HomeMy WebLinkAboutDDW-2025-003488Annual Drinking
Water Quality Report
Bothwell Town Water System (UTAH02003)
-Calendar Year 2024-
(completed April 3, 2025)
10100 West 11600 North
Tremonton, Utah 84337
We are pleased to present to you this year's Annual Drinking Water Quality Report for the Bothwell Town Water System. This report is designed to inform you about the quality of the water
and services we deliver to you every day. Our goal is to provide you with a safe and dependable supply of drinking water. We want you to understand the efforts we make to continually
improve the water treatment process and protect our water resources. We are committed to ensuring the quality of your water. Our water source is ground water collected from several wells
in the Bothwell Pocket. Those wells consist of the following;
WELL 1 EAST (source ID WS002) owned and operated by the Bothwell Town Water System
WELL 2 WEST (source ID WS003) owned and operated by the Bothwell Town Water System
Water purchased from the Bear River Water Conservancy District (UTAH02066). This source will be noted as BRWCD in the contamination constituent level testing summary tables when applicable.
NEWMAN WELL (source ID WS001)
BACK UP WELL (source ID WS002)
Currently, about 50% of the water used in the Bothwell Town Water System comes from the BRWCD source during the months that this source is turned into the system. We draw water from
the BRWCD generally from mid-May to the end of September.
We are pleased to report that our drinking water meets all federal and state requirements. Water sampling and testing results are given in the last sections of this report.
QUESTIONS
This report shows our water quality and what it means to our community. If you have any questions about this report or concerning your water utility, please contact Joe Summers, 11100
W 11200 N, Tremonton, Utah, (435) 230-0034, or any of the board members listed at the end of this report.
PLEASE ATTEND
Our water system is community owned and managed by a community appointed board. We want you to be informed about your water utility. If you want to learn more, please attend any of our
regularly scheduled meetings. They are held on a monthly basis, usually on the fourth Wednesday of each month at 7PM. As we have no city offices the meetings are scheduled at the different
board member homes. Please contact Joe Summers (contact information given in the preceding section), or any board member, for the location of the monthly meeting for the month you wish
to attend. You can contact the board members at any time, it is not necessary to wait for a board meeting.
LEAD AND COPPER
Corrosion of pipes, plumbing fittings and fixtures may cause metals, including lead and copper to enter drinking water. To assess contamination potential of lead and copper the Bothwell
Town Water System conducts tap sampling at 5 different locations throughout the system every 3 years. Water samples are tested by the Chemtech-Ford test laboratory in Sandy, Utah.
Those results are shown in the test results section of this report.
LEAD SERVICE LINE INVENTORY INFORMATION
With the assistance of Sunset Engineering, Logan, UT, who has been contracted by the state to provide required documentation, we have completed an initial service line inventory have
found no lead or galvanized pipe within the Bothwell Town Water System distribution lines.
SOURCE PROTECTION PLAN (updated and provided to the State September 2022)
The Drinking Water Source Protection Plans for the Bothwell Town Water System are available for your review. Plans were submitted to the State in 2022 and we received approval of the
plans in March of 2023. They contain information about source protection zones, potential contamination sources and management strategies to protect the wells that provide our drinking
water. Potential contamination sources common in our protection areas are erosion and leaching of natural deposits in the earth, runoff from fertilizer, leaching from septic tanks,
by-products of drinking water disinfection, and corrosion of household plumbing systems. We have developed management strategies to protect our sources from contamination. Please contact
us if you have questions or concerns about our source protection plans, or if you observe conditions, you feel might result in contamination of our water.
CROSS CONNECTION CONTROL
There are many connections to our water distribution system. When connections are properly installed and maintained, the concerns are very minimal. However, unapproved and improper
piping changes or connections can adversely affect not only the availability, but also the quality, of the water. A cross connection may allow polluted water or even chemicals to mingle
into the water supply system when not properly protected. This not only compromises the water quality but can also affect your health. So, what can you do? Do not make or allow improper
connections at your homes or farms. Even that unprotected garden hose lying in the puddle next to the driveway is a possible cross connection. The unprotected lawn sprinkler system
after you have fertilized or sprayed is also a cross connection concern. For example, if the valve on the hose or the sprinkler system were to be left open and the main line were to
drain out due to a break then a vacuum would form syphoning whatever is at the end of the hose or sprinkler system to be sucked into your home and on into the main line. When the cross
connection is allowed to exist at your home it will affect you and your family first. If you’d like to learn more about helping to protect the quality of our water, call us for further
information about ways you can help.
IDENTIFIED VIOLATIONS or EXCEEDANCES
None currently identified.
TESTING AND RESULTS
The Bothwell Town Water System routinely monitors for constituents in our drinking water in accordance with the Federal and Utah State laws and testing schedules. The current testing
laboratories used are Chemtech-Ford Laboratories in Sandy, Utah, and the Brigham City water testing facility. The following table shows the results of our monitoring for the period of
January 1st to December 31st, 2024 or the most recent sample data. All drinking water, including bottled drinking water, may be reasonably expected to contain at least small amounts
of some constituents. It's important to remember that the presence of these constituents does not necessarily pose a health risk.
In addition to the regularly scheduled testing for 2024, the water system, at the request of the Utah Department of Environmental Quality, provided samples to Pace Analytical Services,
LLC of Peoria, Illinois to test for PFAS (chemical contaminants related to manufacturing activities). The report, from Pace and the State of Utah, indicates none of these chemicals
were detected in our drinking water.
CONSTITUENT TABLE DEFINITIONS
In the following tables are listed the testing and any contaminants that were detected by our regular testing. None were detected in levels that violate water quality standards.
In the following table you will find many terms and abbreviations you might not be familiar with. To help you better understand these terms we have provided the following definitions
Non-Detects (ND) - Laboratory analysis indicates that the constituent is not present.
ND/Low - High - For water systems that have multiple sources of water, the Utah Division of Drinking Water has given water systems the option of listing the test results of the constituents
in one table, instead of multiple tables. To accomplish this, the lowest and highest values detected in the multiple sources are recorded in the same space in the report table.
Parts per million (ppm) or Milligrams per liter (mg/l) - One part per million corresponds to one minute in two years or a single penny in $10,000.
Parts per billion (ppb) or Micrograms per liter (ug/l) - One part per billion corresponds to one minute in 2,000 years, or a single penny in $10,000,000.
Parts per trillion (ppt) or Nanograms per liter (nanograms/l) - One part per trillion corresponds to one minute in 2,000,000 years, or a single penny in $10,000,000,000.
Parts per quadrillion (ppq) or Picograms per liter (picograms/l) - One part per quadrillion corresponds to one minute in 2,000,000,000 years or one penny in $10,000,000,000,000.
Picocuries per liter (pCi/L) - Picocuries per liter is a measure of the radioactivity in water.
Millirems per year (mrem/yr) - Measure of radiation absorbed by the body.
Million Fibers per Liter (MFL) - Million fibers per liter is a measure of the presence of asbestos fibers that are longer than 10 micrometers.
Nephelometric Turbidity Unit (NTU) - Nephelometric turbidity unit is a measure of the clarity of water. Turbidity in excess of 5 NTU is just noticeable to the average person.
Action Level (AL) - The concentration of a contaminant which, if exceeded, triggers treatment or other
Maximum Contaminant Level (MCL) - The “Maximum Allowed” (MCL) is the highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible
using the best available treatment technology.
Maximum Contaminant Level Goal (MCLG) - The “Goal”(MCLG) is the level of a contaminant in drinking water below which there is no known or expected risk to health. MCLGs allow for a
margin of safety.
Date- Because of required sampling time frames i.e. yearly, 3 years, 4 years and 6 years, sampling dates may seem out-dated.
Waivers (W)- Because some chemicals are not used or stored in areas around drinking water sources, some water systems have been given waivers that exempt them from having to take certain
chemical samples, these waivers are also tied to Drinking Water Source Protection Plans.
NONE OF THE CONSTITUENTS IN THE FOLLOWING TABLE TESTED AT LEVELS VIOLATING WATER QUALITY REQUIREMENTS.
CONSTITUENT TABLE - TEST RESULTS – REGULATED CONTAMINANTS CONTAMINANT VIOL.
Y/N LEVEL DETECTED UNIT MEAS. MCLG MCL DATE SAMPLED LIKELY SOURCE OF CONTAMINATION MICROBIOLOGICAL CONTAMINANTS Total Coliform Bacteria N ND N/A 0 5 2024
(monthly) Naturally present in the environment *Presence of coliform bacteria in 5% of monthly samples Fecal coliform and E.coli N ND N/A 0 None** 2024
(monthly) Human and animal fecal waste **If a routine sample and repeat sample are total coliform positive, and one is also fecal coliform or E. coli positive Turbidity
for Ground Water N 0.02 NTU N/A 0.3 2020 Soil Runoff RADIOLOGICAL CONTAMINANTS Alpha emitters N 3.3-3.7 pCi/1 0 15 2022 Erosion of natural deposits Combined radium (226,228) N 1.1 pCi/1 0 5 2020 Erosion
of natural deposits Radium-226 N 0.4 pCi/1 0 5 2020 Erosion of natural deposits Radium-228 N 0.58 pCi/1 0 5 2022 Erosion of natural deposits INORGANIC CONTAMINANTS Arsenic N 0.9 ppb 0 10 2020 Erosion
of natural deposits; runoff from orchards; runoff from glass and electronics production wastes Barium N 0.064 ppm 2,000 2,000 2020 Discharge of drilling wastes; discharge from metal
refineries; erosion of natural deposits Copper
90% results
# of sites that exceed the AL N a.0.018
b. 0 ppm 1,300 AL=1.3 2024 Corrosion of household plumbing systems; erosion of natural deposits Fluoride N 0.2 ppm 4 4 2020 Erosion of natural deposits; water additive which promotes
strong teeth; discharge from fertilizer and aluminum factories Lead
90% results
# of sites that exceed the AL N a. 0
b. 0 ppb 0 AL=15 2024
Corrosion of household plumbing systems, erosion of natural deposits Nitrate (as Nitrogen) N 1.324-2.395 ppm 10 10 2024 Runoff from fertilizer use; leaching from septic tanks, sewage;
erosion of natural deposits Selenium N 5.4 ppb 50 50 2020 Discharge from petroleum and metal refineries; erosion of natural deposits; discharge from mines Sodium N 129 ppm 500 None
set by EPA 2020 Erosion of natural deposits; discharge from refineries and factories; runoff from landfills. Sulfate N 77 ppm 1,000* 1,000* 2020 Erosion of natural deposits;
discharge from refineries and factories; runoff from landfills, runoff from cropland Total Dissolved Solids (TDS) N 920 ppm 2,000** 2,000** 2022
(BRWCD) Erosion of natural deposits *If the sulfate level of a public water system is greater than 500 ppm, the supplier must satisfactorily demonstrate that: a) no better water is
available, and b) the water shall not be available for human consumption from commercial establishments. In no case shall water having a level above 1000 ppm be used.
**If TDS is greater than 1000 ppm the supplier shall demonstrate to the Utah Drinking Water Board that no better water is available. The Board shall not allow the use of an inferior
source of water if a better source is available.
BOTHWELL TOWN WATER BOARD
Byron Nelson
Joe Summers
Allan Thompson
Chad Coombs
BOTHWELL TOWN WATER SYSEM CERTIFIED OPERATOR
Paul C. Fulgham (Certification #: 88129)
-CCR 2023 COMPLIANCE LETTER-
Bothwell City Water System
10100 West 11600 North
Tremonton, Utah 84337
April 7, 2025
CCR Compliance
Division of Drinking Water
P.O. Box 144830
Salt Lake City, Utah 84114-4830
Email: ddwreports@utah.gov
Phone: 801-536-4196
Fax: 801-536-4211
Subject: Consumer Confidence Report for Bothwell Town Water System, Water system No. UTAH02003
Enclosed is a copy of the (Bothwell Town Water System) Consumer Confidence Report. It contains the water quality information for our water system for the calendar year 2024 or the most
recent sample data.
We have delivered this report to our customers by:
Posted a notice of the availability of the report on our water bill and sending a copy to those that request a copy and allowing inspection of the report at the home office of the water
system financial officer or any of the board members.
When new meters are allocated, this report and cross connection control requirements are reviewed with the new customer.
If you have any questions, please contact me at (435) 230-0034.
Sincerely,
Joseph F. Summers, President
Bothwell Water Board
Bothwell Town Water System
Other Water Board Members,
Byron Nelson (Financial Officer), Allan Thompson (Administrative Contact), Chad Coombs
Certified Operator,
Paul C. Fulgham (Certification #: 88129)