Site 10996 (B1)
Kamren Garfield
W.W. Clyde & Co.
730 North 1500 West
Orem, Utah 84057
Dear Mr. Garfield:
Re: W.W. Clyde & Co. – Temporary Relocation/Operation, Notice of Intent – Salt Lake
County
Your Notice of Intent dated April 9, 2025, to relocate portable aggregate equipment to the
temporary project located from I-15 exit for 146000 South, go west and turn north on Pony
Express Road, Draper, Utah, was received by the Utah Division of Air Quality (DAQ) and has
been reviewed.
The following equipment has been approved for operation for this temporary project:
JCI cone/screen combo unit
JCI screen
900 kW generator
This equipment has been permitted for operation in the State of Utah by the W.W. Clyde
Company Approval Order (AO) DAQE-AN109960012-18 dated April 18, 2018. Approval is
granted to relocate and operate this equipment at the new location for a period not to exceed 180
operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of
equipment at this temporary site may be for up to 180 working days in any calendar year not to
exceed 365 consecutive days, starting from the initial relocation date. Approval is subject to the
conditions of the dust control plan submitted for this location and the above portable AO. Hours
of operation for this equipment shall be held to 16 hours each day. The maximum production rate
shall be held to the requested 600 tons per hour.
- / & ) Ú ß Û Ù Û Þ
DAQC-363-25
Page 2
Emissions for this project have been estimated at the following:
Pollutant gram/sec lbs/hr lbs/24 hr tons/yr
PM10 2.31 18.35 183.45 14.31
SOx 0.92 7.32 73.24 5.71
NOx 6.11 48.49 484.88 37.82
CO 1.60 12.67 126.69 9.88
VOC 0.25 1.98 19.75 1.54
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: Salt Lake County Health Department 4 * - - $ . — + - @ D v A ? A D ? G w D D ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Wed, Apr 9, 2025 at 11:59 AM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- W.W. Clyde & Co. has requested a Temporary Relocation. Please see the information below. Any attachments
can be access by clicking on the links.
Recipient Data:
Time Finished: 2025-04-09 11:59:35 MDT
IP: 205.197.217.202
ResponseID: R_52g9dRCuzzltkQV
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/_HdU1JVCEE_
CxjmxJmXjjelq9PKmDglnS1ztqHZueed5G5Sr7bY-o7AkIu2lf0co9n4RAsoNmSs4-P-R4Jmsdb1d4DwuYbTS4ZhOYf-
hYZQf9KWQtQ1yoQvk-jtoxEs8DsC0HEhstafjkp28elq7wRgT4Zei_VVAGuOuKRl0ziVzF2PsvEhZRMvrBu8
yC3iy6lOkWYnJWRf45Wh7h7GNwv_fj5iMRAFCwUhvDArcGJMY_K6Dto529j8mK6N7GS-
pyiyEyxgOqAl4WU5FwhUZX6rDu7Y4CneQVzFQKM9_t6hcUebtBd6PhuPrmywImyMEgSiMmOaYRLEQCUPllLRmWw
Response Summary:
Please fill out the information below:
Contact Person: Kamren Garfield
Company Name: W.W. Clyde & Co.
Mailing Address: 730 N 1500 W
City: Orem
Zip: 84057
Phone Number: 801-802-6933
Email: kgarfield@gmail.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
3B95BA44B8
Briefly give directions to the site and/or physical address:
From I-15, take exit for 146000 South, go west and turn north on Pony Express Rd.
Project is approx. 1 mile north off the west side of Pony Express Rd.
Proposed Relocation Information:
Closest City Draper
County Salt Lake
UTM X Coordinates 40.493432
UTM Y Coordinates -111.894736
Approximate distance to the nearest house/business 770 feet
UTM X Coordinates to nearest house/business 40.491420°
UTM Y Coordinates to nearest house/business -111.893301°
Does this site currently have a permit with DAQ?
4/10/25, 10:46 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1828948891188194846%7Cmsg-f:1828948891188194846&s…1/2
No
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN109960012-18
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Cone/Screen Combo Unit
Make/Model JCI K300/6203CCPM
Serial or ID# 76-6002
Manufactured Date 2022
Design Capacity 600 tph
2
Equipment Type Screen
Make/Model JCI 7203 38LP
Serial or ID# 77-1029
Manufactured Date 2002
Design Capacity 600 tph
3
Equipment Type Diesel Generator
Make/Model Caterpillar
Serial or ID# TBD
Manufactured Date TBD
Design Capacity 900 KW
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2qE2nbKLqKm9xPe
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6:00 am
Ending time of operation (am/pm) 10:00 pm
Maximum hourly production rate for project 600 tph
Expected startup date 06/19/2025
Expected completion date 12/31/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1290Z1UjB0LVL0R
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1js3aka4DmSW6ZE
4/10/25, 10:46 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1828948891188194846%7Cmsg-f:1828948891188194846&s…2/2