Loading...
HomeMy WebLinkAboutDAQ-2025-002126^i\wy. Dern P. Anderron Vice President Tesoro Refining & Marketing Company LLC Tesoro Refining & Marketing Company LLC A subsidiary of Marathon Petroleum Corporation April 14,2025 Mr. Bryce Bird, Director Attn: Jeremy Marsigli Utah Division of Air Quality 195 North 1950 West P.O. Box 144820 Salt Lake City, UT 841144820 First Ouarter VOC Monitorins Renort Title V Oneratinp Permit 350000E002 Condition II.8.4.a.3 & Aonroval Order: DAOE-AI\II 0335007S I 8 40 CFR 60 Subnart GGGI 860.4874 40 CFR 63 Subpart CC 863.655 Attached is the first quarter 2025 VOC monitoring report for the Tesoro Refining & Marketing Company LLC's (TMRC) Salt Lake City Refinery and Tesoro Logistics Operations, LLC (TLO). The information contained herein is for the reporting period January 1,2025, through March 31,2025. This report is required semiannually; however, TMRC Salt Lake City Refinery and TLO report quarterly. Pursuant to 40 CFR $60.a87a(c)(l-3) this report includes monitoring information pertaining to leaking components, process unit shutdowns, components placed on Delay of Repair (DOR), and applicable revisions to component inventories. This information is contained in the attached Tables l.l through 4. If you have any questions regarding this matter, please contact James Beardall 801-5214914. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are sigrrificant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. ''"S:el.. Dean P. Anderson Vice President Tesoro Refining & Marketing Company LLC 474 W 900 N DEPAT]TMENT OF ENVIRONMENTAL OUAUTY APR 1 1 '.tl1s B-2-10335 Mr. Bryce Bird, Director April 14,2025 Attachments: Table l.l- Monitoring Information for Hydrocarbon Processing Division - North Table 1.2- Monitoring Information for Hydrocarbon hocessing Division - South Table 1.3- Monitoring lnformation for Oil Movements Division Table 2.1- Revisions to lnitiaUSemiannual Report - HPDN Table2.2- Revisions to InitiaVSemiannual Report - HPDS Table 2.3- Revisions to lnitiaUSemiannual Report - OMD Table 3.1- Dates of Process Unit Shutdowns HPDN Table 3.2- Dates of Process Unit Shutdowns IIPDS Table 3.3- Dates of Process Unit Shutdowns OMD Table 4- Components on Delay of Repair Mr. Scott H. Patefield, Branch Chief USEPA Region 8 Enforcement and Compliance Assurance Division SENF-AT- Air and Toxics Enforcement Branch 1595 Wynkoop Street Denver, Colorado 80202-1129 Via USPS Hydrocarbon Processing Division - North (HPDN) Iable 1.1: Monitoring lnformation - S40 CFR 60.lt87a(c)(2) Requlrement ALKY FCCU GHT POLY VRU Jan F.b tar Jan Fcb llar Jan Fcb llar Jrn F.b tal Jan Fcb trar /alver - No. of leaks detected per i60.482- 7a(b) y'alver - No. of leaks not repaired pr 560.482-7a(dX1) 8 0 2 0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 0 0 4 0 0 0 0 0 ,umpc - No. of leaks detected per i60.482-2a(b), (dX4XiiXA) or (B) ,umpe - No. of leaks not repaired rcr $60.482-2a(c)(1) and (d)(6) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SGGa Gompreesorsl - No. of eaks detected per 560.482-3a(f) )ompressors - No. of leaks not epaired per $60.482-3a(gX1 ) 0 0 0 0 0 0 No Applicable Compressors No Applicable Compressors No Applicable Compressors 0 0 0 0 0 0 Tcsoro Rcfining Markcting Company LIC Sah Lakc City Rcltncry and Tcsoro togistics Opcrations LLC Sah Lakc City, UT Subpart GGGa VOC Monitoring Report Table 2.1: Revisions to lnitial / Semiannual Report - S40 CFR 60.487a(cX4) Requlrement ALKY FCCU GHT POLY VRU Valvesz'7 subject to S60.482-7a(a). Valves Added . Valves Removed 3169 11 12 1421 0 7 't049 0 0 805 5 2 't904 I 0 Pumps3'7 subject to $60.482-2a. Pumps Added . Pumps Removed 35 0 0 11 0 0 5 0 0 4 0 0 13 0 0 compreesors'' 7 subject to $60.482-3a. Compressors Added . Compressors Removed 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 Table 3.1: Dates of Process Unit Shutdowns- - 940 CFR 60.4E7 u^r, Process Unlt Dates of Shutdowns