HomeMy WebLinkAboutDAQ-2025-000849 DAQE-GN162480001-25 {{$d1 }} Blake Downey Wasatch Environmental, Inc. 2410 West California Avenue Salt Lake City, UT 84104 bd@wasatch-environmental.com Dear Mr. Downey: RE: Notice of Intent for Installation of a New Soil Vapor Extraction System at Industry Property Project Number: N162480001 We have reviewed Wasatch Environmental, Inc.’s Notice of Intent submitted January 28, 2025, regarding the installation of a new soil vapor extraction (SVE) system to remediate the impacted soils from Industry Property located at 500 West 700 South, Salt Lake City in Salt Lake County, UT. This operation shall be done in a way to ensure that the actual emissions of volatile organic compounds (VOCs) do not exceed 5 tons/year, in accordance with R307-401-9 of the Utah Administrative Code (UAC). Also, the level of any individual hazardous air pollutant (HAP) shall not exceed the emission threshold values listed in R307-410-5(1)(c)(i)(C). Emissions estimates of VOC shall be based on test data obtained in accordance with EPA document SW-846, test 8260c or 8261A, or the most recent revision of either method. Emissions estimates of HAPs shall be based on test data obtained in accordance with EPA document SW-846, test 8021B, or the most recent revision of that method. Other test methods may be approved by the Director. Initial test samples shall be drawn on system startup. Additional test samples shall be drawn on intervals of no less than twenty-eight days and no more than thirty-one days (i.e., monthly) for the first quarter, quarterly for the remainder of the first year, and semi-annually thereafter or as determined necessary by the Director. Results of the testing and calculated annual quantity of emissions of VOC and HAPs shall be submitted to the Division of Air Quality, attention Minor Source Compliance section, within 30 days of sampling. At the anticipated level of air emissions, this project will not require an approval order, but the project will have to meet the requirements as stated in the R307-401-15 UAC. Should the actual emissions of VOC or HAPs approach the thresholds of R307-401-9(1)(a) or R307-410-5(1)(d), the SVE system shall be shut down for the remainder of the year or until an approval order can be obtained from the Division of Air Quality. Also, please note that this letter in no way releases the owner or operator of the site from any liability for compliance with all other applicable federal, state, county, and city regulations. The fee for issuing this letter is the cost, as authorized by the legislature, of the actual time spent by the review engineer and all other staff on the project. Payment should be sent to the Division of Air Quality upon receipt of the invoice. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director " / 2 / 6 Ú Û Û Ù Û Þ DAQE-GN162480001-25 Page 2 Thank you for informing the Division of Air Quality of this project. If you have any additional questions, please contact Katie Andersen who may be reached at (385) 515-1748 or kandersen@utah.gov. Sincerely, Bryce C. Bird Director {{$s }} Alan D. Humpherys, Manager New Source Review Section BCB:ADH:KA:jg {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} Vapor/Water Carbon Vessel Carbon Vessel Control Panel Air/Oil Separator Liquid Ring Pump Carbon Vessel 'A' 'B' 'C' Separator Extraction Hose Connector Manifold Typical Length = 16' Ty p i c a l W i d t h = 8 ' - 6 " Typical Height = 9' InSecondaryContainment VAPOR / WATERSEPARATOR VAPOR / OILSEPARATOR LiquidRingPump CARBON VESSEL'A' VAPOR VAPOR VA P O R / G R O U N D W A T E R Water Treatmentor Storage Tank Entrainment Pump Water SEAL OIL COLLECTIONTANK VAPOR / OIL CARBON