Loading...
HomeMy WebLinkAboutDERR-2025-003171Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name Diamond C Fuels Address 2041 S MAIN ST BLANDING, UT 84511 Contact Diamond C Fuels Phone Email diamondc.mike@gmail.com TANK LOCATION Name THE TRUCK STOP Address 89 E CENTER ST BLANDING, UT 84511 A Operator MIKE V. CHRISTENSEN Phone (435) 459-4686 B Operator SAME Phone SAME Facility ID: 5000194 Inspection Date: 04/15/2025 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gasoline No None None Yes No None None 2 - 3/4 Gasoline No None None Yes No None None 3 - 5/6 Gasoline No None None Yes No None None 4 - 7/8 Gas/Diesel No None None Yes No None None 5 - 9/10 Diesel No None None Yes No None None 6 - 11/12 Diesel No None None Yes No None None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / No Siphon/Compart No / No Tank Status Temporarily Out of Use Installed/Cap/Loc Aug. 29, 1985 / 10000 / East Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG Red Jacket / ST 1401 LTT Test None LLD Test None Pipe Material- Mod Fiberglass Reinforced Plastic / Secondary Containment Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model Vaporless LD2000 Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankSIR PipeAutoLineLeakDetection / PipeLineTightness CP Tank Test April 24, 2023 CP Pipe Test None 2025-04-15 Page 1 of 7 Tank ID/Alt ID 2 / 2 E-Gen/AST No / No Siphon/Compart No / No Tank Status Temporarily Out of Use Installed/Cap/Loc Aug. 29, 1985 / 10000 / Center Substance Stored Gasoline / Regular Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG Red Jacket / ST 1401 LTT Test None LLD Test None Pipe Material- Mod Fiberglass Reinforced Plastic / Secondary Containment Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model Vaporless LD2000 Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankSIR PipeAutoLineLeakDetection / PipeLineTightness CP Tank Test April 24, 2023 CP Pipe Test None Tank ID/Alt ID 3 / 3 E-Gen/AST No / No Siphon/Compart No / No Tank Status Temporarily Out of Use Installed/Cap/Loc Aug. 29, 1985 / 10000 / West Substance Stored Gasoline / Premium Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG Red Jacket / ST 1401 LTT Test None LLD Test None Pipe Material- Mod Fiberglass Reinforced Plastic / Secondary Containment Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model FE Petro MLD (blue) Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Overfill alarm / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankSIR PipeAutoLineLeakDetection / PipeLineTightness CP Tank Test April 24, 2023 CP Pipe Test None INSPECTION COMMENTS Title: UST #1 not locked 14” liquid in USTs. UST #1 & 2 locked No Photos Title: UST removal Owner plans on removing USTs before July 1. No Photos 2025-04-15 Page 2 of 7 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?No Cathodic Protection The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Temporary Closure Is release detection being maintained or is the depth of product less than 1 inch? No What is the depth of product? (Inches)14 The cathodic protection system being maintained? The tanks are locked and secured?No Tank 1 SIR/MTG SIR - Dispensers have current calibration stickers or proper calibration documentation? Yes SIR - Drop tubes are present and extend to within one foot of the tank bottom? Yes SIR - Inventory readings for product inputs, withdrawals, and the amount remaining in the tank are recorded and available for each operating day? Yes SIR - Product inputs are reconciled with delivery receipts by measurement of the tank inventory volume before and after deliveries? Yes SIR - Records include the appropriate number of water readings, and water readings are used to adjust inventory balances as necessary? Yes SIR/MTG - An appropriate calibration chart is used to convert product level readings to gallons, and is available for review? Yes SIR/MTG - Inventory readings are properly reconciled monthly (weekly and monthly for MTG) to the appropriate allowable amount? Yes SIR/MTG - Equipment used to take readings (ATG, Gauge Stick, etc.) is adequate, accessible, and operational? Yes SIR/MTG - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes Tank 1 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes Tank 2 Temporary Closure Is release detection being maintained or is the depth of product less than 1 inch? Yes What is the depth of product? (Inches)<1 The cathodic protection system being maintained?Yes The tanks are locked and secured?Yes 2025-04-15 Page 3 of 7 Tank 2 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 2 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes Tank 3 Temporary Closure Is release detection being maintained or is the depth of product less than 1 inch? Yes What is the depth of product? (Inches)<1 The cathodic protection system being maintained?Yes The tanks are locked and secured?Yes Tank 2 SIR/MTG SIR - Dispensers have current calibration stickers or proper calibration documentation? Yes SIR - Drop tubes are present and extend to within one foot of the tank bottom? Yes SIR - Inventory readings for product inputs, withdrawals, and the amount remaining in the tank are recorded and available for each operating day? Yes SIR - Product inputs are reconciled with delivery receipts by measurement of the tank inventory volume before and after deliveries? Yes SIR - Records include the appropriate number of water readings, and water readings are used to adjust inventory balances as necessary? Yes SIR/MTG - An appropriate calibration chart is used to convert product level readings to gallons, and is available for review? Yes SIR/MTG - Inventory readings are properly reconciled monthly (weekly and monthly for MTG) to the appropriate allowable amount? Yes SIR/MTG - Equipment used to take readings (ATG, Gauge Stick, etc.) is adequate, accessible, and operational? Yes SIR/MTG - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes Tank 3 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 3 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 3 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes 2025-04-15 Page 4 of 7 Tank 3 SIR/MTG SIR - Dispensers have current calibration stickers or proper calibration documentation? Yes SIR - Drop tubes are present and extend to within one foot of the tank bottom? Yes SIR - Inventory readings for product inputs, withdrawals, and the amount remaining in the tank are recorded and available for each operating day? Yes SIR - Product inputs are reconciled with delivery receipts by measurement of the tank inventory volume before and after deliveries? Yes SIR - Records include the appropriate number of water readings, and water readings are used to adjust inventory balances as necessary? Yes SIR/MTG - An appropriate calibration chart is used to convert product level readings to gallons, and is available for review? Yes SIR/MTG - Inventory readings are properly reconciled monthly (weekly and monthly for MTG) to the appropriate allowable amount? Yes SIR/MTG - Equipment used to take readings (ATG, Gauge Stick, etc.) is adequate, accessible, and operational? Yes SIR/MTG - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes DISPENSER RESPONSES Dispenser 3/4 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 7/8 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1/2 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 5/6 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes 2025-04-15 Page 5 of 7 Dispenser 11/12 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 9/10 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Apr '24 May '24 Jun '24 Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24 Jan '25 Feb '25 Mar '25 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS TANK 1 No Photos Question:Is release detection being maintained or is the depth of product less than 1 inch? Comments:None TANK 1 No Photos Question:The tanks are locked and secured? Comments:None FACILITY No Photos Question:Monthly checklist available and complete? Comments:None 2025-04-15 Page 6 of 7 Prepared by fueloperator.com Inspection Information Inspector:Wilson, David Record Created:April 15, 2025, 4:13 p.m. Inspection Date:April 15, 2025 2025-04-15 Page 7 of 7