Scheduled (Y/N) ALKY No Shutdowns N/A FCCU No Shutdowns N/A GHT 312t2025 - 3t4t2025 POLY No Shutdowns N/A VRU No Shutdowns N/A rII\/I:iIC)N OF AIR QUALITY Page 1 of4 Hydrocarbon Processlng Dlvlslon - South (HPDS) Table 1.2: Monltorlng lnformatlon - S40 CFR 60.'187a(c)(2) Requirement BSU DDU FGR N2C UFU vNs Jan F.b mar Jan F.b ll.r Jan F.b Har Jan F.b mar Jan F.b llar Jan F.b ilar Valves - No. of leaks detected rcr 560.482- 7a(b) t/alver - No. of leaks not 'epaired per $60.a82-7a(d)(1 ) 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 ,| 0 0 0 3 0 11 0 3 0 0 0 ,| 0 0 0 Pumps. No. of leaks l€tected per 560.482-2a(b), ,dXaXii)(A)or (B) Pumps - No. of leaks not epaired per $60 .482-2a(c)(1 ) rnd (dX6) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SGOa Comprcssorsr - No. of eaks detected per 560.482- la(0 lompressors - No. of leaks rot ropaired per $60.482- la(g)(1 ) No Applicable Compressors 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 No Applicable Compressors . Tesoro Refining Marketing Company LLC Salt Lake City Refinery and Tesoro Logistics Operations LLC Salt Lake City, UT Subpart GGGa VOC Monitoring Report Table 2.2: Revlslons to lnltlal / Semlannual Report - S40 CFR 60.487a(c)(4) Requirement BSU DDU FGR N2C UFU vNs Valvcs2'7 subject to $60.482-7a(a) . Valves Add6d . Valves Removod 1291 0 0 1452 2 2 276 1 0 2060 21I 1913 1 8 733 0 1 Pumps3'7 subject to $60.482-2a . Pumps Addod . Pumps Removed 11 0 0 5 0 0 2 0 0 1',! 0 0 12 0 o 10 0 0 Comprcssorsa' 7 subject to $60.482-3a. Compressors Added . Compressors Ramoved 0 0 0 3 0 0 3 0 o 1 0 0 3 0 0 0 0 0 able 3.2: Dates of Process Unlt Shutdowns" 540 CFR 60.487 Process Unit Dates of Shutdowns Scheduled (Y/N) BSU 1t1t2025 - 3t31t2025 DDU No Shutdowns N/A FGR No Shutdowns N/A N2C 3110t2025 - 3t11t2025 UFU No Shutdowns N/A VNS 3110t2025 - 3t11t2025 Page? ot 4 Oll Movements Dlvlslon (OMD) Iable 1.3: Monltorlng lnformatlon - S40 CFR 60.487a(cX2) Requirement BLR COGEN RTF sRu TKF TLR J.n F.b llar Jan F.b trr Jan F.b llar Jan F.b Irr Jan Fob llar Jan F.b mar y'alvcs - No. of leaks letected per 560.482- 7a(b) y'alves - No. of leaks not 'epaired per $60.482-7a(dXl ) 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 ,umps - No. of leaks jetected per 560.482-2a(b), ,dXaXiiXA) or (B) ,umps - No. of leaks not 'epaired p€r 560.482-2a(cXl ) rnd (dXG) 0 0 0 0 0 0 No Applicable Light Liquid Pumps 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GGGa Compresgorsr - No. of leaks detected per $60.482. 3a(f) Comprcssors - No. of leaks not repaired per 560.482- 3a(sXl ) 0 0 0 0 0 0 0 0 0 0 0 0 No Applicable Compressors No Applicable Compressors No Applicable Compressors No Applicable Compressors . Tesoro Refining Marketing Company LLC Salt Lake City Refinery and Tesoro Logistics Operations LLC Salt Lake City, UT Subpart GGGa VOC Monitoring Report Table 2.3: Revlslons to lnltlal / Semlannual Report - S40 CFR 60.487a(c)(4) Requirement BLR COGEN RTF SRU TKF TLR Valves2'7 subiect to $60.a82-7a(a) . Valves Addsd . Valves Removed 't260 17 15 186 0 0 821 1 1 525 0 0 3346 71 62 194',! 0 0 Pumps3'7 subject to $60.482-2a. Pumps Added . Pumps Removed 11 0 0 0 0 0 I 0 0 2 0 0 73 0 0 44 0 0 Comprcssors4 7 subject to S60.482-3a . Comprsssors Added . compressors Removed 2 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Table 3.3: Dates of Process Unit Shutdowns'- 040 CFR 60.487 Process Unit Dates of Shutdowns Scheduled (Y/N) BLR No Shutdowns N/A E COGEN No Shutdowns N/A W COGEN 3t23t2025 - 3t27t2025 SRU No Shutdowns N/A TLR No Shutdowns N/A Page 3 of 4 . Tesoro Refining Marketing Company LLC Salt take City Refinery and Tesoro Logistics Operations LLC Salt Lake City, UT Subpart GGGa VOC Monitoring Report Iabte 4: Components Added to Delay of Repair (DOR)6.S40 CFR 6O.4S7a(cX2Xxi) Process Unlt Component Type LDAR Tag #Monltorlng Date Date Placed on DOR Date Repalred Date Removed from DOR None Page 4 of 4 ' Tesoro Relining