VESSEL'B'CARBON VESSEL'C' Dischargeto Atmosphere Drafted By: 1790 N. CASE STREET ORANGE, CA 92865, US714-936-2706 ● www.calclean.com Print Date: Approved By: Designed By: LEGAL NOTICE: This is the intellectualproperty of CalClean, Inc. This designis proprietary and patent pending. It is for use by CalClean’s customers forreview purposes only. 1/23/2019 5:33:15 PM CT 2.0 Layout and Flow Diagrams Power & Data DESIGNSv2 Gordon Melin Gordon Melin using the method of treatment - - - TYPICAL Trailer Mounted MobileRemediationSystem - Carbon Filter - General Layout of CalClean Trailer Mounted MRS using the Carbon Method of Treatment Process Flow FIGUREDRAWING DATEPROJECT NO. Environmental Science and Engineering Approximate Site Boundaries 700 South 50 0 W es t Scale: 1-inch equals approximately 116 feet Sub-Slab Soil Gas Sample Exceedance Map Industry Property Salt Lake City, Utah 2627-001B January 9, 2024 4 SG-1 Chloroform - 5.21 2-Propanol - 13,600 TCE - 186 SG-2 TCE - 25.9 SG-3 TCE - 15.8 SG-4 TCE - 81.4 SG-5 2-Propanol - 18,000 TCE - 363 SG-6 Chloroform - 8.71 PCE - 597 TCE - 1,770 SG-7 Naphthalene - 7.22 TCE - 111 SG-8 TCE - 611 SG-9 Chloroform - 24.3 CIS - 3,950 TCE - 32,100 TPH LOW - 15,200SG-11 Benzene - 16.8 Chloroform - 8.32 Ethylbenzene - 323 4,180TCE - SG-10 SG-12 2-Propanol - 2,280,000 TCE - 97.0 SG-13 TCE - 517 SG-14 Ethylbenzene - 77.2 Naphthalene - 5.50 TCE - 11.3 SG-15 TCE - 257 SG-16 Chloroform - 7.54 TCE - 1,730 SG-17 TCE - 29.0 SG-18 Chloroform - 11.5 TCE - 1,990 SG-19 TCE - 152 SG-20 Chloroform - 14.0 PCE - 869 TCE - 1,100 SG-21 Chloroform - 22.6 PCE - 5,100 TCE - 6,590 SG-22 PCE - 1,320 TCE - 4,370 SG-23 TCE - 246 SG-24 Ethylbenzene - 48.6 PCE - 496 TCE - 504 SG-25 Ethylbenzene - 118 TCE - 76.6 Soil Gas Sample Location LEGEND All Concentrations are expressed in micrograms per cubic meter (µg/m3). Bold concentrations exceed the applicable U.S. EPA VISL Residential TSSGC. Bold red concentrations exceed the applicable U.S. EPA VISL Commercial TSSGC. FIGURE 1 DRAWING DATEPROJECT NO. Environmental Science and Engineering Site Location Map 2627-001E January 21, 2025 Industry Property 500 West 700 South Salt Lake City, UtahScale: 1-inch equals approximately 1,185 feet Approximate Site Boundary FIGURE 2 DRAWING DATEPROJECT NO. Environmental Science and Engineering Soil Gas Remediation Process Map Approximate Site Boundary Proposed Area of Filter Unit and GAC Vessel Discharge to Air (Location #1) Soil Gas Treatment Flow Path Proposed Area of Filter Unit and GAC Vessel Discharge to Air (Location #2) Area of Extraction Wells W 700 South 50 0 W es t W 600 South S 6 0 0 W es t 2627-001E January 21, 2025 Industry Property 500 West 700 South Salt Lake City, UtahScale: 1-inch equals approximately 97 feet Sample ID Sample Collection Date Be n z e n e Ca r b o n d i s u l f i d e Ch l o r o f o r m Ch l o r o m e t h a n e 1,4 - D i c h l o r o b e n z e n e 1,4 - D i o x a n e Eth y l b e n z e n e n- H e x a n e Na p h t h a l e n e Sty r e n e Te t r a c h l o r o e t h y l e n e (P C E ) To l u e n e Tr i c h l o r o e t h y l e n e ( T C E ) 2,2 , 4 - T r i m e t h y l p e n t a n e m& p - X y l e n e o-X y l e n e Ac e t o n e Ch l o r o b e n z e n e Cy c l o h e x a n e cis - 1 , 2 - D i c h l o r o e t h e n e tra n s - 1 , 2 - D i c h l o r o e t h e n e 1,2 - D i c h l o r o p r o p a n e Eth a n o l 4-E t h y l t o l u e n e Tr i c h l o r o f l u o r o m e t h a n e Dic h l o r o d i f l u o r o m e t h a n e 1,1 , 2 - Tr i c h l o r o t r i f l u o r o e t h a n e He p t a n e Is o p r o p y l b e n z e n e Me t h y l e n e C h l o r i d e 2-B u t a n o n e ( M E K ) 2-P r o p a n o l Pr o p e n e Te t r a h y d r o f u r a n 1,1 , 1 - T r i c h l o r o e t h a n e 1,2 , 4 - T r i m e t h y l b e n z e n e 1,3 , 5 - T r i m e t h y l b e n z e n e TP H L o w F r a c t i o n a t i o n 1,1 - D i f l u o r o e t h a n e 1,2 , 3 - T r i m e t h y l b e n z e n e Ch l o r o d i f l u o r o m e t h a n e Eth y l a c e t a t e Me t h y l C y c l o h e x a n e SG-1 10/12/2023 <0.639 <0.622 5.21 1.23 <1.20 <2.27 <0.867 <2.22 <3.30 <0.851 172 2.46 186 <0.934 1.86 <0.867 158 <0.924 <0.689 5.91 1.07 <0.924 213 <0.982 1.33 2.31 <1.53 <0.818 <0.983 8.37 5.07 13,600 <2.15 <0.590 <1.09 <0.982 <0.982 <826 17.6 <0.982 <4.42 <2.27 <0.803SG-20 10/11/2023 1.74 3.83 14.0 0.675 <1.20 <2.27 2.09 2.24 <3.30 1.04 869 7.65 1,100 <0.934 7.67 3.41 411 <0.924 <0.689 71.7 15.0 <0.924 74.7 2.61 1.90 1.77 <1.53 1.36 <0.983 1.07 20.1 337 2.45 <0.590 <1.09 3.09 <0.982 2,660 <13.5 <0.982 <4.42 <2.27 <0.803SG-21 10/11/2023 3.87 3.30 22.6 0.659 1.50 2.54 2.48 3.15 <3.30 <0.851 5,100 6.37 6,590 <0.934 7.89 3.08 240 <0.924 1.21 39.6 17.0 <0.924 76.2 1.07 2.17 2.35 <1.53 1.97 <0.983 <0.694 22.8 57.0 <2.15 <0.590 1.25 1.81 <0.982 10,000 <13.5 <0.982 <4.42 <2.27 2.35SG-22 10/11/2023 2.34 3.55 <0.973 <0.413 <1.20 <2.27 1.27 <2.22 <3.30 <0.851 1,320 <1.88 4,370 <0.934 5.33 2.48 216 <0.924 <0.689 <0.793 5.31 <0.924 147 1.55 1.66 2.11 <1.53 <0.818 <0.983 8.92 10.7 100 <2.15 <0.590 26.9 2.40 <0.982 5,660 37.8 <0.982 6.30 <2.27 <0.803SG-23 10/11/2023 1.67 <0.622 <0.973 <0.413 <1.20 <2.27 1.66 3.81 <3.30 <0.851 320 <1.88 246 <0.934 5.72 2.22 104 <0.924 <0.689 <0.793 <0.793 <0.924 270 <0.982 1.63 2.17 <1.53 <0.818 <0.983 13.3 17.3 105 <2.15 <0.590 <1.09 1.47 <0.982 971 37.00 <0.982 <4.42 14.8 <0.803SG-24 10/11/2023 2.73 <0.622 <0.973 <0.413 <1.20 <2.27 48.6 4.09 <3.30 <0.851 496 <1.88 504 <0.934 191 58.5 24.0 <0.924 <0.689 <0.793 <0.793 <0.924 107 2.77 2.23 2.27 <1.53 <0.818 <0.983 6.70 5.04 144 <2.15 <0.590 <1.09 2.09 <0.982 1,410 35.9 <0.982 <4.42 <2.27 <0.803SG-25 10/11/2023 1.51 <0.622 <0.973 <0.413 <1.20 <2.27 118 2.88 <3.30 <0.851 89.6 <1.88 76.6 <0.934 507 164 111 <0.924 <0.689 <0.793 <0.793 <0.924 353 2.15 11.6 2.41 2.08 <0.818 4.88 4.51 5.57 1,080 <2.15 <0.590 <1.09 2.46 <0.982 1,350 <13.5 <0.982 <4.42 <2.27 <0.803 1.98 1.53 5.97 0.37 0.21 0.36 24.87 2.31 0.00 0.15 1195.23 2.35 1867.51 0.00 103.78 33.38 180.57 0.00 0.17 16.74 5.48 0.00 177.27 1.45 3.22 2.20 0.30 0.48 0.70 6.12 12.37 2203.29 0.35 0.00 4.02 1.90 0.00 3150.14 18.33 0.00 0.90 2.11 0.34 0.0000000033 0.0000000026 0.0000000101 0.0000000006 0.0000000004 0.0000000006 0.0000000419 0.0000000039 0.0000000000 0.0000000003 0.0000020146 0.0000000040 0.0000031478 0.0000000000 0.0000001749 0.0000000563 0.0000003044 0.0000000000 0.0000000003 0.0000000282 0.0000000092 0.0000000000 0.0000002988 0.0000000024 0.0000000054 0.0000000037 0.0000000005 0.0000000008 0.0000000012 0.0000000103 0.0000000208 0.0000037137 0.0000000006 0.0000000000 0.0000000068 0.0000000032 0.0000000000 0.0000053097 0.0000000309 0.0000000000 0.0000000015 0.0000000036 0.00000000060.04 0.03 0.13 0.01 0.00 0.01 0.54 0.05 0.00 0.00 26.11 0.05 40.80 0.00 2.27 0.73 3.94 0.00 0.00 0.37 0.12 0.00 3.87 0.03 0.07 0.05 0.01 0.01 0.02 0.13 0.27 48.13 0.01 0.00 0.09 0.04 0.00 68.81 0.40 0.00 0.02 0.05 0.010.52 0.40 1.57 0.10 0.06 0.10 6.52 0.61 0.00 0.04 313.31 0.62 489.54 0.00 27.20 8.75 47.33 0.00 0.05 4.39 1.44 0.00 46.47 0.38 0.84 0.58 0.08 0.12 0.18 1.61 3.24 577.56 0.09 0.00 1.05 0.50 0.00 825.77 4.80 0.00 0.24 0.55 0.09 2,366.69 Without running the effluent through the GAC vessels. 849.33 Without running the effluent through the GAC vessels.NOTES:Only analytes that were detected at concentrations above the laboratory reporting limit in one or more samples are presented in the table.