Loading...
HomeMy WebLinkAboutDDW-2024-006983The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Allard Ranch Water Company Attn: Ralph Wing 3383 West Allard Ranch Drive Summit, UT 84772 Work Order: 23A1939 Project: 4th Qtr Replacement 2022 3/20/2023 Approved By: Dave Gayer, Laboratory Director 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 4 Certificate of Analysis 23A1939-01Lab Sample No.: Name: Sample Site: Sample Matrix: Sample Date: Receipt Date: Sampler: Allard Well Drinking Water Ralph Wing 1/27/2023 8:08 AM 1/30/2023 12:30 PM 4th Qtr Replacement 2022 Comments: PO Number: Project: Source Code:Sample Point:Report to State: System No.:UTAH11067 WS001 WS001 Y Allard Ranch Water Company Minimum Reporting LimitParameter Sample Result Units Analytical Method Analysis Date/Time Flag Preparation Date/Time EPA Max Contaminant Level (MCL) Radiochemistry Gross Alpha 1.4 SL-62pCi/L EPA 900.0 02/28/202302/28/2023156.3 ± 1.62 Gross Beta 1.9 SL-62pCi/L EPA 900.0 02/28/202302/28/2023 4.8 ± 1.62 Radium-226 0.34 SL-62pCi/L EPA 903.0 03/15/202303/10/202350.27 ± 0.316 Radium-228 0.57 SL-62pCi/L EPA 904.0 03/06/202303/06/202350.94 ± 0.33 Page 2 of 4 9632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 2 of 4 Certificate of Analysis Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit. 1 mg/L = one milligram per liter or 1 mg/Kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/Kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/Kg = one nanogram per kilogram = 1 part per trillion. Values reported in RED exceed Primary Drinking Water standards . Values reported in BLUE exceed Secondary Drinking Water standards . BLANK values in the MCL column indicate no standard. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Data Comparisons Flag Descriptions SL-62 = Analysis performed by Pace Analytical National , Mount Juliet, TN 37122 Page 3 of 4 9632 South 500 West Sandy, UT 84070801-262-7299 Office www.ChemtechFord.com Page 3 of 4 Page 4 of 4