Loading...
HomeMy WebLinkAboutDAQ-2024-011078 Small Source Registration DAQE-EN116230003-24 {{$d1 }} Ulysses Davis National Oceanic and Atmospheric Administration - National Weather Service Salt Lake City Office 2242 West North Temple Street Salt Lake City, UT 84116 ulysses.davis@noaa.gov Dear Ulysses Davis: Re: Request for Evaluation of Compliance with Rule R307-401-9, UAC: Small Source Exemption Project Fee Code: N116230003 On September 10, 2024, the Division of Air Quality (DAQ) received your request for a small source exemption for the National Oceanic and Atmospheric Administration (NOAA)-National Weather Service (NWS) Salt Lake City Office. The source is located at 2242 West North Temple Street in Salt Lake City, Salt Lake County. On-site equipment includes one (1) diesel-fired, 376 horsepower (380 kilowatt) emergency generator engine. DAQ has determined the small source exemption applies to the source, as long as the equipment and associated processes operate as specified in the registration request. The small source exemption does not exempt a source from complying with other applicable federal, state, and local regulations and the current Utah Administrative Code. Based on the emissions that you submitted to DAQ with your registration request, the NAAO-NSW Salt Lake City Office is not required to obtain an approval order under R307-401. If you change your operation such that there is an increase in emissions, we recommend that you notify us, as an approval order may be required. As authorized by the Utah Legislature, the fee for issuing this small source exemption is a one-time filing fee in addition to the actual time spent by the review engineer and all other staff on the project. Payment should be sent to DAQ upon receipt of the invoice. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director " - 1 " * " / Ú Û Û Ù Û Ý DAQE-EN116230003-24 Page 2 Thank you for registering your source with the DAQ. If you have any additional questions, please contact Christine Bodell at (385) 290-2690 or cbodell@utah.gov. Sincerely, Bryce C. Bird Director {{$s }} Alan D. Humpherys, Manager New Source Review Section BCB:ADH:CB:jg {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} Equipment Details Rating 376 hp = (280.6 kw) Operational Hours 100 hours/yearSulfur Content 15 ppm or 0.0015% Criteria Pollutant Emission Standards (g/hp-hr) Emission Factor (lb/hp-hr) Emission Rate (lbs/hr) Emission Total (tons/year)Reference NOX 0.031 11.66 0.58 CO 6.68E-03 2.51 0.13 PM10 2.20E-03 0.83 0.04 PM2.5 2.20E-03 0.83 0.04 VOC 2.51E-03 0.95 0.05 SO2 1.21E-05 0.00 0.00 AP-42 Table 3.4-1 HAP 0.01 0.00 See Below Green House Gas Pollutant Global Warming Potential Emission Factor (lb/hp-hr) Emission Rate (lbs/hr) Emission Total (tons/year)Reference CO2 (mass basis)1 1.15 432 22 Methane (mass basis)25 0 0CO2e22 Hazardous Air Pollutant Emission Rate (lbs/hr) Emission Total (tons/year)Reference Benzene 9.33E-04 2.46E-03 1.23E-04 Toluene 4.09E-04 1.08E-03 5.38E-05 Xylenes 2.85E-04 7.50E-04 3.75E-051,3-Butadiene 3.91E-05 1.03E-04 5.15E-06 Formaldehyde 1.18E-03 3.11E-03 1.55E-04 Acetaldehyde 7.67E-04 2.02E-03 1.01E-04 Acrolein 9.25E-05 2.43E-04 1.22E-05 Naphthalene 8.48E-05 2.23E-04 1.12E-05 Acenaphthylene 5.06E-06 1.33E-05 6.66E-07 Acenaphthene 1.42E-06 3.74E-06 1.87E-07 Fluorene 2.92E-05 7.69E-05 3.84E-06 Phenanthrene 2.94E-05 7.74E-05 3.87E-06 Anthracene 1.87E-06 4.92E-06 2.46E-07 Fluoranthene 7.61E-06 2.00E-05 1.00E-06 Pyrene 4.78E-06 1.26E-05 6.29E-07 Benz(a)anthracene 1.68E-06 4.42E-06 2.21E-07 Chrysene 3.53E-07 9.29E-07 4.65E-08 Benzo(b)fluoranthene 9.91E-08 2.61E-07 1.30E-08 Benzo(k)fluoranthene 1.55E-07 4.08E-07 2.04E-08 Benzo(a)pyrene 1.88E-07 4.95E-07 2.47E-08 Indeno(1,2,3-cd)pyrene 3.75E-07 9.87E-07 4.94E-08 Dibenz(a,h)anthracene 5.83E-07 1.53E-06 7.67E-08 Benzo(g,h,l)perylene 4.89E-07 1.29E-06 6.44E-08 AP-42 Table 3.3-2, Table 3.4-3, & Table 3.4-4 (1,3-Butadiene will not popluate if the engine size is greater than 600 hp. AP-42 does not list 1,3- Butadiene for engines greater than 600 hp.) Diesel-Fired Engines AP-42 Table 3.3-1 & Table 3.4-1 Manufacturer Data, AP-42 Table 3.3-1, & Table 3.4-1 Emission Factor (lb/MMBtu) Emergency Engines should equal 100 hours of operation per year Page 1 of 1 Version 1.1February 21, 2019 Response Summary: To be eligible businesses shall not do any of the follow: 1) Emit more than 5 tons per year of each of the following pollutants: Sulfur Dioxide (SO2), Carbon Monoxide (CO), Nitrogen Oxides (NOx), Particulate Matter (PM10), Ozone (O3), or Volatile Organic Compounds (VOCs). 2) Emit more than 500 lbs/yr of any single Hazardous Air Pollutant (HAP), and emit more than 2000 lbs/yr of any combination of HAPs 3) Emit more than 500 lbs/yr of any combination of air contaminants not listed in 1 or 2 A copy of this registration notice and worksheets are required on site to verify permit exemption status. Please be aware a the Small Source Exemption ONLY exempts the site from the air permitting requirements of R307- 401-5 thru R307-401-8 of the Utah Administrative Code, all other air quality regulations still apply. Q4. Please fill out the following contact information: Site Contact Site Owner Name Ulysses Davis National Weather Service NOAA-NWS Mailing Address 2242 West North Temple St 2242 West North Temple St 2242 West North Temple St Mailing Address 2 City Salt Lake City Salt Lake City Salt Lake City State UT UT UT Zip Code 84116 84116 84116 Phone 801-524-5710 801-524-5710 801-524-5710 Fax Na NA NA Email ulysses.davis@noaa.gov ulysses.davis@noaa.gov ulysses.davis@noaa.gov Q5. County the Site is located in: Salt Lake County Q6. Briefly describe the process including the end products, raw materials, and process equipment used. One single 280KW emergency power generator. Expected to run 26 hours per year. Q7. List emission units If run 100 hours: NOx – 0.58 tons CO – 0.13 tons PM10 – 0.04 tons PM2.5 – 0.04 tons VOC – 0.05 tons SO2 – 0 tons HAP 0 tons Q8. List any pollution control equipment None. Q9. Please include Annual Emission Rates calculation spreadsheet. [Click here] Q11. Contact Information: (person filling out form - signature will be required) Name Ulysses Davis Title Electronic Systems Analyst Phone 801-524-5710 Date Sept 10, 2024 Q10. By signing below, I hereby certify that the information and data submitted in this notice fully describes this site and ONLY this site. The information provide is true, accurate, and complete to the best of my knowledge. I understand that I am responsible for determining whether the site remain eligible for this exemption before making operational or process changes in the future, and agree to notify the Division of Air Quality when this site is not longer eligible for this exemption. (Signature of Owner/Manager) [Click here] Embedded Data: N/A