Loading...
HomeMy WebLinkAboutDERR-2024-005548IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION OVERFILL OPERABILITY PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 4/1/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 3/12/2024 Order Number: 2365037 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #23099, MKT 1606 2102 S STATE ST State ID 4001035 SOUTH SALT LAKE, UT 84115 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 7-ELEVEN #23099, MKT 1606 2102 S STATE ST State ID 4001035 SOUTH SALT LAKE UT 84115 23099 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 03/12/2024 REGULAR PREMIUM Vaporless LD- 2000 Vaporless LD- 2000 Vaporless LD- 2000LD2000LD2000LD2000 36 36 170 3 20 4 30 30 170 3 20 4 38 38 110 2 20 3 UT151 David Mathie NW1-2365037 Low Sulfur Diesel TTNK 4:1 TTNK5:1 TTNK6:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2365037 Date:3/12/2024 Site Name/ID:7-ELEVEN #23099, MKT 1606 Address:2102 S STATE ST State ID 4001035 City:SOUTH SALT LAKE State:UT Zip:84115 How Inspected: Line Test NFPA 30A PEI RP1200 Other STP PRESSURE Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #23099, MKT 1606 7-ELEVEN, INC. 2102 S STATE ST State ID 4001035 SOUTH SALT LAKE UT 84115 4001035 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 03/12/2024 4 5 6 RUL PUL DSL VR 350 VR350 VR350 19930 8039 11897 119.38 119.38 119.38 UT151 David Mathie 2102 S STATE ST State ID 4001035 7-ELEVEN #23099, MKT 1606 2102 S STATE ST State ID 4001035, SOUTH SALT LAKE, UT 8411523099 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 03/12/2024 ANNULAR ANNULAR SB FILL STP SB FILL STP SB FILL RUL PUL/DSL RUL RUL PUL PUL DSL UT151 David Mathie 2102 S STATE ST State ID 4001035 7-ELEVEN #23099, MKT 1606 2102 S STATE ST State ID 4001035, SOUTH SALT LAKE, UT 8411523099 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 03/12/2024 STP UDC UDC UDC UDC UDC UDC DSL 1/2 3/4 5/6 7/8 9/10 11/12 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN #23099, MKT 1606 Name :TANKNOLOGY INC. Address :2102 S STATE ST State ID 4001035 SOUTH SALT LAKE, UT 84115 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-487-6104 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?N0 Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK 4 REGULAR 19930 11385 8545 12:54 2.00 2.00 2.00 2.00 1.99 1.99 1.89 Pass TNK5 PREMIUM 8039 3555 4484 13:03 2.00 1.99 1.98 1.97 1.96 1.95 1.78 Pass Total 27969 14940 13029 All Comments: Tester :David Mathie Test Date :3/12/2024 Signature :Work Order :2365037 WO: 2365037 PVVC tested ==>EASTRUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.21 Pass Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -3.28 Fail PVVC tested ==>EASTRUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.68 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.12 Pass PVVC tested ==>CENTERPUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 9 0.0191 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.38 Pass Neg Leak Rate (CFH)0.21 20 0.0424 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.48 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0318 Total -ve LR: 0.0742 Test Date 3/12/2024 Technician Name David Mathie WO #2365037 Facility Name / Loc #7-ELEVEN #23099, MKT 1606 23099 Street 2102 S STATE ST State ID 4001035 City, St, Zip SOUTH SALT LAKE, UT 84115 Pressure Vacuum Vent Cap Test Form TP-201.1E 7-ELEVEN #23099, MKT 1606 2102 S STATE ST State ID 4001035 SOUTH SALT LAKE , UT 84115 23099 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 800-800-4633 03/12/2024 RUL 4 19930 119.375 OPW PUL 5 8039 119.375 OPW DSL 6 11897 119.375 OPW UT151 David Mathie P.O. BOX 711 DALLAS, TX 75221 76 184.375 19930 106.375 19930 18802 94.3 Site ID/ Name: Address: 23099 7-ELEVEN #23099, MKT 1606 NW1-2365037 03/12/2024 2102 S STATE ST State ID 4001035, SOUTH SALT LAKE, UT 84115 Tank ID:TNK 4(REGULAR) 75.5 184.5 8039 107 8039 7579 94.3 Site ID/ Name: Address: 23099 7-ELEVEN #23099, MKT 1606 NW1-2365037 03/12/2024 2102 S STATE ST State ID 4001035, SOUTH SALT LAKE, UT 84115 Tank ID:TNK5(PREMIUM) 74.25 183 11897 106.75 11897 11272 94.7 Site ID/ Name: Address: 23099 7-ELEVEN #23099, MKT 1606 NW1-2365037 03/12/2024 2102 S STATE ST State ID 4001035, SOUTH SALT LAKE, UT 84115 Tank ID:TNK6(Low Sulfur Diesel) Tank ID: Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2365037 Site ID / Name:23099 / 7-ELEVEN #23099, MKT 1606 Address:2102 S STATE ST State ID 4001035 City:SOUTH SALT LAKE State:UT Zip:84115 W.O.# NW1-2365037 +AAE- I10100 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 MAR 12, 2024 1:49 PM SOFTWARE REVISION LEVEL VERSION 333.03 SOFTWARE+ACM- 346333-100-D CREATED - 13.02.12.10.26 S-MODULE+ACM- 330160-162-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV +AAMAAQ- I11B00 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 SERVICE NOTICE SESSION REPORT START TIME END TIME MAR 12, 2024 11:41 AM MAR 12, 2024 1:42 PM MAR 15, 2023 9:37 AM MAR 15, 2023 11:32 AM APR 11, 2022 11:29 AM APR 11, 2022 12:53 PM APR 19, 2021 12:00 PM APR 19, 2021 1:51 PM MAY 8, 2020 9:01 AM MAY 8, 2020 11:02 AM +AAMAAQ- I20100 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 4 RUL 11336 11386 8594 64.83 0.00 53.57 5 PUL 3537 3548 4350 53.82 0.00 55.32 6 DSL 7042 7055 4855 68.02 0.00 55.72 +AAMAAQ- I30100 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 RUL ANNULAR SENSOR NORMAL 2 PUL-DSL ANNULAR SENSOR NORMAL 3 RUL STP SUMP SENSOR NORMAL 4 RUL SPILL BUCKET SENSOR NORMAL 5 PUL STP SUMP SENSOR NORMAL 6 PUL SPILL BUCKET SENSOR NORMAL 7 DSL STP SUMP SENSOR NORMAL 8 DSL SPILL BUCKET SENSOR NORMAL 9 DISPENSER 1-2 SENSOR NORMAL 10 DISPENSER 3-4 SENSOR NORMAL 11 DISPENSER 5-6 SENSOR NORMAL 12 DISPENSER 7-8 SENSOR NORMAL 13 DISPENSER 9-10 SENSOR NORMAL 14 DISPENSER 11-12 SENSOR NORMAL +AAMAAQ- I30200 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 RUL ANNULAR MAR 12, 2024 12:11 PM FUEL ALARM MAR 15, 2023 10:15 AM FUEL ALARM APR 11, 2022 12:03 PM FUEL ALARM 2 PUL-DSL ANNULAR MAR 12, 2024 12:14 PM FUEL ALARM MAR 15, 2023 10:20 AM FUEL ALARM APR 11, 2022 12:07 PM FUEL ALARM 3 RUL STP SUMP MAR 12, 2024 12:58 PM FUEL ALARM MAR 15, 2023 10:27 AM FUEL ALARM APR 11, 2022 12:33 PM FUEL ALARM 4 RUL SPILL BUCKET MAR 12, 2024 12:01 PM FUEL ALARM MAR 15, 2023 11:10 AM FUEL ALARM APR 11, 2022 12:36 PM FUEL ALARM 5 PUL STP SUMP MAR 12, 2024 1:05 PM FUEL ALARM MAR 15, 2023 10:30 AM FUEL ALARM APR 11, 2022 12:25 PM FUEL ALARM 6 PUL SPILL BUCKET MAR 12, 2024 12:04 PM FUEL ALARM MAR 15, 2023 10:56 AM FUEL ALARM APR 11, 2022 12:27 PM FUEL ALARM 7 DSL STP SUMP MAR 12, 2024 1:08 PM FUEL ALARM MAR 15, 2023 10:33 AM FUEL ALARM APR 11, 2022 12:19 PM FUEL ALARM 8 DSL SPILL BUCKET MAR 12, 2024 12:07 PM FUEL ALARM MAR 15, 2023 10:48 AM FUEL ALARM APR 11, 2022 12:21 PM FUEL ALARM 9 DISPENSER 1-2 MAR 12, 2024 12:19 PM FUEL ALARM MAR 15, 2023 9:47 AM FUEL ALARM APR 11, 2022 11:41 AM FUEL ALARM 10 DISPENSER 3-4 MAR 12, 2024 12:19 PM FUEL ALARM MAR 15, 2023 9:47 AM FUEL ALARM APR 11, 2022 11:42 AM FUEL ALARM 11 DISPENSER 5-6 MAR 12, 2024 12:20 PM FUEL ALARM MAR 15, 2023 9:48 AM FUEL ALARM APR 11, 2022 11:42 AM FUEL ALARM 12 DISPENSER 7-8 MAR 12, 2024 12:20 PM FUEL ALARM MAR 15, 2023 9:48 AM FUEL ALARM APR 11, 2022 11:42 AM FUEL ALARM 13 DISPENSER 9-10 MAR 12, 2024 12:21 PM FUEL ALARM MAR 15, 2023 9:49 AM FUEL ALARM APR 11, 2022 11:43 AM FUEL ALARM 14 DISPENSER 11-12 MAR 12, 2024 12:21 PM FUEL ALARM MAR 15, 2023 9:49 AM FUEL ALARM APR 11, 2022 11:43 AM FUEL ALARM +AAMAAQ- IA0100 MAR 12, 2024 1:49 PM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 4 RUL MAG D004 126.00 131835 0684 TANK 5 PUL MAG D004 126.00 131831 0684 TANK 6 DSL MAG D004 126.00 131832 0684 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: PRODUCT CODE 1 OVERFILL LIMIT: 0 HIGH PRODUCT LIMIT: 0 LOW PRODUCT: 0 SUDDEN LOSS LIMIT: 99 LEAK LIMIT: 99 THERMAL COEFF: 0.000000 DELIVERY DELAY: 1 TANK FULL CAPACITY: 0 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 0.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 932 TANK 2 SETUP CONDITIONS PRODUCT: PRODUCT CODE 2 OVERFILL LIMIT: 0 HIGH PRODUCT LIMIT: 0 LOW PRODUCT: 0 SUDDEN LOSS LIMIT: 99 LEAK LIMIT: 99 THERMAL COEFF: 0.000000 DELIVERY DELAY: 1 TANK FULL CAPACITY: 0 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 0.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 933 TANK 3 SETUP CONDITIONS PRODUCT: PRODUCT CODE 3 OVERFILL LIMIT: 0 HIGH PRODUCT LIMIT: 0 LOW PRODUCT: 0 SUDDEN LOSS LIMIT: 99 LEAK LIMIT: 99 THERMAL COEFF: 0.000000 DELIVERY DELAY: 1 TANK FULL CAPACITY: 0 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 0.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I61100 MAR 12, 2024 1:49 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK FEB 12, 2013 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED +AAMAAQ- I70300 MAR 12, 2024 1:49 PM LIQUID TYPE SENSOR LOCATION TYPE 1 RUL ANNULAR TRI-STATE (SINGLE FLOAT) 2 PUL-DSL ANNULAR TRI-STATE (SINGLE FLOAT) 3 RUL STP SUMP TRI-STATE (SINGLE FLOAT) 4 RUL SPILL BUCKET NORMALLY CLOSED 5 PUL STP SUMP TRI-STATE (SINGLE FLOAT) 6 PUL SPILL BUCKET NORMALLY CLOSED 7 DSL STP SUMP TRI-STATE (SINGLE FLOAT) 8 DSL SPILL BUCKET NORMALLY CLOSED 9 DISPENSER 1-2 TRI-STATE (SINGLE FLOAT) 10 DISPENSER 3-4 TRI-STATE (SINGLE FLOAT) 11 DISPENSER 5-6 TRI-STATE (SINGLE FLOAT) 12 DISPENSER 7-8 TRI-STATE (SINGLE FLOAT) 13 DISPENSER 9-10 TRI-STATE (SINGLE FLOAT) 14 DISPENSER 11-12 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) +AAMAAQ- I10200 MAR 12, 2024 1:49 PM 164533 7-11 23099 2102 SO STATE ST SLC UT 84115 A0369066005001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163004 163109 2 4 PROBE / G.T. 162890 163293 3 INTERSTITIAL BD 201455 201443 4 INTERSTITIAL BD 201524 201907 5 UNUSED 9857638 9768857 6 UNUSED 9846851 9764296 7 UNUSED 9846123 9761470 8 UNUSED 9846917 9765764 9 UNUSED 9839314 9755528 10 UNUSED 9835652 9761958 11 UNUSED 9852307 9759555 12 UNUSED 9846483 9751367 13 UNUSED 9843659 9757908 14 UNUSED 9829211 9750744 15 UNUSED 9851336 9764339 16 UNUSED 9838586 9759110 COMM 1 ELEC DISP INT. 101086 101202 COMM 2 UNUSED 9849329 9766541 COMM 3 SERIAL SAT BD 483016 482334 COMM 4 UNUSED 9843395 9767721 COMM 5 RS485 SERIAL BD 68815 68919 COMM 6 MT COMM BOARD 411250 412203 +AAM-