Loading...
HomeMy WebLinkAboutDAQ-2025-002012 DAQE-GN117060001-25 {{$d1 }} Mark Hogan Utah Army National Guard 12953 South Minuteman Drive G9 – CFMO – ERM Draper, UT 84020 mark.a.hogan26.nfg@army.mil Dear Mr. Hogan: RE: Revocation of Approval Order DAQE-845-97 dated August 29, 1997 Project Number: N117060001 The Utah Division of Air Quality received your request to revoke Approval Order (AO) DAQE-845-97, dated August 29, 1997, on April 1, 2025. The Utah Army National Guard has requested the above-referenced AO be revoked and replaced with a Small Source Exemption (SSE) under UAC R307-401-9. The DAQ has evaluated the request and found the source is eligible for an SSE. The DAQ has revoked the above-referenced AO effective as of the date of this letter. As authorized by the Utah Legislature, the fee for revoking an AO is the actual time spent by the review engineer and all other staff on the project. Payment should be sent to the DAQ upon receipt of the invoice. If you have any questions, please contact Katie Andersen, who can be reached at (385) 515-1748. Sincerely, {{$s }} Bryce C. Bird Director BCB:KA:jg cc: EPA Region 8 {{#d1=date1_es_:signer1:date:format(date, "mmmm d, yyyy")}} {{#s=Sig_es_:signer1:signature}} 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Tim Davis Interim Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director April 9, 2025 Utah Army National Guard Defense Depot - Ogden Emergency Generator Emissions Calculations NOx Emission Factor (lb/HP-hr)3.10E-02 [AP-42, Table 3.3-1, Diesel Fuel] CO Emission Factor (lb/HP-hr)6.68E-03 [AP-42, Table 3.3-1, Diesel Fuel] SOx Emission Factor (lb/HP-hr)2.05E-03 [AP-42, Table 3.3-1, Diesel Fuel] PM10 Emission Factor (lb/HP-hr)2.20E-03 [AP-42, Table 3.3-1, Diesel Fuel] TOC Emission Factor (lb/HP-hr)2.51E-03 [AP-42, Table 3.3-1, Diesel Fuel] Source Name Caterpillar Engine Location DDO Bay 1 Rating (kW)345 Rating (HP)463 Fuel Use (gal/hr)26.5 Annual Hours of Operation 30 Fuel Use (gal/yr)795 Tier Level N/A NOx Emissions (lb/hr)14.35 CO Emissions (lb/hr)3.09 SOx Emissions (lb/hr)0.95 PM10 Emissions (lb/hr)1.02 PM2.5 Emissions (lb/hr)1.02 VOC Emissions (lb/hr)1.16 NOx Emissions (tpy)0.215 CO Emissions (tpy)0.046 SOx Emissions (tpy)0.014 PM10 Emissions (tpy)0.015 PM2.5 Emissions (tpy)0.015 VOC Emissions (tpy)0.017 Notes: Emissions estimated using factors from AP-42 Table 3.3-1. Fuel Use estimated using data availab Diesel heat rating 0.1395 MMBtu/gal Fuel use 3.7 MMBtu/hr Fuel use 110.9 MMBtu/yr HAP Emissions Pollutant (lb/MMbtu) (lb/hr) (lb/year) Acenaphthene 1.42E-06 5.25E-06 1.57E-04 Acenaphthylene 5.06E-06 1.87E-05 5.61E-04 Acetaldehyde 7.67E-04 2.84E-03 8.51E-02 Acrolein 9.25E-05 3.42E-04 1.03E-02 Anthracene 1.87E-06 6.91E-06 2.07E-04 Benz[a]anthracene 1.68E-06 6.21E-06 1.86E-04 Benzene 9.33E-04 3.45E-03 1.03E-01 Benzo[b]fluoranthene 9.91E-08 3.66E-07 1.10E-05 Benzo[k]fluoranthene 1.55E-07 5.73E-07 1.72E-05 Benzo(g,h,l)perylene 4.89E-07 1.81E-06 5.42E-05 Benzo[a]pyrene 1.88E-07 6.95E-07 2.08E-05 1,3-Butadiene 3.91E-05 1.45E-04 4.34E-03 Dibenz[a,h]anthracene 5.83E-07 2.16E-06 6.47E-05 Fluoranthene 7.61E-06 2.81E-05 8.44E-04 Fluorene 2.92E-05 1.08E-04 3.24E-03 Formaldehyde 1.18E-03 4.36E-03 1.31E-01 Indeno[1,2,3-c,d]pyrene 3.75E-07 1.39E-06 4.16E-05 Naphthalene 8.48E-05 3.13E-04 9.40E-03 Phenanthrene 2.94E-05 1.09E-04 3.26E-03 Pyrene 4.78E-06 1.77E-05 5.30E-04 Toluene 4.09E-04 1.51E-03 4.54E-02 Xylenes - Mixed isomer 2.85E-04 1.05E-03 3.16E-02 Total 1.43E-02 4.30E-01 Notes: (1) HAP emission factors taken from AP-42 Section 3.3, Tables 3.3-2 (2) HAP emission factors taken from Air Emissions Guide for Air Force Stationary Sources. Table CO2 73.25 kg/MMBtu 40 CFR 98.33 Tab CH4 3.00E-03 kg/MMBtu 40 CFR 98.33 Ta N2O 6.00E-04 kg/MMBtu 40 CFR 98.33 Tab CO2 Emissions (tpy) (tpy) (tpy) (tpy) 4.48E-03 3.67E-04 7.33E-05 3.55E-02 Notes: (1) CO2 emission factors and calculations from 40 CFR 98.33 0.43 3-7 HAP Emission Factors for Stationary Compression Ignition ICOM Engines Response Summary: The form below will collect the information to start the revocation process. Please fill out the information and a NSR Engineer will be contacting you with any follow up requirements. Q2. Company/Owner Information: Owner Name:Utah Army National Guard Address 12953 Minuteman Drive City Draper State UT Zip 84020 Q4. Contact Information: Contact Name:Mark Hogan Contact email:mark.a.hogan26.nfg@army.mil Contact phone 801-432-4450 Q3. Permit Information: Site Name:Defense Depot Ogden - Joint Language Training Center Site ID:11706 Permit ID: Ex DAQE- 111110001-21 DAQE-845-97 Q9. Is the AO revocation subject to the Oil and Gas PBR Registration? PBR Requirements No Q5. Please provide an explanation for the request to revoke your permit We are replacing this AO with a Small Source Exemption Registration. Q6. The undersigned acknowledges they are the responsible party to provide DAQ with this information and authorize DAQ to bill the fee for revoking an AO. As authorized by Utah Legislature, the fee is the time spent by the Permitting staff. [Click here] Embedded Data: N/A