DERR-2025-003135
Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 2/26/2025 Tanknology WO#NW1-2379767 Test Purpose COMPLIANCE Customer PO#71084930 Customer Location MURPHY OIL USA P.O. BOX 7300 EL DORADO, AR 71731 Murphy #8780 1679 West State St Pleasant Grove, UT 84062 Attn: BRAD WEINISCHKE Attn: (870) 875-7610 () Test / Inspection Description Item Tested Date Tested Result Precision Line Tightness (.1 GPH) Tank 1 Line 1 RUL 2/26/2025 Pass Precision Line Tightness (.1 GPH) Tank 1 Line 2 RUL 2/26/2025 Pass Precision Line Tightness (.1 GPH) Tank 2 Line 1 PREMIUM 2/26/2025 Pass Precision Line Tightness (.1 GPH) Tank 3 Line 1 Low Sulfur Diesel 2/26/2025 Pass Precision Line Tightness (.1 GPH) Tank 4CLEAR EO Line 1 REG - CONV(E0) 2/26/2025 Pass PEI RP 1200 Leak Detector See test report for details 2/26/2025 Pass Impact Valve Inspection See test report for details 2/26/2025 Pass RP 1200 ATG See test report for details 2/26/2025 Pass RP 1200 Sensors See test report for details 2/26/2025 Pass E-Stop Inspection See test report for details 2/26/2025 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) Product Line Tightness Test Page 1 of 1 Work Order: 2379767 Date: 2/26/2025 Site Name/ID: Murphy #8780 / 8780 Address: 1679 West State St City: Pleasant Grove State: UT Zip: 84062 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 RUL Pressure 60 10:40 11:10 0.00 Pass Yes Tank # 1 Line # 2 TLD-1 1 RUL Pressure 60 10:40 11:10 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 PREMIUM Pressure 60 10:40 11:10 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 Low Sulfur Diesel Pressure 60 10:40 11:10 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4CLEAR EO REG - CONV(E0) Pressure 60 10:40 11:10 0.00 Pass Yes Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Murphy #8780 1679 West State St Pleasant Grove UT 84062 8780 Tanknology, Inc. MURPHY OIL USA P.O. BOX 7300 EL DORADO AR 71731 870-875-7610 02/26/2025 RUL RUL Low Sulfur Diesel REG - CONV(E0)FE Petro MLD+GFE Petro MLD+GFE Petro MLD+GFE Petro MLD-DFE Petro MLD+G 32 32 325 3 10 5 32 32 325 3 10 5 30 30 325 3 10 5 33 33 325 3 10 5 30 30 325 3 10 5 UT151 RUL 2 STPS David Mathie NW1-2379767 PREMIUM TRUL:1 TRUL:2 T2:1 T3:1 TCLEAR:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2379767 Date:2/26/2025 Site Name/ID:Murphy #8780 Address:1679 West State St City:Pleasant Grove State:UT Zip:84062 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 88 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 88 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 40 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 88 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 88 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 88 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:2379767 Date:2/26/2025 Site Name/ID:Murphy #8780 Address:1679 West State St City:Pleasant Grove State:UT Zip:84062 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 88 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 40 Pass Fail Not Tested 13/14 85 Pass Fail Not Tested 13/14 88 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 85 Pass Fail Not Tested 15/16 88 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Murphy #8780 MURPHY OIL USA 1679 West State St Pleasant Grove UT 84062 8780 Tanknology, Inc. P.O. BOX 7300 EL DORADO AR 71731 870-875-7610 800-964-1250 02/26/2025 1 2 3 4 RUL PREM DSL EO FREE VR450PUS VR450PUS VR450PUS VR450PUS 25431 7901 10420 7901 118.3 118.3 118.3 118.3 UT151 David Mathie 1679 West State St Murphy #8780 1679 West State St, Pleasant Grove, UT 84062 8780 Tanknology, Inc. MURPHY OIL USA P.O. BOX 7300 EL DORADO, AR 71731 870-875-7610 02/26/2025 ANNULAR ANNULAR STP STP STP STP UDC RUL PREM/DSL/REO RUL PREM DSL REO FREE 1/2 UT151 David Mathie 1679 West State St Murphy #8780 1679 West State St, Pleasant Grove, UT 84062 8780 Tanknology, Inc. MURPHY OIL USA P.O. BOX 7300 EL DORADO, AR 71731 870-875-7610 02/26/2025 UDC UDC UDC UDC UDC UDC UDC 3/4 5/6 7/8 9/10 11/12 13/14 15/16 UT151 David Mathie Emergency Stop (E-Stop / ESO) Periodic Inspection Facility Information Technician Information Site #: Murphy #8780 8780 Date: 2/26/2025 Address: 1679 West State St Name: David Mathie City / State: Pleasant Grove UT Technician Signature: The objective of this test is to provide assurance that the when the E-Stop switch is activated, all the fueling system circuits (turbines, and dispensers) are de-energized, and remain de-energized until they are re-set manually). The test procedures and guidelines shall be in accordance with the E-Stop Testing Process. SITE DATA 1 Number of E-Stop switches INSIDE of the building: 1 2 Number of E-Stop switches OUTSIDE of the building: 2 PERFORMANCE DATA Yes No NA 3 You have added or confirmed that all E-Stop locations are on the Site Diagram 4 Do all E-Stops shutdown power to ALL DISPENSERS 5 Do all E-Stops shutdown power to ALL STP's 6 Are ALL E-Stops clearly Labeled 7 Are the TURBINE BREAKERS clearly identified / labeled POST TEST 8 All equipment secured and any access ports, lids, enclosures are closed. 9 All safety barricades and test equipment has been properly removed 10 E-Stop was reset and all dispensing functions are normal E-Stop Inspection Results 11 PASS FAIL INCONCLUSIVE Comments (Clearly describe any deficiencies found) ALSO SHUT DOWN VR450PUS CHECKED TIME ANND DATE CORRECT WO: 2379767 Murphy Oil USA Site Checklist Murphy # :8780 City, State :Pleasant Grove, UT Work Order :2379767 Tank Monitor Please Record All Sensor Alarms, Investigate, and Identify the Cause. Alarm 1:NA Cause: (Is there any free product?) Alarm 2:NA Cause: (Is there any free product?) Alarm 3:NA Cause: (Is there any free product?) Alarm 4:NA Cause: (Is there any free product?) Alarm 5:NA Cause: (Is there any free product?) Alarm 6:NA Cause: (Is there any free product?) Please check box for any issues found on tank farm and include comments below Riser Caps – (Tight) Spill Buckets – (Bad gaskets, drains, bucket liners, lids) Vapor Recovery Buckets – (Bad lids, gaskets, popetes, bucket liners) Manhole Covers STP Sump Lids Dispenser Hanging Hardware – (hoses, swivels, break-away, nozzles) Overfill Protection Stage I Vapor Recovery – (swivel dry breaks, tight fit, dual point VR) Stage II Vapor Recovery – (Vapor Saver, ?) Cathodic Protection – (Sacrificial Anodes or Impressed Current?) Are tank guage sticks or GW bailers operable and serviceable? Y Comments: WO: 2379767 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2379767 Site ID / Name:8780 / Murphy #8780 Address:1679 West State St City:Pleasant Grove State:UT Zip:84062 W.O.# NW1-2379767 Cust Ref#: 71084930 DISP PIPE PAINTED W.O.# NW1-2379767 Cust Ref#: 71084930 RUL H VALVE OPEN AS FOUND