Loading...
HomeMy WebLinkAboutDAQ-2025-002100Big West Oil LLC Upper Prediction Limit (UPL) Calculation FCC Heater H-101 NOx Data [lb/MMBtu ] (xi-x̄)2 Test 1 0.154 4.00E-06 Test 2 0.156 0.00E+00 Test 3 0.154 4.00E-06 Test 4 0.157 1.00E-06 Test 5 0.159 9.00E-06 Test 6 0.156 0.00E+00 Step Value 1) Test average (x̄)0.16 2) Size of Dataset (n)6 3) Number of values used (m)6 4) t-score (99 percent)3.365 5) Variance (s2)3.00E-06 6) UPL 0.16 Big West Oil LLC Upper Prediction Limit (UPL) Calculation Reformer Heater H-621, H-622, H-624 (Combined Stack) NOx Data [lb/MMBtu ] (xi-x̄ ) 2 Test 1 0.0606 9.40E-06 Test 2 0.0654 3.00E-06 Test 3 0.0650 1.78E-06 Step Value 1) Test average (x̄)0.06 2) Size of Dataset (n)3 3) Number of values used (m)3 4) t-score (99 percent)6.965 5) Variance (s2)7.09E-06 6) UPL 0.08