Loading...
HomeMy WebLinkAboutDERR-2025-002319UTAH STATE FUEL NETWORK AST ANNUAL INSPECTION Facility Name and Site Address: Date: Facility ID # Purpose:Regular Reinspection Complaints Annual Inspection Nu m b e r Te s t e d Sa t i s f i e d Re j e c t e d A d v i s e Pumps Tested for Calibration Is tank grounding strap in good condition ? Is tank coating free of corrosion / damage ? Is tank free of noticable distortion, denting, buckeling ? Flanged connection bolts appear tight ? Normal and emergency vents appear in good condition ? Inspection Remarks: Technician signature Inspected By: Steven B. Martin UT121 Applied Environmental Services L.C. MONTEZUMA CREEK ELEMENTARY 2-27-2025 5000164 State Fuel Contact : Brett Gurney 385-602-4872 801-540 9258 Aesutah@aol.com Email: Brettgurney@utah.gov Fill and vapor connections in good condition ? AST WITH ABOVEGROUND PRODUCT LINES INSTALLED NEW PV VALVE ON UNLEADED VENT Tank containment structure in satisfactory condition ? Free of tank settlement and foundation washout ? Tank supports in satisfactory condition ? Is water able to drain off tank pad and tank top ? Gasoline vent has P/V valve installed where required ? Valves / syphons / solenoids appear in good condition ? Spill containment visable and appears in good condition Electrical junction boxes and conduits in good condition Tank monitor free of active alarms ? Emergency shutoff installed ? Dispenser static test ? Tank overfill equipment installed ? Piping sumps appear in good condition ? COMMENTS / ACTION Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 10:32:06 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: MONTEZUMA CREEK ELEMENTARY MONTEZUMA CREEK, UTAH 5000164 AES UTAH TESTER # UT 0121 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 2-27-2025 1 R/UL VED TLS 300C 4061 96 YES YES YES YES 81 YES 1.5 YES 2 DSL VED TLS 300C 6091 96 YES YES YES YES 81 YES 2.3 YES PASS PASS BATTERY BACKUP FUNCTIONS PROPERLY ABOVEGROUND STORAGE TANK SETUP REPORT PRINTED Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 10:33:37 -07'00' Reason: I am the author of this document BILLING ADDRESS FACILITY ADDRESS WORK ORDER # DATE: CONTACT: DEQ ID# APPLIED ENVIRONMENTAL SERVICES, L.C. SEND PAYMENT TO : APPLIED ENVIRONMENTAL SERVICES ALL TESTS WERE PERFORMED IN A PROFESSIONAL MANNER, AND WITHIN COMMON PRACTICES OF THE INDUSTRY. DUE TO VARIABLES OF TIGHTNESS TESTING, THESE RESULTS CANNOT BE GUARANTEED. THERE ARE NO WARRANTIES. EXPRESSED, WRITTEN, OR IMPLIED. PO BOX 1073 BOUNTIFUL, UTAH 84011 . PO# 801-540-9258 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 MONTEZUMA CREEK ELEMENTARY BRETT GURNEY 246107 5000164 / 1172 25011 2-27-2025 MONITOR CERTIFICATION 275.00 SITES SHARE OF TRAVEL 108 MI @ 2.00 216.00 INSTALLED STATE SUPPLIED OPW 623 PV VALVE ON UNLEADED VENT 1 HR @ 70.00 70.00 561.00TOTAL DUE: