HomeMy WebLinkAboutDERR-2024-005522pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Maverik #670 797 E 800 N Spanish Fork, UT 1000968 02/29/2024 1 Reg 1 VR PLLD 4 45 2 4 4 4 3 Prm VR PLLD 4 45 2 4 4 4 4 Dsl VR PLLD 4 45 2 4 4 4 5 Clr VR PLLD 4 45 2 4 4 4 Saxon Usher UT-420 pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-3 SPILL BUCKET INTEGRITY TESTING HYDROSTATIC TEST METHOD SINGLE AND DOUBLE-WALLED VACUUM TEST METHOD )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVSURFHGXUHLVWRWHVWWKHOHDNLQWHJULW\RIVLQJOHDQGGRXEOHZDOOHGVSLOOEXFNHWV6HH3(,536HFWLRQIRUK\GURVWDWLF WHVWPHWKRG6HFWLRQIRUVLQJOHZDOOHGYDFXXPWHVWPHWKRGDQG6HFWLRQIRUGRXEOHZDOOHGYDFXXPWHVWPHWKRG 7DQN1XPEHU 3URGXFW6WRUHG 6SLOO%XFNHW &DSDFLW\ 0DQXIDFWXUHU &RQVWUXFWLRQ6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 7HVW7\SH +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG 6SLOO%XFNHW7\SH 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU /LTXLGDQGGHEULV UHPRYHGIURP VSLOOEXFNHW" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9LVXDO,QVSHFWLRQ 1RFUDFNVORRVH SDUWVRUVHSDUD WLRQRIWKHEXFNHW IURPWKHILOOSLSH 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 7DQNULVHUFDS LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ ,VGUDLQYDOYH LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ 6WDUWLQJ/HYHO 7HVW6WDUW7LPH       (QGLQJ/HYHO 7HVW(QG7LPH 7HVW3HULRG /HYHO&KDQJH 3DVVIDLOFULWHULD0XVWSDVVYLVXDOLQVSHFWLRQ+\GURVWDWLF:DWHUOHYHOGURSRIOHVVWKDQLQFK9DFXXPVLQJOHZDOOHGRQO\ 0DLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ9DFXXPGRXEOHZDOOHGPDLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 MAVERIK #670 1000968 02/29/2024 1 Regular 1 5 Gal OPW 4 4 4 4 4 4 4 18" WC 0 Min 17.2" WC 5 Min 5 Min 0.8" WC 4 2 Regular 2 5 Gal OPW 4 4 4 4 4 4 4 17.5" WC 0 Min 16" WC 5 Min 5 Min 1.5" WC 4 3 Premium 5 Gal OPW 4 4 4 4 4 4 4 16" WC 0 Min 15.7" WC 5 Min 5 Min 0.3" WC 4 4 Diesel 5 Gal OPW 4 4 4 4 4 4 4 19" WC 0 Min 18.3" WC 5 Min 5 Min 0.7" WC 4 5 Clear 5 Gal OPW 4 4 4 4 4 4 4 20" WC 0 Min 18.9" WC 5 Min 5 Min 1.1" WC 4 4 Saxon Usher UT-420 PEI/RP1200-12 pei.org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´1RµRU/LQHLV´<HVµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 02/29/2024 1 Regular E VRTLS 450+ 13288 119.4" 4 4 4 4 4 100" 11959 89 4 4 4 4 2 Regular W VRTLS 450+ 12080 119.4" 4 4 4 4 4 100 3/4" 10872 90 4 4 4 4 3 Premium VRTLS 450+ 8039 119.4" 4 4 4 4 4 100 3/4" 7235 89 4 4 4 4 4 Diesel VRTLS 450+ 9248 119.4" 4 4 4 4 4 99 3/4" 8323 89 4 4 4 4 Saxon Usher UT-420 PEI/RP1200-12 pei.org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´1RµRU/LQHLV´<HVµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 02/29/2024 5 Clear VRTLS 450+ 8039 119.4" 4 4 4 4 4 100 3/4" 7235 89 4 4 4 4 Saxon Usher UT-420 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 1 Regular E VRTLS 450+ 13288 119.4" 4 4 4 4 100" 4 1" 4 4 2 Regular W VRTLS 450+ 12080 119.4" 4 4 4 4 100 3/4" 4 1" 4 4 3 Premium VRTLS 450+ 8039 119.4" 4 4 4 4 100 3/4" 4 1" 4 4 4 Diesel VRTLS 450+ 9248 119.4" 4 4 4 4 99 3/4" 4 2" 4 4 02/29/2024 Saxon Usher UT-420 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 10009668 5 Clear VRTLS 450+ 8039 119.4" 4 4 4 4 100 3/4" 4 2" 4 4 02/29/2024 Saxon Usher UT-420 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 02/29/2024 Reg 1 int Reg 4 lift 4 4 4 4 4 4 D/P/C int D/P/C 4 lift 4 4 4 4 4 4 Reg 1 stp Reg 4 4 4 4 4 4 4 4 Prm stp Prm 4 4 4 4 4 4 4 4 Clr stp Clr 4 4 