradient 9.03000 µs/in FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 12 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Product Offset 0.00 in Water Offset -1.33 in Generator Mode Enable No Limits High High Product Level Limit 107.50 in High Product Level Limit 100.00 in High Water Level Limit 2.00 in Low Product Volume Limit 2,000.0 gal Low Low Product Volume Limit 1,000.0 gal Enable Temperature Alarm Limits No Tank 7 Name DEF Type Special 1 Manifolded No Product # 7 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel DEF Probe Type Standard 149 Ratio 1 to 1 tip to head Float Type Stainless Water Float No Gradient 9.23102 µs/in Product Offset 0.00 in Generator Mode Enable No Limits High High Product Level Limit 115.00 in High Product Level Limit 99.13 in Low Product Volume Limit 2,000.0 gal Low Low Product Volume Limit 1,000.0 gal Enable Temperature Alarm Limits No Tank 8 Name OWS Type Special 5 Manifolded No Product # 8 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Annual compliance No Probe Module FMS Probe Module Channel OWS Probe Type Standard 125 Ratio 1 to 1 tip to head Float Type 2 in diesel Water Float No Gradient 9.19218 µs/in Product Offset 0.00 in FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 13 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Generator Mode Enable No Limits High High Product Level Limit 96.00 in High Product Level Limit 96.00 in Low Product Volume Limit 1,179.0 gal Low Low Product Volume Limit 1,000.0 gal Enable Temperature Alarm Limits No Special Tanks Special 1 Shape Horizontal cylinder Length Known No Capacity 19,942.0 gal Diameter 120.00 in End Type Two domed ends Dome Style Spherical Dome Radius 60.00 in Correction Table Maximum number of points 4 Data Level Volume 1: 30.00 3,925.0 2: 60.00 10,095.0 3: 90.00 16,227.0 4: 120.00 19,942.0 Special 2 Shape Horizontal cylinder Length Known No Capacity 11,624.0 gal Diameter 120.00 in End Type One domed end Dome Style Spherical Dome Radius 60.00 in Correction Table Maximum number of points 4 Data Level Volume 1: 30.00 2,477.0 2: 60.00 6,139.0 3: 90.00 9,698.0 4: 120.00 11,624.0 Special 3 Shape Horizontal cylinder Length Known No Capacity 7,852.0 gal Diameter 120.00 in End Type One domed end Dome Style Spherical Dome Radius 60.00 in Correction Table Maximum number of points 4 Data Level Volume 1: 30.00 1,590.0 2: 60.00 3,989.0 3: 90.00 6,372.0 4: 120.00 7,852.0 FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 14 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Special 4 Shape Horizontal cylinder Length Known No Capacity 29,780.0 gal Diameter 120.00 in End Type Two domed ends Dome Style Spherical Dome Radius 60.00 in Correction Table Maximum number of points 4 Data Level Volume 1: 30.00 6,456.0 2: 60.00 15,711.0 3: 90.00 24,731.0 4: 120.00 29,780.0 Special 5 Shape Horizontal cylinder Length Known Yes Length 120.00 in Diameter 96.00 in End Type Cylinder Correction Table Maximum number of points 4 Data Level Volume 1: 24.00 1,179.0 2: 48.00 3,016.0 3: 72.00 4,853.0 4: 120.00 6,032.0 Manifolds Manifold 1 Name Unleaded Product # 1 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Limits Low Product Volume Limit 2,000.0 gal Low Low Product Volume Limit 1,500.0 gal Manifold 2 Name Diesel Product # 3 Delivery Threshold 200.0 gal Theft Threshold 5.0 gal Monthly compliance No Limits Low Product Volume Limit 2,500.0 gal Low Low Product Volume Limit 2,000.0 gal Products Product 1 Name Regular Unleaded Type Unleaded regular Color White Product 2 Name Premium Unleaded Type Unleaded super Color Red FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 15 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Product 3 Name Diesel Type Diesel Color Yellow Product 6 Name BIO Type Special 1 Color Green Product 7 Name DEF Type Special 2 Color Blue Product 8 Name OWS Type #2 fuel oil Color Gray Special Products Special 1 Correction Type Table 6a API Gravity 63.500 Alpha 600.000 Density 500.0 Mole Weight 130.000 Vapor A 12.101 Vapor B 8,907.000 Special 2 Correction Type Table 6a API