Loading...
HomeMy WebLinkAboutDDW-2025-003849 April 2, 2025 David Kruse Division of Drinking Water P.O. Box 144830 Salt Lake City Utah Subject: Quarterly Arsenic Monitoring for 1st Quarter 2025 Dear David: This report contains the results of our Arsenic Monitoring Program for the 1st quarter of 2025. Samples were collected from 3 sites in Blue Mountain South water system 11066, 4 sites in Skyline water system 01033, 1 site in West Skyline water system 01034, and 1 site in Blue Mountain North water system 01036. The analytical laboratory results and a summary of the arsenic field-testing data should have been sent to you from Chem-Tech Ford Laboratories. All bacteriological sample results were absent from bacteria during this sampling period. The sampling results indicate that the point-of-use devices (RO units) are performing as designed and keeping the arsenic levels in compliance. It may be of interest to DDW these RO units are on a routine maintenance schedule with our vendor and as needed throughout the year. If you have any questions, please feel free to contact me at (435) 387-6028. Sincerely, Clayton Terry LNM Sampling Technician Clayton Terry LNM Sampling Technician Midwest Region Smithfield Foods PO Box 100 341 South Main Street Milford, Utah 84751 (435) 387-6028 tel (435) 387-2005 fax cterry@smithfield.com.com www.smithfieldfoods.com Sampling Results 2025 Smithfield Hog Production Farm Date Water System Incoming Arsenic (ppb) RO Arsenic (ppb) Incoming TDS RO TDS Bacteriolicical Results % TDS removal Maintenance 49170 1/7/2025 TPPOU 01033 2 0 131.2 1.2 Absent 99.1% Dry Shower 1/7/2025 TPPOU 01034 7 0 451 48.4 Absent 89.3% BM Main 1/7/2025 TPPOU 01036 3 0 470 54.5 Absent 88.4% 42100 1/7/2025 TPPOU 11066 160 2 724 122.6 Absent 83.1% STW 2/10/2025 TPPOU 01033 6 0 259 94.7 Absent 63.4%Unit was serviced WSTW 2/10/2025 TPPOU 01034 13 0 447 58.7 Absent 86.9% BMTW 2/10/2025 TPPOU 01036 2 0 458 31.6 Absent 93.1% 42108 O 2/10/2025 TPPOU 11066 160 0 700 90.8 Absent 87.0% SL Conf.3/3/2025 TPPOU 01033 6 0 259 12.4 Absent 95.2% 41319 3/3/2025 TPPOU 01034 7 0 471 36.8 Absent 92.2% BM Main 3/3/2025 TPPOU 01036 3 0 457 49.4 Absent 89.2% 42108 f 3/3/2025 TPPOU 11066 160 4 702 71.8 Absent 89.8% Blue MTN House 1/22/2025 TPPOU 11066 0.0022 #DIV/0! 42102 Office 2/24/2025 TPPOU 11066 0.0014 #DIV/0! 42105 Office 3/19/2025 TPPOU 11066 0.0121 #DIV/0! West Skyline TW 3/19/2025 TPPOU 01034 0.0016 #DIV/0! PTC 1 3/19/2025 TPPOU 01033 ND #DIV/0! PTC 2 3/19/2025 TPPOU 01033 ND #DIV/0! 41208 3/19/2025 TPPOU 01033 ND #DIV/0! 41106 Office 3/19/2025 TPPOU 01033 ND #DIV/0! Blue MTN Main.3/19/2025 TPPOU 01036 ND #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! Lab Arsenic Analysis (mg/L) The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25A1635 Project: Blue Mountain South - 1st Quarter 1/24/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 25A1635-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: POU Location Drinking Water Clayton Terry 1/22/2025 9:28 AM 1/23/2025 10:20 AM Blue Mountain South - 1st Quarter Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH11066 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 01/23/202501/23/20250.010.0022 EPA 200.8/200.8 Page 2 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 3 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25B1749 Project: Blue Mountain South - 1st Quarter 2/26/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 25B1749-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: POU 42102 Office Drinking Water Clayton Terry 2/24/2025 11:00 AM 2/25/2025 10:05 AM Blue Mountain South - 1st Quarter Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH11066 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 02/26/202502/26/20250.010.0014 EPA 200.8/200.8 Page 2 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 3 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25C1515 Project: [none] 3/24/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 25C1515-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: 42105 Office Drinking Water 3/19/2025 9:36 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH11066 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.010.0121 EPA 200.8/200.2 Page 2 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 3 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25C1516 Project: [none] 3/24/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 25C1516-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: West Skyline Truck Wash Drinking Water Clayton Terry 3/19/2025 9:55 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01034 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.010.0016 EPA 200.8/200.2 Page 2 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 3 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25C1518 Project: [none] 3/24/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 7 Certificate of Analysis 25C1518-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: PTC 1 Drinking Water Clayton Terry 3/19/2025 6:47 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01033 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.01ND EPA 200.8/200.2 Page 2 of 79632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 7 Certificate of Analysis 25C1518-02Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: PTC 2 Drinking Water Clayton Terry 3/19/2025 6:49 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01033 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.01ND EPA 200.8/200.2 Page 3 of 79632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 7 Certificate of Analysis 25C1518-03Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: 41208 Drinking Water Clayton Terry 3/19/2025 10:05 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01033 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.01ND EPA 200.8/200.2 Page 4 of 79632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 4 of 7 Certificate of Analysis 25C1518-04Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: 41106 Office Drinking Water Clayton Terry 3/19/2025 8:23 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01033 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.01ND EPA 200.8/200.2 Page 5 of 79632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 5 of 7 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 6 of 79632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 6 of 7 Page 7 of 7 The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Smithfield Hog Production Attn: Clayton Terry PO Box 100 Milford, UT 84751 Work Order: 25C1519 Project: [none] 3/24/2025 Approved By: Andrew Royer, Project Manager 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 25C1519-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: Blue MTN. Maint. Drinking Water Clayton Terry 3/19/2025 9:44 AM 3/20/2025 10:00 AM Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH01036 TPPOU TPPOU Y Smithfield Hog Production Minimum Reporting LimitParameterSample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Metals Arsenic, Total 0.0005 mg/L 03/21/202503/21/20250.01ND EPA 200.8/200.2 Page 2 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards. Values reported in BLUE exceed Secondary Drinking Water standards. BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Page 3 of 49632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4