< = Concentration was below the laboratory detection limit.Assumes CFM of 300 with a 30-day month. = HAP all concentrations are expressed in micrograms per cubic meter (µg/m3), unless otherwise noted Table 1Soil Gas Analytical Data and Estimated Emissions CalculationsIndustry PropertyApproximately 500 West and 700 SouthSalt Lake City, UT Pounds Per 1 Month Event Pounds Per 1 YearTotal VOCs/Year (lbs)Total HAPS VOCs/Year (lbs) Average ConcentrationPounds Per Cubic Meter Katie Andersen <kandersen@utah.gov> Industry Small Source Exemption Application 6 messages Katie Andersen <kandersen@utah.gov>Wed, Jan 22, 2025 at 3:50 PM To: mc@wasatch-environmental.com Hello Michael Cronin, The Utah Division of Air Quality received your application for a Small Source Exemption on January 21, 2025 for the 30- Day Pilot Test of VOC removal. I've been assigned as the project engineer for this Small Source Exemption. I have a question regarding your application. From the brief description you provided, it sounds like this is a soil remediation project. If this is the case, please fill out this form. If that is not the case, would you mind providing more detail about what the processes at the site are? I may have more follow up questions. Cheers, Katie Andersen -- Katie Andersen Environmental Engineer | Minor NSR Section M: (385) 515-1748 airquality.utah.gov Michael Cronin <mc@wasatch-environmental.com>Wed, Jan 22, 2025 at 3:56 PM To: Katie Andersen <kandersen@utah.gov> Cc: Blake Downey <bd@wasatch-environmental.com>, Jacob Scott <js@wasatch-environmental.com> Kae, The remediaon technology is intended to address soil, soil gas, and groundwater. It’s mul-phase extracon so we will generate both a groundwater waste stream and a soil gas waste stream, both of which will be treated prior to discharge. So, it is more than a soil vapor extracon or soil venng process. Let me know if you have any addional concerns. I would be n=more than happy to answer any quesons you may have. Kind regards, Mike 2/3/25, 11:40 AM State of Utah Mail - Industry Small Source Exemption Application https://mail.google.com/mail/u/0/?ik=0900585596&view=pt&search=all&permthid=thread-a:r-8557370796970658399&simpl=msg-a:r75401970926887…1/5 Michael S. Cronin, P.G. Senior Project Geologist and Senior Project Manager Wasatch Environmental, Inc. Office: (801) 972-8400 Cell: (801) 209-5211 Email: mc@wasatch-environmental.com [Quoted text hidden] Katie Andersen <kandersen@utah.gov>Tue, Jan 28, 2025 at 9:50 AM To: Michael Cronin <mc@wasatch-environmental.com> Cc: Blake Downey <bd@wasatch-environmental.com>, Jacob Scott <js@wasatch-environmental.com> Hi Mike, With this project being a 30-day pilot project to remediate the soil and groundwater, it would be best to process this as a soil remediation project under R307-401-15 Air Strippers and Soil Vapor Extraction Systems. Then, if needed, the project could continue on until the remediation is finished. A small source exemption is mainly meant for facilities and plants that emit air pollutants during the manufacture of goods. These sources typically operate yearly as long as the company is in business. Please let me know if there are any other reasons why this project should be processed as a small source exemption. If there are no other reasons, please fill out the soil/groundwater remediation form. The link to fill out the remediation form can be found here. Cheers, Katie Andersen [Quoted text hidden] Michael Cronin <mc@wasatch-environmental.com>Tue, Jan 28, 2025 at 11:54 AM To: Katie Andersen <kandersen@utah.gov> Cc: Blake Downey <bd@wasatch-environmental.com>, Jacob Scott <js@wasatch-environmental.com> Kae, Okay, we’ll proceed accordingly. [Quoted