Loading...
HomeMy WebLinkAboutDERR-2024-005513 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-096-24 April 2, 2024 Danny Patten Lee’s Roundup No. 1 of Lehi, Inc. 1531 North State Street Lehi, Utah 84043 Re: Closure Plan Approval for Petroleum Storage Tank Lines Lee’s Roundup of Lehi, located at 1531 North State Street, Lehi, Utah Facility Identification No. 1000723 Dear Mr. Patten: The Closure Plan for the above-referenced facility, received by the Division of Environmental Response and Remediation (DERR) on March 5, 2024, has been approved subject to the noted modifications, if any. The DERR office must be notified three business days before beginning closure activities. The local fire department and other local agencies may have additional requirements for closure or may charge inspection fees. The Closure Plan Approval is effective for a period of one year from the date of approval. If closure does not take place within one year, submittal of a new Closure Plan will be required, unless otherwise approved by the Division Director. Any change to the approved Closure Plan must be submitted, in writing, and approved by the Division Director before implementation. If contamination is suspected or found during closure activities, you must report it to the DERR at (801) 536-4100 within 24 hours of discovery. Enclosed is a copy of the Closure Notice Form, which must be completed and submitted to the Division Director after the closure is performed. Please submit the environmental and Unified Soil Classification sample analysis data and chain-of-custody forms with the closure notice as soon as possible, but no later than 90 days after tank closure. Also, a final Site Plat that meets the requirements outlined in R311-204-4(2)(b) must be submitted with the closure notice. Facility ID# 1000723 Page 2 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper If you have additional questions, please contact Laura Perdue, the DERR project manager, at (256) 656-2847. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/LP/ta Enclosure: Closure Notice Form cc:Eric Edwards, Executive Director, Utah County Health Department Jeremy L. Craft, Fire Chief, Lehi Fire Department if ~ ~ J 1 UNDERGROUND STORAGE TANK CLOSURE PLAN (rev. 7/13) FACILITY ID# 1000723 … LHD USE ONLY Date Received Reviewer Date LHD Approved Date mailed to State Closure Plan prepared at the request of the owner/operator (identified below) by Russell J. Hicks of (company name) Push Drilling, LLC Phone # 801-928-0101 Address 852 Chelsea Dr.City Bountiful StateUT Zip84010 A Contractor may prepare this Closure Plan as the owner/operator's agent. In preparing the Closure Plan, the Contractor must act with the owner/operator's knowledge and approval. The owner/operator must sign the Closure Plan.Submit Closure Plan to: DERR/UST, P.O. Box 144840, Salt Lake City, Utah, 84114-4840 This Closure Plan is submitted in compliance with the requirements contained in 40 CFR 280 Subpart G and R311-204 (U.A.C.) Piping closure only Tank # 1 2 3 4 Tank Type (Steel,FRP,etc.)FRP FRP FRP FRP Piping Type (Steel,FRP,etc.)Flex Flex Flex Flex Date Installed 11/2/95 11/2/95 11/2/95 11/2/95 Capacity 8,000 12,000 10,000 10,000 Substance stored*Gas Gas Diesel Diesel Date last operated Current Current Current Current Removal/In Place/Change in Service (CIS)? *Indicate the specific substance stored in each tank to be closed (gasoline, diesel, new oil, waste oil, etc.) For waste oil tanks:Have degreasing or other types of solvents been stored or mixed with the waste oil? Yes (identify if known) NA .No Not Known Analysis for lead or other contaminants may be required prior to disposal of contaminated soil or other material. (Check with your disposal facility.) STATE USE ONLY Date Received Date Mailed to LHD Date Received From LHD Reviewer/Date Approved Mgr. Review/Date FACILITY INFORMATION Tank Owner Lees Roundup No 1 of Lehi Inc.Phone # 801-768-1774 Address 1531 N State City Lehi State UT Zip 84043 Facility Name Lee's Round-Up No 1 of Lehi Address 1531 N State City Lehi State UT Zip 84043 Contact person Danny Patten Phone # 801-768-1774 Total number of regulated underground tanks at this site 4 Total number of regulated underground tanks at this site to be closed 0 03/05/24 Laura Perdue 03/07 /24 I I I I I I I I ~1 □ □ 2 