Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-003140
IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION PV VENT CAP SPILL BUCKET TEST STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 4/17/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 4/14/2025 Order Number: 2380065 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-Eleven 36111 2300 West Main Street State ID 1000911 Lehi, UT 84043 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 7-Eleven 36111 2300 West Main Street State ID 1000911 Lehi UT 84043 36111 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 04/14/2025 RUL PUL Vaporless LD- 2000 Vaporless LD- 2000 Vaporless LD- 2000 30 30 200 3 20 4 30 30 200 3 20 4 32 32 100 2 20 3 UT151 David Mathie NW1-2380065 Low Sulfur Diesel TTNK1 Regular:1 TTNK2 Premium:1 TTNK3 Diesel:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2380065 Date:4/14/2025 Site Name/ID:7-Eleven 36111 Address:2300 West Main Street State ID 1000911 City:Lehi State:UT Zip:84043 How Inspected: Line Test NFPA 30A PEI RP1200 Other STP PRESSURE Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-Eleven 36111 7-ELEVEN, INC. 2300 West Main Street State ID 1000911 Lehi UT 84043 1000911 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 04/14/2025 1 2 3 RUL PUL DSL VR350 VR350 VR350 19782 7901 11904 118.38 118.38 118.38 UT151 David Mathie 2300 West Main Street State ID 1000911 7-Eleven 36111 2300 West Main Street State ID 1000911, Lehi, UT 84043 36111 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 04/14/2025 ANNULAR ANNULAR FILL STP FILL STP FILL RUL PUL/DSL RUL RUL PUL PUL DSL UT151 David Mathie 2300 West Main Street State ID 1000911 7-Eleven 36111 2300 West Main Street State ID 1000911, Lehi, UT 84043 36111 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 04/14/2025 STP UDC UDC UDC UDC UDC UDC DSL 1/2 3/4 5/6 7/8 9/10 11/12 UT151 David Mathie 7-Eleven 36111 2300 West Main Street State ID 1000911 Lehi, UT 84043 1000911 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 04/14/2025 P.O. BOX 711 DALLAS, TX 75221 1 RUL 5 OPW 2 PUL 5 OPW 3 DSL 5 OPW 13 910 13 1010 1 HR 0 14 910 14 1010 1 HR 0 14 910 14 1010 1 HR 0 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-Eleven 36111 Name :TANKNOLOGY INC. Address :2300 West Main Street State ID 1000911 Lehi, UT 84043 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-766-9279 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK1 Regular RUL 19782 11612 8170 09:58 2.00 1.99 1.98 1.97 1.96 1.95 1.89 Pass TNK2 Premium PUL 7901 2831 5070 00:02 2.00 1.98 1.96 1.95 1.94 1.93 1.82 Pass Total 27683 14443 13240 All Comments: Tester :David Mathie Test Date :4/14/2025 Signature :Work Order :2380065 WO: 2380065 PVVC tested ==>CENTERRUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.18 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -4.04 Fail PVVC tested ==>CENTERRUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 4.12 Pass Neg Leak Rate (CFH)0.21 14 0.0297 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.18 Pass PVVC tested ==>EAST PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 22 0.0466 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.06 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -3.73 Fail PVVC tested ==>EAST PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.97 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.04 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0233 Total -ve LR: 0.0636 Test Date 4/14/2025 Technician Name David Mathie WO #2380065 Facility Name / Loc #7-Eleven 36111 36111 Street 2300 West Main Street State ID 1000911 City, St, Zip Lehi, UT 84043 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2380065 Site ID / Name:36111 / 7-Eleven 36111 Address:2300 West Main Street State ID 1000911 City:Lehi State:UT Zip:84043