HomeMy WebLinkAboutDAQ-2024-0071221
DAQC-PBR046160001-24
Site ID 4616 (B1)
MEMORANDUM
TO: FILE – UINTA WAX OPERATING, LLC – 5-31D-36 BTR
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager
FROM: Paul Bushman, Environmental Scientist
DATE: March 21, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: March 20, 2024
SOURCE LOCATION: 5-31D-36 BTR
Lat: 40.17812329 Long: -110.61268427
Business Office:
5128 Apache Plume Road, Suite 300
Fort Worth, TX 76109
SOURCE TYPE: Tank Battery
Duchesne County
API: 4301351146
SOURCE CONTACTS: Aimee Cole, Local Contact
Phone: 720-384-7365, Email: acole@finleyresources.com
Kaylene Bridwell, Corporate Environmental Contact
Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local gas
plant. The oil and process water in the storage tanks is loaded
into tanker trucks and hauled off site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart OOOO.
2
SOURCE EVALUATION: Site Type: PBR-Uncontrolled
Voluntarily controlled by flare
Site has Line Power
The source registered: 2,000 Estimated Oil BBL.
DOGM current 12 month rolling production is: 7,166 BBLs
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT:
8 Pneumatic Controllers
9 Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or
60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers
existing before 12/1/2015. [R307-502-4]
In Compliance. There are no continuous bleed natural gas-driven pneumatic controllers.
15 Oil and Gas Industry Registration Requirement
16 The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
17 Registration has been updated within 30 days of a company name change, removal or addition of
control devices, or termination of operations. [R307-505-3(3)]
In Compliance.
18 Storage Vessels
19 Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. Thief hatches were found closed and latched during the inspection.
23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. No modifications were observed during the inspection.
46 Visible Emissions
47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3]
In Compliance. No visible emissions were observed during the inspection.
3
55 Emission Inventory:
56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. An emissions inventory was submitted for the 2020 emissions inventory.
60 NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance. The source is below the 6 TPY PTE and is no longer an affected facility under
this part.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to 5-31D-36 BTR:
In Compliance – The source appears to be well maintained and
operated. The source was surveyed with an OGI camera and no
fugitive emissions were detected. The source is set up for
submerged loading, however the source is still equipped with the
capability for overhead loading from the storage tanks.
RECOMMENDATION FOR
NEXT INSPECTION: Inspect at the regular inspection frequency for this type of
source.
ATTACHMENTS: None.