HomeMy WebLinkAboutDERR-2025-002398UTAH STATE FUEL NETWORK AST ANNUAL INSPECTION Facility Name and Site Address: Date: Facility ID # Purpose:Regular Reinspection Complaints Annual Inspection Nu m b e r Te s t e d Sa t i s f i e d Re j e c t e d A d v i s e Pumps Tested for Calibration Is tank grounding strap in good condition ? Is tank coating free of corrosion / damage ? Is tank free of noticable distortion, denting, buckeling ? Flanged connection bolts appear tight ? Normal and emergency vents appear in good condition ? Inspection Remarks: Technician signature Inspected By: Steven B. Martin UT121 Applied Environmental Services L.C. MONUMENT VALLEY HIGH SCHOOL 2-28-2025 5000159 X X INSTALLED NEW PV VALVE State Fuel Contact : Brett Gurney 385-602-4872 801-540 9258 Aesutah@aol.com Email: Brettgurney@utah.gov Fill and vapor connections in good condition ? ABOVEGROUND TANKS WITH ABOVEGROUND PRODUCT LINES Tank containment structure in satisfactory condition ? Free of tank settlement and foundation washout ? Tank supports in satisfactory condition ? Is water able to drain off tank pad and tank top ? Gasoline vent has P/V valve installed where required ? Valves / syphons / solenoids appear in good condition ? Spill containment visable and appears in good condition Electrical junction boxes and conduits in good condition Tank monitor free of active alarms ? Emergency shutoff installed ? Dispenser static test ? Tank overfill equipment installed ? Piping sumps appear in good condition ? COMMENTS / ACTION Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 14:15:39 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: MONUMENT VALLEY HIGH SCHOOL MONUMENT VALLEY, UTAH 5000159 AES UTAH TESTER # UT 0121 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 2-28-2025 1 DSL VED TLS 300C 10152 96 YES YES YES YES 81 YES 2.5 YES 2 R/UL VED TLS 300C 4073 61 YES YES YES YES 55 YES 1.5 YES PASS PASS BATTERY BACKUP FUNCTIONS PROPERLY ABOVEGROUND FUEL TANKS SETUP REPORT PRINTED Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 14:17:08 -07'00' Reason: I am the author of this document BILLING ADDRESS FACILITY ADDRESS WORK ORDER # DATE: CONTACT: DEQ ID# APPLIED ENVIRONMENTAL SERVICES, L.C. SEND PAYMENT TO : APPLIED ENVIRONMENTAL SERVICES ALL TESTS WERE PERFORMED IN A PROFESSIONAL MANNER, AND WITHIN COMMON PRACTICES OF THE INDUSTRY. DUE TO VARIABLES OF TIGHTNESS TESTING, THESE RESULTS CANNOT BE GUARANTEED. THERE ARE NO WARRANTIES. EXPRESSED, WRITTEN, OR IMPLIED. PO BOX 1073 BOUNTIFUL, UTAH 84011 . PO# 801-540-9258 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 MONUMENT VALLEY HIGH SCHOOL BRETT GURNEY 246107 5000159 / 1173 25014 2-28-2025 MONITOR CERTIFICATION 275.00 SITES SHARE OF TRAVEL 108 MI @ 2.00 216.00 INSTALLED NEW STATE SUPPLIED PV VALVE AND (ADAPTER ) ON UNLEADED VENT 1 HR @ 70.00 70.00 561.00TOTAL DUE: