Loading...
HomeMy WebLinkAboutDERR-2025-003009pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Maverik #249 295 E. Main. St. Price, UT 84501 5000196 Maverik Inc. 185 S. State St., Ste. 800 S.L.C., UT 84111 02/06/2025 1 REG V.R. PLLD 4 31 2 4 4 4 2 PRM V.R. PLLD 4 29 2 4 4 4 Max LaRou UT-412 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #249 5000196 1 REG V.R. TLS 450+ 15,269 112 4 4 4 4 95 4 1 4 4 2 PRM V.R. TLS 450+ 10,172 112 4 4 4 4 95 4 1 4 4 Max LaRou UT-412 02/06/2025 FORM 1 SUMMARY OF SOURCE TEST DATA SOURCE INFORMATION FACILITY PARAMETERS GDF Name and addresss GDF Representative and Title _________________________________ PHASE II SYSTEM TYPE (Check One) Balance ____ Hirt ____ Red Jacket ____ Hasstech ____ Healy ____Other GDF Phone No. (___)________________ Permit Conditions Source: GDF Vapor Recovery System GDF # A/C # Manifolded? Y or N Operating Parameters Number of Nozzles Served by Tank #1 ______ Number of Nozzles Served by Tank #3 ______ Number of Nozzles Served by Tank #2 ______ Number of Nozzles Served by Tank #4 ______ Applicable Regulations: VN Recommended Source Test Results and Comments Tank #: 1.Product Grade 2.Actual Tank Capacity, gallons 3.Gasoline Volume 4.Ullage, gallons (#2-#3) 5.Initial Pressure, inches H 2 O 6.Pressure After 1 Minute, inches H 2 O 7.Pressure After 2 Minutes, inches H 2 O 8.Pressure After 3 Minutes, inches H 2 O 9.Pressure After 4 Minutes, inches H 2 O 10.Final Pressure After 5 Minutes, inches H 2 O 11.Allowable Final Pressure Test Conducted by: Test Company: Date of Test: California Air Resources Board July 26, 2012 TP-201.3, Page 14 40CFR63CCCCCC Precision Testing Technologies Maverik #249 V.R.S. Dual Point 4 1 REG 15,269 8,930 2 PRM 10,172 6,967 Manifold 9,544 2.00 1.96 1.91 1.90 1.89 1.88 1.85 Max LaRou UT-412 02/06/2025 Maverik #249 California Air Resources Board October 8, 2003 TP-201.1B, Page 5 Form 1 Static Torque of Rotatable Phase I Adaptors Measurement Units: (Check Box): pound-inches pound-feet Vapor Adaptor 1 Vapor Adaptor 2 Vapor Adaptor 3 Vapor Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation:360 Rotation: 360 Rotation:360 Rotation: Product Adaptor 1 Product Adaptor 2 Product Adaptor 3 Product Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation: 360 Rotation: 360 Rotation:360 Rotation: Comments: ___________________________________________________________________ Test Company:Conducted By: Test Date:Facility Name: Facility Address:City: Precision Testing Technologies Max LaRou UT 0412 02/06/2025 Maverik #249 4 OPW 61VSA REG 65 60 60 61 Yes OPW 61SALP REG 50 50 50 50 Yes OPW 61VSA PRM 70 70 60 66 Yes OPW 61SALP PRM 45 40 35 40 Yes Yes Yes Yes Yes Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc Maverik #249 02/06/2025 Max LaRou UT-412 REG, PRM Manifold OPW 623V 4 0.04 cfh @ 2"wc 3.4"wc 0.21 cfh @ 4"wc -6.2"wc Maverik #249 Max LaRou UT-412 02/06/2025