Before the closure plan is submitted for approval, the local health and fire departments where the facility is located must be contacted. CONTACT LOCAL HEALTH DISTRICT: Name of Dist. UT DERR Date 3/4/24 Contact Laura Perdue Title Environmental Scientist Phone# 256-656-2847 CONTACT LOCAL FIRE DEPT. Name of Dept. Lehi Fire Dept.Date 3/4/24 Contact Garion Rowett Title Fire Inspector Phone# 801-768-7130 DISPOSAL INFORMATION Tank(s)will be disposed at: Facility Construction Waste Management Address 7213 W. California Ave.City Salt Lake City State UT Zip 84104 Contact person Scale House Phone# 801-449-9779 Product lines will either be: removed or cleaned, secured in place, and capped. Vent lines will either be: removed or cleaned and secured open. Piping will be disposed at: Facility Construction Waste Management Address 7213 W. California Ave.City Salt Lake City State UT Zip 84104 Contact person Scale House Phone# 801-449-9779 Tank(s) will be emptied by: company NA Phone# Tank(s) will be cleaned by: company Phone# Contaminated water in the tank/rinsate will be disposed at: Facility Contact person Phone# Tank(s)will be: purged or rendered inert by the following method: Residual sludges will be disposed at the following facility: Address City State Zip Contact person Phone# FOR CLOSURE IN PLACE ONLY For this closure method, you are subject to the requirements of UAC R315-302-2(6), which requires annotating the property title and submitting documentation to the Division of Solid and Hazardous Waste (DSHW). For information on how to comply with these requirements, contact the DSHW Solid Waste Landfills Section Manager at (801) 536-0200. Approval for in-place closure has been granted by the Local Fire Department. (Must submit approval in writing with Closure Plan) Fire Dept. Phone# Contact person Date Approval for in-place closure has been granted by the Local Health Department. Health Dept. Phone# Contact person Date Substance to be used to fill tanks: TANK REMOVER Name Russell J. Hicks Cert. # TR0404 Exp. Date 10/16/24 Company Push Drilling, LLC Phone # 801-928-0101 Address 852 Chelsea Dr.City Bountiful State UT Zip 84010 SOIL/GROUNDWATER SAMPLER Name Russell J. Hicks Cert. # GS1288 Exp. Date 2/15/26 Company Push Drilling, LLC Phone # 801-928-0101 Address 852 Chelsea Dr.City Bountiful State UT Zip 84010 I I I I I I I I I I I I I I I ~ □ □ □ I I I □ □ I I I □ I I I □ I I I 3 SITE ASSESSMENT A site assessment must be performed for all UST closures and change-in-service. Site assessments must be performed as outlined in 40 CFR 280.72 and R311-205 (U.A.C.). If contamination is suspected, additional samples must be collected at the location where contamination is most likely to be present. If groundwater is encountered, a soil sample must be collected, in the unsaturated zone, in addition to each groundwater sample. Soil and groundwater samples must be analyzed for the compounds shown in the following table, using appropriate lab methods. Substance or Product Type Contaminant Compounds to be Analyzed for Each Substance or Product Type ANALYTICAL METHODS1 Soil, Groundwater or Surface Water Gasoline Total Petroleum Hydrocarbons (purgeable TPH as gasoline range organics C6 - C10) EPA 8015 or EPA 8260 Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene, (BTEXN) and MTBE EPA 8021 or EPA 8260 Diesel Total Petroleum Hydrocarbons (extractable TPH as diesel range organics C10 – C28) EPA 8015 Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene (BTEXN) EPA 8021 or EPA 8260 Used Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene (BTEXN) & MTBE; and Halogenated Volatile Organic Compounds (VOX) EPA 8021 or EPA 8260 New Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Other Type of analyses will be based upon the substance or product stored, and as approved by the DERR Division Director Method will be based upon the substance or product type Unknown Total Petroleum Hydrocarbons (purgeable TPH as gasoline range organics C6 - C10) EPA 8015 or EPA 8260 Total Petroleum Hydrocarbons (extractable TPH as diesel range organics C10 – C28) EPA 8015 Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene (BTEXN) and MTBE; and Halogenated Volatile Organic Compounds (VOX) EPA 8021 or EPA 8260 1 The following modifications to these certified methods are considered acceptable