4 4 4 4 4 4 Dsl stp Dsl 4 4 4 4 4 4 4 4 Reg 2 stp Reg 4 4 4 4 4 4 4 4 Saxon Usher UT-420 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 02/29/2024 Dsp 15/16 lines 4 4 4 4 4 4 4 4 Dsp 13/14 lines 4 4 4 4 4 4 4 4 Dsp 11/12 lines 4 4 4 4 4 4 4 4 Dsp 9/10 lines 4 4 4 4 4 4 4 4 Dsp 7/8 lines 4 4 4 4 4 4 4 4 Dsp 5/6 lines 4 4 4 4 4 4 4 4 Dsp 3/4 lines 4 4 4 4 4 4 4 4 Saxon Usher UT-420 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #670 1000968 02/29/2024 Dsp 1/2 lines 4 4 4 4 4 4 4 4 Saxon Usher UT-420 FORM 1 SUMMARY OF SOURCE TEST DATA SOURCE INFORMATION FACILITY PARAMETERS GDF Name and addresss GDF Representative and Title _________________________________ PHASE II SYSTEM TYPE (Check One) Balance ____ Hirt ____ Red Jacket ____ Hasstech ____ Healy ____Other GDF Phone No. (___)________________ Permit Conditions Source: GDF Vapor Recovery System GDF # A/C # Manifolded? Y or N Operating Parameters Number of Nozzles Served by Tank #1 ______ Number of Nozzles Served by Tank #3 ______ Number of Nozzles Served by Tank #2 ______ Number of Nozzles Served by Tank #4 ______ Applicable Regulations: VN Recommended Source Test Results and Comments Tank #: 1.Product Grade 2.Actual Tank Capacity, gallons 3.Gasoline Volume 4.Ullage, gallons (#2-#3) 5.Initial Pressure, inches H 2 O 6.Pressure After 1 Minute, inches H 2 O 7.Pressure After 2 Minutes, inches H 2 O 8.Pressure After 3 Minutes, inches H 2 O 9.Pressure After 4 Minutes, inches H 2 O 10.Final Pressure After 5 Minutes, inches H 2 O 11.Allowable Final Pressure Test Conducted by: Test Company: Date of Test: California Air Resources Board July 26, 2012 TP-201.3, Page 14 40CFR63CCCCCC Precision Testing Technologies Maverik #670 797 E 800 N Spanish Fork, UT VRS is Dual Point N/A 1 Reg1 13288 7627 5661 2.0 1.98 1.93 1.92 1.90 1.90 1.72 2 Reg2 12080 5411 6669 2.0 1.97 1.95 1.93 1.89 1.88 1.79 3 Prem 8039 2917 5122 2.0 1.95 1.93 1.90 1.89 1.87 1.72 5 Clear 8039 6186 1853 2.0 1.96 1.93 1.91 1.87 1.85 1.37 02/29/2024Saxon Usher UT-420 Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @ 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 2.5" to 6" wc <=0.05 cfh @ 2" wc MAVERIK #670 797 E 800 N Spanish Fork, UT 84660 02/29/2024 Regular 1 OPW 623V 4 0.03 4.02 0.15 7.14 Regular 2 OPW 623V 4 0.03 3.82 0.15 8.76 Premium OPW 623 V 4 0.02 3.06 0.12 7.17 Clear OPW 623V 4 0.03 4.15 0.18 7.5 Saxon Usher UT-420 California Air Resources Board October 8, 2003 TP-201.1B, Page 5 Form 1 Static Torque of Rotatable Phase I Adaptors Measurement Units: (Check Box): pound-inches pound-feet Vapor Adaptor 1 Vapor Adaptor 2 Vapor Adaptor 3 Vapor Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation:360 Rotation: 360 Rotation:360 Rotation: Product Adaptor 1 Product Adaptor 2 Product Adaptor 3 Product Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation: 360 Rotation: 360 Rotation:360 Rotation: Comments: ___________________________________________________________________ Test Company:Conducted By: Test Date:Facility Name: Facility Address:City: Precision Testing Technologies 02/29/2024 MAVERIK #670 797 E 800 N Spanish Fork, UT 84660 4 OPW 61VSA Regular 1 55 55 55 55 Yes OPW 61SALP Regular 1 70 70 70 70 Yes OPW 61VSA Regular 2 60 55 60 58.3 Yes OPW 61SALP Regular 2 85 85 85 85 Yes OPW 61VSA Premium 60 70 75 68.3 Yes OPW 61SALP Premium 90 90 90 90 Yes OPW 61VSA E-free 65 75 85 75 Yes OPW 61SALP E-free 65 75 75 71.6 Yes Saxon Usher UT-420