text hidden] Katie Andersen <kandersen@utah.gov>Fri, Jan 31, 2025 at 10:48 AM To: Michael Cronin <mc@wasatch-environmental.com> Cc: Blake Downey <bd@wasatch-environmental.com>, Jacob Scott <js@wasatch-environmental.com> 2/3/25, 11:40 AM State of Utah Mail - Industry Small Source Exemption Application https://mail.google.com/mail/u/0/?ik=0900585596&view=pt&search=all&permthid=thread-a:r-8557370796970658399&simpl=msg-a:r75401970926887…2/5 Mike, We've received the soil remediation application. There seems to be some errors with the system, and we can't retrieve the documents that were attached to the application. Would you mind emailing those to me? Apologies for the inconvenience. Additionally, would you like to process this under Wasatch Environmental or under Industry Office SLC, LLC? Cheers, Katie Andersen [Quoted text hidden] Blake Downey <bd@wasatch-environmental.com>Fri, Jan 31, 2025 at 4:19 PM To: Katie Andersen <kandersen@utah.gov>, Michael Cronin <mc@wasatch-environmental.com> Cc: Jacob Scott <js@wasatch-environmental.com> Katie, Please see the attached PDFs that did not process for some reason! I have also attached the calculated yearly emissions (based on soil gas data from the area) from the remediation system. Please note, I used the average VOC concentrations, assumed that we would be running out the remediations systems max flow rate (not likely), and ran the system non-stop for a solid year (again not likely) to get these numbers. I also did not include attenuation of the VOCs from being ran through the proposed GAC system, so this estimate is very conservative as assumes we are running straight from the ground to the discharge point un-filtered! Please let mw know if you have any questions. Thank you! Blake Downey, P.G. Vice President and Senior Project Hydrogeologist Wasatch Environmental 2410 West California Avenue Salt Lake City, Utah 84104 Cell: 435-760-8269 Office: 801-972-8400 Email: BD@wasatch-environmental.com [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] [Quoted text hidden] 2/3/25, 11:40 AM State of Utah Mail - Industry Small Source Exemption Application https://mail.google.com/mail/u/0/?ik=0900585596&view=pt&search=all&permthid=thread-a:r-8557370796970658399&simpl=msg-a:r75401970926887…3/5 Katie Andersen Environmental Engineer | Minor NSR Section M: (385) 515-1748 airquality.utah.gov -- Katie Andersen Environmental Engineer | Minor NSR Section M: (385) 515-1748 airquality.utah.gov 2/3/25, 11:40 AM State of Utah Mail - Industry Small Source Exemption Application https://mail.google.com/mail/u/0/?ik=0900585596&view=pt&search=all&permthid=thread-a:r-8557370796970658399&simpl=msg-a:r75401970926887…4/5 -- [Quoted text hidden] 3 attachments Figures.pdf 1517K CLCL-CT-Typ 2.0 LD+PFD (02) BAAQMD3.pdf 220K Soil Gas Data and Emissions Calculations.pdf 117K 2/3/25, 11:40 AM State of Utah Mail - Industry Small Source Exemption Application https://mail.google.com/mail/u/0/?ik=0900585596&view=pt&search=all&permthid=thread-a:r-8557370796970658399&simpl=msg-a:r75401970926887…5/5 Response Summary: Q12. Consulting Company Information Company Name Wasatch Environmental, Inc. Address 2410 west California Ave. City salt lake city Phone 801-972-8400 Fax NA Email bd@wasatch-environmental.com Site Number 2627-001E Q5. Initial location of contamination (please include the address) Approximately the northwest corner of the 500 West and 700 South intersection located in Salt Lake City, Utah. Q8. Remediation Approach Soil Vapor extraction Q14. Please attach flow diagram [Click here] Q15. Please attach site plan of process [Click here] Q11. Contact Information: (person filling out form - signature will be required) Name blake