by the DERR Division Director: Dual column confirmation may not be required for TPH and BTEXN/MTBE analysis. A micro-extraction or scale-down technique may be used for aqueous samples, but only for the determination of extractable TPH as diesel range organics (C10 – C28). Hexane may be used as an extraction solvent. *Silica Gel Treatment (SGT) may be used in the determination of Total Recoverable Petroleum Hydrocarbons. NOTE: The sample preparation method and any modification(s) to a certified method must be reported by the laboratory. • • • • 4 CONTAMINATED MATERIALS MUST BE DISPOSED AT AN ACCEPTABLE FACILITY: All materials generated from UST closures must be managed and disposed in a manner that does not place those materials in direct contact with the environment. On-site stockpiling of contaminated soils may be required prior to any soil management activities. Any person providing remedial assistance for a fee, including aeration and over-excavation (of more than 50 yd 3), must be a Certified UST Consultant. Contaminated soils generated as part of tank removal are to be disposed at the following facility: ET Technologies Address 6030 W. California Ave.City Salt Lake City State UT Zip 84104 Contact person Ted Sonnenburg Phone 801-973-2065 Complete the Facility Site Plat and Sample Information Table on pages 4 and 5 to provide site assessment information. CONTAMINATION INFORMATION If contamination at the facility is suspected or confirmed, the information must be reported to the DERR Division Director at (801) 536- 4100 within 24 hours. The Division of Water Quality must be notified at (801) 536-4300 if Free Product is encountered or if surface water has been impacted. If contamination is confirmed, any person assisting in the remediation process for a fee must be a Certified UST Consultant. SAMPLE INFORMATION TABLE Complete table for all samples to be taken for closure. 1 Soil (SS), Groundwater (GW), or Unified Soil Classification (USC). 2 Approx. depth in feet below grade. The required minimum site assessment samples must be taken at 0-2 feet below the backfill/native soil interface.3 Contaminant compounds to be analyzed for each sample (from table on p. 3). 4 Appropriate analysis methods for contaminant compound(s) in each sample (from table on p. 3). Sample # Substance stored in tank Sample type1 Depth2 Compounds3 Analysis method(s)4 SS-1 Gas SS 3-5' MBTEXN, TPH-GRO 8260B SS-2 Gas SS 3-5' Same Same USC-1 USC 3-5' Soil Class USC Facility Site Plat (Closure Plan) The site plat must be drawn to an appropriate identified scale. It must show planned sampling locations, substances stored in tanks, and other relevant information. Tank and sample identification numbers must be consistent with the information given on pages 1 anl 4 of the Closure Plan. Lee's Round-Up No. 1 1531 N. State Lehi, UT 84043 1500 North I Facility ID: 1000723 I Drawn By: R. Hicks X = Sample locations (SS-#, WS-#, USC-#) •=Monitoring Wells (MW-#) O= Soil boring (SB-#), or Geoprobe Boring (GP-#) a = Water Wells ( domestic, livestock, etc.) Slope of Surface Topography: (N,NW,W,SW,S,SE,E,NE) Land Use At Site: _Residential _Commercial _Industrial Surrounding Land: _Residential _Commercial _Industrial North ~ 5 Scale: 1"= 40 Feet I Date: 3-4-24 Site Plat Must Indicate Approximate Locations of: -Current & former tanks, piping & dispensers -Location of all samples to be taken -Buildings, fences, & property boundaries -Utility conduits (sewers, gas, water, storm drains, electrical, etc.) Approximate depth to groundwater in the vicinity of the tanks:~ 12feet. Regional groundwater flow direction: S State Certified Laboratory to be used : Chemtech-Ford Laboratories I City Sandy State I Zip 84070 Address 9632 S. 500 W. UT Contact Person Mark Broadhead Phone 801-262-7299 Please explain any unusual or extenuating circumstances expected regarding the site assessment or closure: Replacing reJ;!ular unleaded line and rubber boots between dispenser pumps 5/6 and 7/8. I certify under penalty of law that I am the owner/operator of the tank(s) referenced above and that I am familiar with the information on this form and that it is true, accurate and complete, and further, that the procedures described herein will be followed during tank closure. Signature of tank owner Full Name of tank owner 6