Loading...
HomeMy WebLinkAboutDAQ-2024-011743 Small Source Registration DAQE-EN162390001-24 {{$d1 }} Maxim Zakharov Adobe Systems Inc. 3900 Adobe Way Lehi, UT 84043 zakharov@adobe.com Dear Maxim Zakharov: Re: Request for Evaluation of Compliance with Rule R307-401-9, UAC: Small Source Exemption Project Fee Code: N162390001 On November 8, 2024, the Division of Air Quality (DAQ) received your request for a small source exemption for the Adobe Systems Inc.’s Lehi Emergency Generator. The source is located at 3900 Adobe Way, Lehi, in Utah County. DAQ has determined the small source exemption applies to the source, as long as the equipment and associated processes operate as specified in the registration request. The small source exemption does not exempt a source from complying with other applicable federal, state, and local regulations and the current Utah Administrative Code. Based on the emissions that you submitted to DAQ with your registration request, Adobe Systems Inc. is not required to obtain an approval order under R307-401 for the Lehi Emergency Generator. If you change your operation such that there is an increase in emissions, we recommend that you notify us, as an approval order may be required. As authorized by the Utah Legislature, the fee for issuing this small source exemption is a one-time filing fee in addition to the actual time spent by the review engineer and all other staff on the project. Payment should be sent to DAQ upon receipt of the invoice. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director , 3 " * " / Û Ù Û Ù Û Ý DAQE-EN162390001-24 Page 2 Thank you for registering your source with the DAQ. If you have any additional questions, please contact Katie Andersen at (385) 515-1748 or kandersen@utah.gov. Sincerely, Bryce C. Bird Director {{$s }} Alan D. Humpherys, Manager New Source Review Section BCB:ADH:KA:jg {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} Engineering Submittal for Cache Valley Electric Adobe Utah Campus Phase 1 Caterpillar 3512C Packaged Generator Set, Avtron K711 Load Bank, GE Zenith Bypass-Isolation, Delayed Transition Transfer Switches and Accessories Presented By: 4901 West 2100 South Salt Lake City, Utah 84120 Ken Clement Electric Power Generation Sales Phone: 801-974-0511 ext. 1535 Fax: 801-978-1550 E-Mail: KClement@WheelerCat.com Molly Stephens Project Manager Phone: 801-974-0511 ext. 1553 Fax: 801-978-1550 E-Mail: MStephens@WheelerCat.com 4901 West 2100 South Salt Lake City, Utah 84120 Phone: 801-974-0511 Fax: 801-978-1550 Table of Contents Subject Page(s) Caterpillar 3512C Generator Set Specifications 1-5 Caterpillar 3512C Generator Set Engine Performance Data 6-9 Caterpillar 3512C Generator Set Systems Data 10-11 Caterpillar 3512C Generator Set Test Specifications 12-15 Caterpillar 824 Frame SR4B Generator Specifications 16-17 Caterpillar 824 Frame SR4B Generator Data 18-25 EMCP 4.2 Generator Set Controller 26-28 EMCP 4 Local Annunciator and Remote Annunciator 29-30 Circuit Breaker, 2500A, 100% Rated, UL Listed with Long Time, Instantaneous, Short Time and Ground Fault 31-32 Circuit Breaker, 800A, 100% Rated, UL Listed with Long Time, Short Time and Instantaneous 33-37 Caterpillar ADEM III Engine Controller 38-40 Caterpillar Dual Heavy Duty Starting Motors 41 Racor Fuel Water Seperator 42-45 Caterpillar Jacket Water Heater with Circulating Pump 47-51 SENS Energenius Battery Charger Specifications 52-55 Caterpillar Premium Starting Batteries 56 Kim Hotstart Battery Heating Pads 57 California Dynamics IBC Seismic Vibration Isolator Recommendations 58-68 Universal Nelson Silencer Specifications 69-71 Pilla Remote Emergency Stop Button 72 Caterpillar 3512C Generator Set Custom Views 73-77 Caterpillar 3512C Generator Set Electrical Drawings 78-106 Hardin Industries Bill of Materials 107-108 ALD DG-11 Parallel Blade Dampers 109-110 ALD DG-21 Parallel Blade Dampers 111-112 Morrison Bros. 244-8 Emergency Vent 113 EM Oil Equipment 4025 Mushroom Vent Cap 114 