Loading...
HomeMy WebLinkAboutDAQ-2025-000843 DAQE-GN162490001-25 {{$d1 }} David Hansen Rockwell Solutions Incorporated 718 Bridger Lane Elk Ridge, UT 84651 rockwellutah@yahoo.com Dear Mr. Hansen: RE: Notice of Intent for Land-farming of Petroleum Impacted Soils from Sparky's Gas-n-Go Project Number: N162490001 We have reviewed your Notice of Intent submitted January 23, 2025, for land-farming of petroleum-impacted soils from Sparky's Gas-n-Go located at 94 West State Street, Orderville, in Kane County, UT. The soils will be remediated at the property of Mr. Karl Spencer, located at Universal Transverse Mercator (UTM) coordinates of 353,551 meters easting and 4,125,999 meters northing (Datum NAD83, Zone 12) in Kane County. This operation shall be done in a way to ensure that the actual emissions of volatile organic compounds (VOCs) do not exceed 5 tons/year, in accordance with section R307-401-9 of the Utah Administrative Code. Also, the level of any one individual hazardous air pollutant (HAP) or any combination of HAPs shall not exceed the toxic screening levels listed in R307-410-5(1)(d). At the anticipated level of air emissions, this project falls within the Division's rule R307-401-16 for de minimis emissions from soil aeration projects. This project will not require an air quality approval order from our office, but the project will have to meet the requirements as stated in Rule R307-401-16. Also, please note that this letter in no way releases the owner or operator of the site from any liability for compliance with all other applicable federal, state, county, and city regulations. The fee for issuing this letter is the cost, as authorized by the legislature, of the actual time spent by the review engineer and all other staff on the project. Payment should be sent to the Division of Air Quality, upon receipt of the invoice. 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director " / 2 / 6 ß Û Ù Û Þ DAQE-GN162490001-25 Page 2 Thank you for informing the Division of Air Quality of this project. If you have any additional questions, please contact Katie Andersen, who may be reached at (385) 515-1748. Sincerely, {{$s }} Alan D. Humpherys, Manager New Source Review Section ADH:KA:jg {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} DAQE-GN162490001-25 {{$d1 }} David Hansen Rockwell Solutions Incorporated 718 Bridger Lane Elk Ridge, UT 84651 rockwellutah@yahoo.com Dear Mr. David Hansen: RE: Notice of Intent for Land-farming of Petroleum Impacted Soils from Sparky's Gas-n-Go Project Number:N162490001 We have reviewed your Notice of Intent submitted January 23, 2025, for land-farming of petroleum impacted soils from Sparky's Gas-n-Go located at 94 West State Street, Orderville in Kane County, UT. The soils will be remediated at the property of Mr. Karl Spencer, located at Universal Transverse Mercator (UTM) coordinates of 353,551 meters easting and 4,125,999 meters northing (Datum NAD83, Zone 12) in Kane County. This operation shall be done in a way to ensure that the actual emissions of volatile organic compounds (VOCs) do not exceed 5 tons/year, in accordance with section R307-401-9 of the Utah Administrative Code. Also, the level of any one individual hazardous air pollutant (HAP) or any combination of HAPs shall not exceed the Toxic Screening levels listed in R307-410-5(1)(d). At the anticipated level of air emissions, this project falls within the Division's rule R307-401-16 for de-minimis emissions from soil aeration projects. This project will not require an air quality approval order from our office, but the project will have to meet the requirements as stated in the Rule R307-401-16. Also, please note that this letter in no way releases the owner or operator of the site from any liability for compliance with all other applicable federal, state, county, and city regulations. The fee for issuing this letter is the cost, as authorized by the legislature, of the actual time spent by the review engineer and all other staff on the project. Payment should be sent to the Division of Air Quality, upon receipt of the invoice. Thank you for informing the Division of Air Quality of this project. If you have any additional questions, please contact Katie Andersen, who may be reached at (385) 515-1748. Sincerely, {{$s }} 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director DAQE-GN162490001-25 Page 2 Section Manager NSR, Manager New Source Review Section XXX:XXX:XX cc: , {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} Sparky's Gas-n-Go Orderville UT Landfarming Emission Calculations Soil Contamination Concentrations: Compound mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kgBenzene0.01 2.22 6.44 1.99 0.13 0.05 0.08 0.27 0.15EthylBenzene0.03 58.7 66.1 0.28 0.03 0.4 1.25 70.9 0.03 Lead 0 0 0 0 0 0 0 0 0Methyl tert-butyl ether 0.01 1.23 0.2 0.24 0.1 0.01 0.01 0.18 0.01Naphthalene0.03 39 20.2 0.1 0.03 0.03 0.03 6.55 0.03Toluene0.03 49.9 163 0.08 0.03 0.12 0.08 7.38 0.03 Xylene 0.03 489 437 1.55 0.03 0.4 1.25 70.9 0.03Total TPH 61.3 5860 2703 70.38 59.297 61.5 63.75 1133 60.298 Average Concentration mg/kg Benzene 1.26EthylBenzene21.97Lead0.00 Methyl tert-butyl ether 0.22Naphthalene7.33Toluene24.52Xylene111.13 Total TPH 1119.17 Project Data: Contaminated Volume:400 cubic yards 305.82 cubic metersSoil Density:1.50 tons/cubic yard 1781.43 kilogram/cubic meterAir Density:0.0808 pounds/cubic foot 1.30 kilograms/cubic meterLandfarm Area:75000 square feet 6967.73 square meters Landfarm Depth:12 inches 0.30 meters Emisson Calculation Equation:(Average Soil Concentration) * (Contaminated Volume)* (Soil Density) * (1/1000000 kg/mg) * (2000 lbs/ton) * 0.5 (biodegredation) Emission Summary:lbs kg ppmv ETVBenzene0.756 0.343 0.0002 0.02EthylBenzene13.18 5.98 0.0044 3.33 Lead 0.00 0.00 NA See noteMethyl tert-butyl ether 0.13 0.06 0.0000 1.33Naphthalene4.40 2.00 0.0015 0.33 Toluene 14.71 6.68 0.0049 3.33 Xylene 66.68 30.27 0.0220 10.00Total TPH 671.50 304.86 NA See note This is a criteria pollutant. There is no ETV for this. The exemption level for this compound is: 10,000 pounds for TPH, 1,200 pounds for Lead. ETV is in ppmv. Rockwell Solutions, Inc. 718 E Bridger Lane Elk Ridge, UT 84651 (801) 361-2930 January 23, 2025 Mr. Alan Humpherys Department of Environmental Quality, Division of Air Quality PO Box 144840 Salt Lake City, Utah 84114-4840 Re: Notice to Treat Contaminated Soil Sparky’s Gas-n-Go (Former CBS Services), 94 W State Street, Orderville, Utah Facility ID: 6000142 LUST ID: NNZ Dear Mr. Humpherys: The subject site is an inactive gas station in Orderville, Utah. A release from the UST system was reported at the site in May 2017. Excavation of contaminated soil will be necessary to remediate the property. Figure 1 shows the site and the proposed excavation area. Soil sample results from areas in and near the future excavation area are shown on the attached table. A nearby landowner, Karl Spencer, has offered some of his property as an area to landfarm contaminated soil. Figure 2 shows the location of the proposed Spencer landfarm property. The landfarm will be prepared by constructing a two-foot high dirt berm and then spreading the impacted soil out on in a thickness of approximately twelve to eighteen inches inside of the berm. Mr. Spencer will turn the soil occasionally with his equipment. To confirm hydrocarbon removal of the treated soil in the landfarm to less than the Initial Screening Levels, confirmation samples will be collected and analyzed for MBTEXN and total petroleum hydrocarbons-gasoline range organics (TPH-GRO) using EPA Method 8260 and TPH-diesel range organics (TPH-DRO) using EPA method 8015. If you have any questions, please contact me at (801) 361-2930 or rockwellutah@yahoo.com. Thank you, David S. Hansen Certified UST Consultant CC 130 Rockwell Solutions, Inc. NORTH Approx. scale in feet 00 20 SS-N,GW-N, USC-1 Figure 1 Proposed Excavation Map Sparky’s Gas n Go 94 W State Street Orderville, Utah SE B-7 NE NW SWEstimated Excavation Area D-2 Sample Location B-4 B-2 B-3 D-S, B-1 D-N NORTH SS-N,GW-N, USC-1 Figure 2 Landfarm Location Area SITE Proposed Landfarm Proposed Landfarm Excavation Area Sparky’s Gas n Go 94 W State Street Orderville, Utah Sample Date Benzene (mg/kg) Toluene (mg/kg) Ethyl- benzene (mg/kg) Xylenes (mg/kg) Naph- thalene (mg/kg) MTBE (mg/kg) TPH- GRO (mg/kg) TPH-DRO (mg/kg) D-N ,4-5' 4/28/2017 <0.01 <0.03 <0.03 <0.03 <0.03 <0.01 <0.3 <61 D-S, 9-10' 4/28/2017 2.22 49.9 58.7 489 39 <1.23 1,480 4,380 B-1, 15' 1/27/2018 6.44 163 66.1 437 20.2 <0.2 2,290 413 B-1, 35' 1/27/2018 1.99 0.08 0.28 1.55 0.1 0.24 9.38 <61 B-1, 40' 8/23/2018 0.13 <0.03 <0.03 <0.03 <0.03 0.1 <0.297 <59 B-2, 15' 1/27/2018 0.05 0.12 0.04 0.4 <0.03 <0.01 1.5 <60 B-3, 15' 1/27/2018 0.08 0.08 0.1 1.25 <0.03 <0.01 3.75 <60 B-4, 15' 1/27/2018 0.27 7.38 13.7 70.9 6.88 <0.18 748 385 B-4, 35' 8/23/2018 0.15 <0.03 <0.03 <0.03 <0.03 <0.01 <0.298 <60 0.2 9 5 142 51 0.3 150 500 0.9 25 23 142 51 0.3 1,500 5,000 MBTEXN and TPH-GRO analyzed by EPA Method 8260. TPH-DRO analyzed by EPA Method 8015 Shaded cells indicate concentrations that exceed Tier 1 levels RBCA Tier 1 Screening Table 1 Initial Screening Levels Sparky's Gas n Go (Former CBS Services) 94 West State Street, Orderville, Utah (#6000142) Soil Sample Results