Loading...
HomeMy WebLinkAboutDERR-2024-005461 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-130-24 March 28, 2024 Sara Gallien Walmart, Inc. 2101 Southeast Simple Savings Drive Bentonville, Arkansas 72716 Re: Notice of Approval to Remove Delivery Prohibition Tag Walmart Supercenter Fueling Station #5270 Located at 585 North State Street, Lindon, Utah Facility Identification No. 1000995 Dear Ms. Gallien: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to issue the attached certificate of compliance for the 20,000-gallon regular, 12,000-gallon regular, 8,000-gallon premium, and 10,000-gallon diesel tanks at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(6). Please remove and discard any tags that were attached to the fill for these tanks during installation. If you have additional questions, please contact the DERR project manager, identified on the red tag, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/LP/ss Enclosure: Certificate of Compliance cc:Eric Edwards, Executive Director, Utah County Health Department SARA GALLIEN WALMART INC. 2024 UST CERTIFICATE OF COMPLIANCE ISSUED TO: LOCATION OF TANKS: WALMART SUPERCENTER FUELING STATION #5270 585 NORTH STATE STREET 2101 SE SIMPLE SAVINGS DR BENTONVILLE, AR 72716 LINDON UT 84042 Facility ID: 1000995 Tank# Capacity Substance Desc Compliance Financial Assurance Mechanism 1 2a 2b 3 20000 12000 8000 10000 Gasoline Gasoline Gasoline Diesel Yes PST Fund Yes PST Fund Yes PST Fund Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY Underground Storage Tank Inspection Verification Form Owner Name: WALMART INC. Owner Address: 2101 SE SIMPLE SAVINGS DR BENTONVILLE, AR 72716 Operator A: SUZANNE NEVES/ (435) 630-0320 / 1/19/2027 Facility ID: 1000995 Facility Name: WALMART SUPERCENTER FUELING STATION # Street Address: 585 NORTH STATE STREET LINDON, UT 84042 Operator B: CAROLYN AGNITA JONES/ (270) 922-9381 / 1/19/2027 Owner Email: Sara.Gallien@walmart.com UTM Coordinates X/Y: 437849 / 4466690 -----------------------------------------------------Disp ID/Alt Substance UDC Pipe Flex Loe Install Date UDC Install Date Fire Sat UDC Test Disp Flex CP ID Valve Present Test 1 -1/2 Gas/Diesel Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 2-3/4 Gas/Diesel Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 3-5/6 Gasoline Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 4-7/8 Gasoline Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 5 -9/10 Gasoline Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 6 -11/12 Gasoline Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 7 -13/14 Gas/Diesel Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex 8 -15/16 Gas/Diesel Yes Direct Flex Piping in 12/12/2023 12/12/2023 Yes No 12/14/2023 Sump no Steel Flex -----------------------------------------------------Tank ID/Alt ID: 1 / 1 EGen/AST/Stat No/ No/ No Pipe Material-Mod: Flexible Plastic -Double-Walled Siphon/Compart: No/ No PW/Stagel: Yes Tank Status: Currently In Use Two point Installed/Cap/Loe: 9/11/2023 / 20000 / Substance Stored: Gasoline/ Regular Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root I TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 3/14/2024 L TT Test: 3/14/2024 LLD Test: 03/14/2024 Tank ID/Alt ID: 2 / 2a Siphon/Compart: No/ Yes EGen/AST/Stat No/ No/ No Tank Status: Currently In Use Installed/Cap/Loe: 9/11/2023 / 12000 I Substance Stored: Gasoline/ Regular PW/Stagel: Yes Two point Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled ATG: Veeder Root I TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 3/14/2024 L TT Test: 3/14/2024 LLD Test: 03/14/2024 Tank ID/Alt ID: 3 / 2b EGen/AST/Stat No/ No/ No Siphon/Compart: No/ Yes PW/Stagel: Yes Tank Status: Currently In Use Two point Installed/Cap/Loe: 9/11/2023 / 8000 / Pipe Type/STP Cont: Pressurized / No STP Flex Connectors: Steel Flex in Sump LLD Model: Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Automatic shutoff/ No PST Fund/Other Type: Yes/ Tank/Pipe Rel Det: Interstitial DW / L TT/ ALD STP Sump Test: 12/14/2023 Spill Bk Test: Overfill Test: 3/14/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized / No STP Flex Connectors: Steel Flex in Sump LLD Model: Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Automatic shutoff/ No PST Fund/Other Type: No / Tank/Pipe Rel Det: Interstitial DW / L TT/ ALD STP Sump Test: 12/14/2023 Spill Bk Test: Overfill Test: 3/14/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized / No STP Flex Connectors: Steel Flex in Sump LLD Model: Substance Stored: Gasoline/ Premium Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket/ Automatic shutoff/ No Tank Material-Mod: Fiberglass Reinforced Plastic -Double-Walled PST Fund/Other Type: No/ 3/25/2024 Page 1 of 2 ATG: Veeder Root I TLS-450 Interstitial Monitor ATG Specs: / / Liquid Status ATG Test: 3/14/2024 L TT Test: 3/14/2024 Tank ID/Alt ID: 4 / 3 Siphon/Compart: No/ No LLD Test: 03/14/2024 EGen/AST/Stat No/ No/ No PW/Stagel: Yes Tank Status: Currently In Use Installed/Cap/Loe: 9/11/2023 / 10000 I Substance Stored: Diesel/ Diesel #1 Tank Material-Mod: Fiberglass Reinforced Plastic - ATG: Veeder Root I ATG Specs: / / ATG Test: 3/14/2024 Two point L TT Test: 3/14/2024 LLD Test: 03/14/2024 3/25/2024 Page 2 of 2 Tank/Pipe Rel Det: Interstitial DWI L TT/ ALD STP Sump Test: 12/14/2023 Spill Bk Test: Overfill Test: 3/14/2024 CP Tank Test: CP Pipe Test: Pipe Material-Mod: Flexible Plastic -Double-Walled Pipe Type/STP Cont: Pressurized / No STP Flex Connectors: Steel Flex in Sump LLD Model: Spill/Overfill/Sm deliv: 5 gal. Double Walled Spill Bucket / Automatic shutoff/ No PST Fund/Other Type: No / Tank/Pipe Rel Det: Interstitial DWI L TT/ ALD STP Sump Test: 12/14/2023 Spill Bk Test: Overfill Test: 3/14/2024 CP Tank Test: CP Pipe Test: