HomeMy WebLinkAboutDSHW-2025-001630Site Information
Finalized Yes
Facility Name Integrated Water Management Landfill
Facility_ID SW0392
Facility Name Integrated Water Management Landfill
Street Address 20250 West 2000 South
City Duchesne
ZIP Code 84021
County Duchesne County
Inspection Date 07-10-2024
Type of Visit Routine Oversite
Is the Visit Announced?No
40.433171, -110.027615
Weather Conditions Sunny, high of 90 degrees Fahrenheit. Moderate winds.
Inspection Goal Facility surprise inspection in collaboration with EPA and DOGM.
Facility Contact Nate Robinson
Participants Nate Robinson (Manager)
Annette Maxwell (EPA)
Orlan Wallace (DOGM)
Bryan Watt (DWMRC)
Follow Up Inspection Needed?No
Recommended Follow Up Date
Depart Office Date 07-10-2024
Depart Office time 11:00 AM (-6 GMT)
Return to Office Date 07-10-2024
Return to Office time 06:00 PM (-6 GMT)
1. Pre-Inspection Review
1.1 Permit Review Yes
Comment Permit was reviewed prior to the inspection.
1.2 Annual Report Review No
Comment Annual report was not reviewed prior to the inspection.
1.3 Previous Inspection Review No
Comment Previous inspection report was not reviewed prior to the inspection.
1.4 Facility Contacts Confirmed Yes
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 1 of 7
Comment Facility contact confirmed as Nate Robinson.
1.5 Facility Contacted (If an
announced inspection)
No
Comment Surprise inspection was initiated by the EPA. DOGM and DWMRC
representatives were invited to attend and conduct facility inspections if
desired.
1.6 Local Health Contacted No
Comment Local health department was not contacted prior to the inspection.
1.7 Other N/A
Comment No additional comments at this time.
2. Facility / Operational Controls (1-Good, 5-Poor)
2.1 Litter 2
2.2 Roads 1
2.3 Gate House Operations 1
2.4 Vectors 1
2.5 Communications 1
2.6 Recycling Area NA
2.7 Fugitive Dust Control 1
2.8 Waste Inspection Area 1
2.9 Scavenging Control NA
2.10 Open Burning NA
2.11 Fences, Gates, Locks,
Access Control
1
2.12 Working Face 1
2.13 Daily - Soil NA
2.14 Daily - Alternative NA
2.15 Leachate Collection System 4
2.16 Other NA
Comment (Required)Some litter issues along fence line south of incinerator. Mostly used gloves,
rags, buckets, boxes, etc.
Landfill cell has been full of leachate and liquids for several years. IWM has
been gradually working at displacing the liquids with solids in the cell, but
most of the solids are being managed at the IWM Pinnacle Fuels Landfill.
Plans for continued displaced of leachate and other liquids was still in
progress. Nearly all new solid waste received at this facility came from the
incinerator waste.
3. Signs Required / Properly Posted
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 2 of 7
3.1 Operating Days / Hours Yes
3.2 Directions & Procedures Yes
3.3 Emergency Numbers Yes
3.4 List of Unacceptable Materials Yes
3.5 Other N/A
Comment (Required)Very good signage with clear communications and operators always on site.
4. Operator / Representative / Employees
4.1 On-site While Open Yes
4.2 Training Yes
4.3 Other N/A
Comment (Required)Operators are always onsite 24/7 for assistance due to high liquid volume
for the injection well coming in at all hours of the day and night.
5. Monitoring
5.1 Methane N/A
5.2 Random Inspections No
5.3 Leachate Yes
5.4 Ground Water Yes
5.5 Other N/A
Comment (Required)Did not see paperwork for random inspections. Leachate and groundwater
were monitored.
6. Drainage / Erosion
6.1 Water Run-on Yes
6.2 Water Run-off Yes
6.3 Other N/A
Comment (Required)Erosion control devices were in place, primarily in the form of gravel and
berms.
7. Proper Storage / Isolation / Disposal
7.1 Special Waste Yes
7.2 Batteries N/A
7.3 Hazardous Waste N/A
7.4 Infectious Waste N/A
7.6 Dead Animals N/A
7.7 Asbestos N/A
7.8 Bulky Waste N/A
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 3 of 7
7.9 Contaminated Soil N/A
7.10 Ash N/A
7.11 Sludge Yes
7.12 Other N/A
Comment (Required)Oil and gas waste and sludge derived from those wastes were controlled
through incineration, water displacement, mixing, and other mechanical
separation methods.
8. Cover
8.1 Intermediate Yes
8.2 Final N/A
8.3 Vegetation Yes
8.4 Other N/A
Comment (Required) Vegetation near old land farm (closed portion) was becoming well
established. This area was used as a deposition location for E&P waste
found in old landfill cells that were illegally operated before IWM took
ownership of the facility.
9. Inspection Records
9.1 Random Inspection Report N/A
9.2 Gas Monitoring System N/A
9.3 Surface Drainage Control N/A
9.4 Daily Records Yes
9.5 Weight or Volumes Yes
9.6 Intermediate Cover N/A
9.7 Final Cover N/A
9.8 Self Inspection (Quarterly
Reports)
N/A
9.9 Deviation From Plans Yes
9.10 Permit, Permit Application,
and Rules Available
Yes
9.11 Other N/A
Comment (Required)Daily records and permit was readily available. Inspector did not inquire
about other types of inspection records during this visit.
10. Monitoring / Sampling / Analysis Records
10.1 Explosive Gas Monitoring N/A
10.2 Leachate Sampling &
Treatment
Yes
10.3 Ground Water Sampling
Results
Yes
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 4 of 7
10.4 Other N/A
Comment (Required)Leachate and groundwater sampling has been conducted and analyzed for
constituents.
11. Special Waste Records
11.1 Lab Analysis Results Yes
11.2 Manifests Yes
11.3 Treatment Certification N/A
11.4 Paint Filter Test Results N/A
11.5 Onsite Treatment
Documentation
N/A
11.6 Other N/A
Comment (Required)Lab analysis results and waste manifests were available for inspector. Lab
analysis results were primary for leachate and landfill material analysis.
12. Waste Tires
12.1 Acceptance procedures for
Waste Tires
N/A
12.2 Waste Tire Pile Segregated N/A
12.3 Estimated Quanitity of Waste
Tires
No
Number of Tires
12.4 Waste Tire Fund Training N/A
Comment (Required)No waste tires are accepted at this facility.
13 Other Items
13.1 Notice of Inspections Form
Completed and Signed
N/A
13.2 N/A
13.3 N/A
13.4 N/A
Comment (Required)A notice of inspection form was not required for this inspection.
14. Special Permit Requirements
14.1 N/A
14.2 N/A
14.3 N/A
Comment (Required)No additional special permit requirements needed review at this time.
General Comments
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 5 of 7
Comments The facility has multiple permits for different agencies.
The only major issue under the Solid Waste Permit was the handling of high
liquids in the landfill cell. Liquids were running (channeling) out the side of
the landfill cell and into one of the overflow ponds. This was more of an
issue with their DOGM permit not allowing leachate from a landfill cell to
enter into an evaporation pond or surface impoundment. The new rules
were later approved under DWMRC Rules that this would be allowed once
surface impoundments used for evaporation transferred over to DWMRC.
However, during the time of the inspection this was not permitted by
DOGM.
DWMRC Inspector Signature
DWMRC Inspector Name Bryan Watt
Date/Time 07-10-2024
Photos
Attach Photos
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 6 of 7
Form Locations
Date Submitted: 03-13-2025 10:50 AM
Submitted By: bryanwatt@utah.gov
Solid Waste Program Facility Inspection Report Checklist
Page 7 of 7