downey Title Vice President Phone 4357608269 Date 1-28-25 Q10. By signing below, I hereby certify that the information and data submitted in this notice fully describes this site and ONLY this site. The information provide is true, accurate, and complete to the best of my knowledge. I understand that I am responsible for determining whether the site remain eligible for this exemption before making operational or process changes in the future, and agree to notify the Division of Air Quality when this site is not longer eligible for this exemption. (Signature of Owner/Manager) [Click here] Embedded Data: N/A Response Summary: To be eligible businesses shall not do any of the follow: 1) Emit more than 5 tons per year of each of the following pollutants: Sulfur Dioxide (SO2), Carbon Monoxide (CO), Nitrogen Oxides (NOx), Particulate Matter (PM10), Ozone (O3), or Volatile Organic Compounds (VOCs). 2) Emit more than 500 lbs/yr of any single Hazardous Air Pollutant (HAP), and emit more than 2000 lbs/yr of any combination of HAPs 3) Emit more than 500 lbs/yr of any combination of air contaminants not listed in 1 or 2 A copy of this registration notice and worksheets are required on site to verify permit exemption status. Please be aware a the Small Source Exemption ONLY exempts the site from the air permitting requirements of R307- 401-5 thru R307-401-8 of the Utah Administrative Code, all other air quality regulations still apply. Q4. Please fill out the following contact information: Site Contact Site Owner Name Michael Cronin Industry Industry Office SLC, LLC Mailing Address 2410 W. California Ave.650 S. 500 W.6330 S. 3000 E., Suite 630 Mailing Address 2 NA NA NA City Salt Lake City Salt Lake City Cottonwood Heights State Utah Utah Utah Zip Code 84104 84101 84121 Phone 801-972-8400 208-284-7000 208-284-7000 Fax NA NA NA Email mc@wasatch- environmental.com kristian@catalystoz.com kristian@catalystoz.com Q5. County the Site is located in: Salt Lake County Q6. Briefly describe the process including the end products, raw materials, and process equipment used. We will be conducting a 30-day pilot test which will remove VOC-impacted (mainly chlorinated solvent impacts) soil gas from beneath the project site building. The soil gas will be processed through a trailer mounted remediation system. the waste stream will be run through a vapor water separator, then a vapor oil separator, then through three 1,000 pound GAC vessels prior to discharge to the atmosphere. The system is designed to handle a VOC influent of 200 PPMV. Q7. List emission units micrograms per cubic meter. Emissions are unknown, as system has not been installed or started. I attached a soil gas table that shows data collected from the site. Please not only samples IA-12, IA-13, IA-1, IA-20, IA-21, IA-22, IA-23, and IA-24 are applicable to our pilot test. Q8. List any pollution control equipment See explanation above. Q9. Please include Annual Emission Rates calculation spreadsheet. [Click here] Q11. Contact Information: (person filling out form - signature will be required) Name blake downey Title Vice President Phone 4357608269 Date 1-21-25 Q10. By signing below, I hereby certify that the information and data submitted in this notice fully describes this site and ONLY this site. The information provide is true, accurate, and complete to the best of my knowledge. I understand that I am responsible for determining whether the site remain eligible for this exemption before making operational or process changes in the future, and agree to notify the Division of Air Quality when this site is not longer eligible for this exemption. (Signature of Owner/Manager) [Click here] Embedded Data: N/A