Gravity 63.500 Alpha 600.000 Density 500.0 Mole Weight 130.000 Vapor A 12.101 Vapor B 8,907.000 Lines Number of Lines 6 Line 1 Name Unleaded East Submersible Pump Module Power Supply Module Submersible Pump Channel Regular Unleaded 1 Controller Transducer Unleaded East Transducer Enable SLLD No Enable Yes Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Line 2 Name Unleaded West Submersible Pump Module Power Supply Module Submersible Pump Channel Regular Unleaded 2 Controller Transducer Unleaded West Transducer FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 16 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Enable SLLD No Enable Yes Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Line 3 Name Premium Submersible Pump Module Power Supply Module Submersible Pump Channel Premium Unleaded Controller Transducer Premium Unleaded Transducer Enable SLLD No Enable Yes Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Line 4 Name Diesel 1 Submersible Pump Module Power Supply Module Submersible Pump Channel Diesel 1 Controller Transducer Diesel 1 Transducer Enable SLLD No Enable Yes Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Line 5 Name Diesel 2 Submersible Pump Module Power Supply Module Submersible Pump Channel Diesel 2 Controller Transducer Diesel 2 Transducer Enable SLLD No Enable Yes FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 17 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Line 6 Name BIO Submersible Pump Module Power Supply Module Submersible Pump Channel BIO Mag Transducer BIO Transducer Enable SLLD No Enable Yes Monthly compliance No Annual compliance No Pressure Up Test Wait Time 4 sec Catch Pressure Wait Time 2 sec Dispenser Pressure Test No Catch And Sudden Pressure Loss Test No Gross Tests Enable Yes Monthly Tests Enable No Annual Tests Enable No Compliance Tracking Enable Notifications Yes Assessment Time 12:00 Rules Rule - Power On Sound Name Power On Sound Enabled Yes Events Event Type Application Event Category System Device None Code System Power On Actions Action Type Sound Frequency 2800 Hz ON Length 250 ms OFF Length 250 ms Number of Cycles 1 Rule - Application Event Sound Name Application Event Sound Enabled Yes Events Event Type Application Event Category Any Device Any Code Any FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 18 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Actions Action Type Sound Frequency 2800 Hz ON Length 250 ms OFF Length 250 ms Number of Cycles 2 Rule - New Alarm Sound Name New Alarm Sound Enabled Yes Events Event Type Alarm Occurred Category Any Device Any Code Any Actions Action Type Sound Frequency 2800 Hz ON Length 250 ms OFF Length 250 ms Number of Cycles 3 Rule - Print Inventory Daily Name Print Inventory Daily Enabled No Events Event Type Schedule Schedule Type Daily Time 06:00 Actions Action Type Report Report Name INVENTORY REPORT Report Device All Tanks Report Action Print Rule - Print Tank Test Weekly Name Print Tank Test Weekly Enabled No Events Event Type Schedule Schedule Type Custom Custom Schedules Schedule Time 06:00 Monday Yes Tuesday No Wednesday No Thursday No Friday No Saturday No Sunday No Actions Action Type Report Report Name TANK TEST REPORT FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 19 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Report Action Print Rule - Print Regulatory Monthly Name Print Regulatory Monthly Enabled No Events Event Type Schedule Schedule Type Monthly Day 1st day Time 06:00 Actions Action Type Report Report Name REGULATORY REPORT(Passed Tests) Report Action Print Rule - Print on Delivery Name Print on Delivery Enabled No Events Event Type Application Event Category FMS Device Any Code Any Actions Action Type Report Report Name DELIVERY REPORT Report Device All Tanks Report Action Print Rule - Print on Alarm Name Print on Alarm Enabled No Events Event Type Alarm Occurred Category Any Device Any Code Any Actions Action Type Report Report Name ALARM HISTORY REPORT Alarm Report Type Active Report Action Print Rule - Start Tank