4901 West 2100 South Salt Lake City, Utah 84120 Phone: 801-974-0511 Fax: 801-978-1550 Subject Page(s) Rochester Gauges, Inc. 6580-0151-P5880S02547 Level Gauge 115 Madison M7000-Level Switch 117 Hardin Industries Generator Set Enclosure and Fuel Tank Package Drawings 118-121 Avtron Model K711 Radiator Mounted Load Bank Specifications and Drawings 122-125 GE Zenith ZBTSD Bypass-Isolation Delayed Transition Transfer Switches Specifications 126-127 GE Zenith Certificate of Seismic Compliance 128 GE Zenith Transfer Switch Warranty Rider 129-130 GE Zenith Modbus Remote Annunciator 131-138 GE Zenith ISO-2008 Certificate 139 GE Zenith UL Certificate of Compliance 141 GE Zenith ZBTS 1600A, 4 Pole Bypass-Isolation Delayed Transition Transfer Switch Mechanical Drawings 142-145 GE Zenith ZBTS 1600A, 4 Pole Bypass-Isolation Delayed Transition Transfer Switch Electrical Drawings 146-158 GE Zenith ZBTS 600A and 800A, 4 Pole Bypass-Isolation Delayed Transition Transfer Switch Mechanical Drawings 159-160 GE Zenith ZBTS 600A and 800A, 4 Pole Bypass-Isolation Delayed Transition Transfer Switch Electrical Drawings 161-165 Building Code: A li d l d SEISMIC CALCULATION WORKSHEETCATERPILLAR 3512C PROJECT IBC-2006 / ASCE 7-05 WHEELER POWER SYSTEMS Sds 0.902 Ip 1.5 ap 2.5 R p 2 GENSET PACKAGE z/h 0 Applied loads: W p Load combination : www.caldyn.com 33879 lbs. 0.68g Page 1 of 2: Isolator / Restraints ASD DL "CALL US - TO SET THINGS RIGHT"8/26/2011 R.R. JN11-0074 F p Wp E Applied loads: Eh Ev SDS W p Critical Angle: b I I Wp b I yy a I xx N a e x I XX e y / e x b e y I yy c Vertical reaction caused by eccentricity Vertical reaction caused by weight 14 3 in. 13533 in.² 0 in. 59246 in.² 50 in. y y y g W n Ev T w W n Tex W n ex a I yy Tisol Tey W n ey b I xx Te T ex Tey V isol Vertical reaction caused by overturning 2056 lbs. 1307 lbs. Tmx E h z a Iyy Tmy E h z b Ixx Tm T mx Tmy Calculate vertical loads Tnet Tm T e T w T isol <<<---Tension demand Isolator Section View 2056 lbs.isol Tension demand Horizontal reaction caused by direct shear & rotation V rot E h e²x e²y IXX I yy Vdir E h V isol V²rot V²dir V rot Vdir Isolator / Restraints : Use, (14x) Caldyn type 2056 lbs. 1307 lbs. JQE T i_cap >[ ] Vi_cap >[ ] 4300 lbs. 2056 lbs.2.09 PASS 3200 lbs. 1307 lbs.2.45 PASS Building Code: A li d l d SEISMIC CALCULATION WORKSHEETCATERPILLAR 3512C PROJECT IBC-2006 / ASCE 7-05 WHEELER POWER SYSTEMS Sds 0.902 Ip 1.5 ap 2.5 R p 2 GENSET PACKAGE z/h 0 Applied loads: W pwww.caldyn.com 33879 lbs. 0.68g"CALL US - TO SET THINGS RIGHT"8/26/2011 R.R. JN11-0074 F p Wp Load combination :;Applied loads:ASD DL E Page 2 of 2: Anchorage ;E h E v SDS W p ISOLATOR SELECTION: Vertical reaction caused by weight n Tw Wn h d W p (14) 2 anchors 5 i 2 5 i 5 in. d Vertical reaction caused by eccentricity Vertical reaction caused by overturning W n E v Tmx E h c a Iyy Tex W n ex a I yy Tmy E h c b Ixx Tey W n ey b I xx Tm T mx Tmy Te T ex Tey W p 5 in.2.5 in. e ex ey Calculate vertical loads (worst case per mounting point) Tnet Tm T e T w Tnet <<<---Tension demand Horizontal reaction caused by direct shear & rotation V rot E h e²x e²y IXX I yy Vdir E h ²² 493 lbs. V net V²rot V²dir V rot Vdir Calculate anchor pullout load Tnet Tanch Tanch Vnet h T net d 2 d V net Calculate anchor shear load V anch 493 lbs. 1554 lbs. 1307 lbs. 654 lbs. 1307 lbs. hCalculate anchor shear load anch V anch V net n ANCHORAGE REQUIREMENTS:ANCHOR CAPACITIES: A307 STEEL HEX HEAD BOLT Tcap (2) anchors per isolator V cap 6900 lbs. 3680 lbs. 654 lbs. 654 lbs. (28) 5/8''Ø d CHECK ANCHORAGE:T anch Tcap V anch V cap Tanch1.0 1554 lbs. PASS Isolator Section View Equipment Details Rating 2,010 hp = (1500 kw)Operational Hours 10 hours/year Source wants to show 10 hours be Sulfur Content 15 ppm or 0.0015% Criteria Pollutant EmissionStandards(g/hp-hr)Emission Factor(lb/hp-hr) EmissionRate(lbs/hr) EmissionTotal(tons/year)Reference NOX 0.58 2.57 0.01CO0.44 1.95 0.01PM100.03 0.13 0.00PM2.5 0.03 0.13 0.00 VOC 0.11 0.49 