Marketing Company LLC Salt Lake City Refinery and Tesoro Logistics Operations LLG salt Lake city, uT Subpart GGGa VOC Monitoring Report Table Notes 1 - Existing compressors in ALKY, COGEN, DDU, and N2C units were constructed prior to November 7,2006. Tesoro has not conducted any construction, modification, or reconstruction activities that would trigger GGGa applicability for these compressors; however due to the Utah State lmplementation Plan Section lX, Part H.1 1 (gxiv) all affected equipment is required to comply with the provisions of 60.590a to 60.593a no later than January 1,2016. The Utah SIP was adopted by the Air Quality Board on December 2,2015. 2 - Excluding those valves designated for no detectable emissions under the provisions of S60.482-7a(0, 3 - Excluding those pumps designated for no detectable emissions under the provisions of $60.482-2a(e) and those pumps complying with 560.a82-2a(0. 4 - Excluding those compressors designated for no detectable emissions under the provisions of 560.482-3a(i), S60.482-3a(h), and 60.593a(bX1). Tesoro demonstrates compressors are in hydrogen service per 60.593a(b)(3)(i). 5 - Process unit shutdown means a work practice or operational procedure that stops production from a process unit or part of a process unit during wtrich it is technically feasible to clear process material from a process unit or part of a process unit consistent with safety constraints and during which repairs can be accomplished. The following are not considered process unit shutdowns: (a) An unscheduled work practice or operational procedure that stops production from a process unit or part of a process unit for less than 24 hours. (b) An unscheduled work practice or operational procedure that would stop production from a process unit or part of a process unit for a shorter period of time than would be required to clear lhe process unit or part of the process unit of materials and start up the unit, and would result in greater emissions than delay of repair of leaking components until the next scheduled process unit shutdown. (c) The use of spare equipment and technically feasible bypassing of equipment without stopping production. 6 - For leaking components that remain in VOC service the delay of repair designation will be removed once two consecutive monthly moniloring instrument readings are below the leak definition. 7 - Component changes involving CLVS, PRVs, Heavy Liquids, or a Process Unit switch do not show up as "added'or'removed' because they have been in service; only the component class or Unit identifier has been changed. 'Tesoro Refining Marketing Company LLC Salt Lake City Refinery and Tesoro Logistics Operations LLC Salt Lake City, UT Subpart GGGa VOC Monitoring Report The lollowlng ls a llst of codes to descrlbe component types ln the report: AVO - Audio, Visual, Olfactory COMP - Compressor CLVS - Closed Vent Vapor Recovery System DTM - Difficult to Monitor GV - Components in Gas Vapor service LL - Components in Light Liquid Service PMP - Pump PRV - Pressure Relief Valve UTM - Unsafe to Monitor VLV - Valve OOS - Out of Service or not in VOC service. OEL - Open Ended Line 'Heavy Liquid" or'HL'denotes components in heavy liquid service. "Light Liquid" or'LL'denotes components in light liquid service. 'Vapor" or'GV" denotes components in gas vapor service. The followlng ls a llst of codes used to descrlbe process unlts In the report: ALKY - Alkylation Unit BSU - Benzene Saturation Unit BLR - Butane Loading Rack BP - Boiler Plant COGEN - Cogeneration Unit (East and West) DDU - Distillate Desulfurization Unit FCCU - Fluid Catalytic Cracking Unit FGR- Flare Gas Recovery Unit GHT - Gasoline Hydrotreater Unit N2C - Crude Unit #2 POLY - Polydebutanizer Unit RTF - Remote Tank Farm SRU - Sulfur Recovery Unit TKF - Tank Farm TLR - Transport Loading Rack UFU - Ultraformer VNS - Virgin Naphtha Stabilizer VRU - Vapor Recovery Unit