Test Name Start Tank Test Enabled No Events Event Type Schedule Schedule Type Daily Time 00:00 Actions Rule - Email Alarms Name Email Alarms Enabled No Events FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 20 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Event Type Alarm Occurred Category Any Device Any Code Any Actions Action Type E-Mail Address your_email@address.com Content Generated Template HTML OTB - Print Inventory Report Name Print Inventory Report Enabled Yes Events Event Type One Touch Button Button Position Upper Left Actions Action Type Report Report Name INVENTORY REPORT Report Device All Tanks Report Action Print OTB - Print Delivery Report Name Print Delivery Report Enabled Yes Events Event Type One Touch Button Button Position Upper Right Actions Action Type Report Report Name DELIVERY REPORT Report Device All Tanks Report Action Print OTB - Print Regulatory Report Name Print Regulatory Report Enabled Yes Events Event Type One Touch Button Button Position Lower Left Actions Action Type Report Report Name REGULATORY REPORT(Passed Tests) Report Action Print Rule - Overfill Name Overfill Enabled Yes Events Event Type Alarm Occurred Category FMS Device Tank Device ID Any Code High product level FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 21 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Actions Action Type Relay Module Power Supply Module Channel Overfill Action Activate Action Type E-Mail Address your_email@address.com Content Generated Template Text Action Type E-Mail Address your_email@address.com Content Generated Template Text Rule - Overfill Clear Name Overfill Clear Enabled Yes Events Event Type Alarm Cleared Category FMS Device Tank Device ID Any Code High product level Actions Action Type Relay Module Power Supply Module Channel Overfill Action Deactivate OTB - Overfill Test Name Overfill Test Enabled Yes Events Event Type One Touch Button Button Position Lower Right Actions Action Type Relay Module Power Supply Module Channel Overfill Action One Pulse Duration 5 Action Type E-Mail Address your_email@address.com Content Generated Template Text Rule - BIO Low Level Name BIO Low Level Enabled Yes Events Event Type Alarm Occurred Category FMS Device Tank FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 22 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Device ID BIO Code Low product volume Actions Action Type Relay Module Relay Module Channel BIO Low Level Action Activate Rule - BIO Low Level Clear Name BIO Low Level Clear Enabled Yes Events Event Type Alarm Cleared Category FMS Device Tank Device ID BIO Code Low product volume Actions Action Type Relay Module Relay Module Channel BIO Low Level Action Deactivate Rule - Diesel 1 High Level Name Diesel 1 High Level Enabled Yes Events Event Type Alarm Occurred Category FMS Device Tank Device ID Diesel 1 Code High product volume Actions Action Type Relay Module Relay Module Channel Diesel 1 HI Level Action Activate Rule - Diesel 1 High Level Clear Name Diesel 1 High Level Clear Enabled Yes Events Event Type Alarm Cleared Category FMS Device Tank Device ID Diesel 1 Code High product volume Actions Action Type Relay Module Relay Module Channel Diesel 1 HI Level Action Deactivate Rule - Diesel 2 High Level Name Diesel 2 High Level FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 23 of 24 1/23/2025, 10:32 PM Group Name Parameter Name Parameter Value Enabled Yes Events Event Type Alarm Occurred Category FMS Device Tank Device ID Diesel 2 Code High product volume Actions Action Type Relay Module Relay Module Channel Diesel 2 HI Level Action Activate Rule - Diesel 2 High Level Cleared Name Diesel 2 High Level Cleared Enabled Yes Events Event Type Alarm Cleared Category FMS Device Tank Device ID Diesel 2 Code High product volume Actions Action Type Relay Module Relay Module Channel Diesel 2 HI Level Action Deactivate Copyright © 2004-2016 Franklin Fueling Systems. All rights reserved. 2.10.0.8346 FFS TS-550 evo - Setup http://10.6.86.50/21008346/setup.html 24 of 24 1/23/2025, 10:32 PM