0.00SO21.21E-05 0.02 0.00 AP-42 Table 3.4-1HAP0.02 0.00 See Below Green House Gas Pollutant Global Warming Potential Emission Factor(lb/hp-hr) EmissionRate(lbs/hr) EmissionTotal(tons/year)ReferenceCO2 (mass basis)1 1.16 2,332 12 Methane (mass basis)25 6.35E-05 0 0CO2e12 Hazardous Air Pollutant EmissionRate(lbs/hr) EmissionTotal(tons/year)ReferenceBenzene7.76E-04 1.09E-02 5.46E-05Toluene2.81E-04 3.95E-03 1.98E-05Xylenes1.93E-04 2.72E-03 1.36E-05 Formaldehyde 7.89E-05 1.11E-03 5.55E-06Acetaldehyde2.52E-05 3.55E-04 1.77E-06Acrolein7.88E-06 1.11E-04 5.54E-07Naphthalene1.30E-04 1.83E-03 9.15E-06Acenaphthylene9.23E-06 1.30E-04 6.49E-07Acenaphthene4.68E-06 6.58E-05 3.29E-07Fluorene1.28E-05 1.80E-04 9.00E-07Phenanthrene4.08E-05 5.74E-04 2.87E-06Anthracene1.23E-06 1.73E-05 8.65E-08Fluoranthene4.03E-06 5.67E-05 2.84E-07Pyrene3.71E-06 5.22E-05 2.61E-07Benz(a)anthracene 6.22E-07 8.75E-06 4.38E-08Chrysene1.53E-06 2.15E-05 1.08E-07Benzo(b)fluoranthene 1.11E-06 1.56E-05 7.81E-08Benzo(k)fluoranthene 2.18E-07 3.07E-06 1.53E-08Benzo(a)pyrene 2.57E-07 3.62E-06 1.81E-08Indeno(1,2,3-cd)pyrene 4.14E-07 5.82E-06 2.91E-08Dibenz(a,h)anthracene 3.46E-07 4.87E-06 2.43E-08Benzo(g,h,l)perylene 5.56E-07 7.82E-06 3.91E-08 AP-42 Table 3.3-1& Table 3.4-1 Emission Factor(lb/MMBtu) AP-42 Table 3.3-2,Table 3.4-3, &Table 3.4-4 (1,3-Butadiene will not popluate if the engine size is greater than 600 hp. AP-42 does not list 1,3-Butadiene for engines greater than 600 hp.) Diesel-Fired Engines Emergency Engines should equal 100 hours of operation per year Manufacturer Data,AP-42 Table 3.3-1,& Table 3.4-1 Page 1 of Version 1.1 February 21, 2019 Response Summary: To be eligible businesses shall not do any of the follow: 1) Emit more than 5 tons per year of each of the following pollutants: Sulfur Dioxide (SO2), Carbon Monoxide (CO), Nitrogen Oxides (NOx), Particulate Matter (PM10), Ozone (O3), or Volatile Organic Compounds (VOCs). 2) Emit more than 500 lbs/yr of any single Hazardous Air Pollutant (HAP), and emit more than 2000 lbs/yr of any combination of HAPs 3) Emit more than 500 lbs/yr of any combination of air contaminants not listed in 1 or 2 A copy of this registration notice and worksheets are required on site to verify permit exemption status. Please be aware a the Small Source Exemption ONLY exempts the site from the air permitting requirements of R307- 401-5 thru R307-401-8 of the Utah Administrative Code, all other air quality regulations still apply. Q4. Please fill out the following contact information: Site Contact Site Owner Name Maxim Zakharov Adobe Adobe Systems Inc. Mailing Address 3900 Adobe Way 3900 Adobe Way 3900 Adobe Way Mailing Address 2 NA NA NA City Lehi Lehi Lehi State Utah Utah Utah Zip Code 84043 84043 84043 Phone 1-512-998-0955 1-512-998-0955 1-512-998-0955 Fax NA NA NA Email zakharov@adobe.com zakharov@adobe.com zakharov@adobe.com Q5. County the Site is located in: Utah County Q6. Briefly describe the process including the end products, raw materials, and process equipment used. Standby generator for critical IT equipment. Q7. List emission units NOx 5.8 per g/hp-hr CO .44 g/hp-hr HC .11 g/hp-hr PM .03 g/hp-hr Q8. List any pollution control equipment None. Q9. Please include Annual Emission Rates calculation spreadsheet. [Click here] Q11. Contact Information: (person filling out form - signature will be required) Name Korby Connell Title Building Engineer Phone 801-874-4322 Date 11/08/24 Q10. By signing below, I hereby certify that the information and data submitted in this notice fully describes this site and ONLY this site. The information provide is true, accurate, and complete to the best of my knowledge. I understand that I am responsible for determining whether the site remain eligible for this exemption before making operational or process changes in the future, and agree to notify the Division of Air Quality when this site is not longer eligible for this exemption. (Signature of Owner/Manager) [Click here] Embedded Data: N/A