HomeMy WebLinkAboutDERR-2024-005498Product Line Tightness Test Page 1 of 1 Work Order: 2365034 Date: 3/13/2024 Site Name/ID: 7-ELEVEN #34623 / 34623 Address: 2680 WEST 10400 SOUTH State ID 4002241 City: SOUTH JORDAN State: UT Zip: 84095 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 Regular RUL Pressure 50 13:41 14:41 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 TNK2 Premium PUL Pressure 50 13:41 14:41 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 TNK3 Diesel Low Sulfur Diesel Pressure 50 13:41 14:41 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: ut151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #34623 2680 WEST 10400 SOUTH State ID 4002241 SOUTH JORDAN UT 84095 34623 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 03/13/2024 RUL PUL Vaporless LD- 2000 Vaporless LD- 2000 Vaporless LD- 2000LD200LD2000LD2000 30 30 200 3 20 4 28 28 200 3 20 4 30 30 175 2 20 3 UT151 David Mathie NW1-2365034 Low Sulfur Diesel TTNK1 Regular:1 TTNK2 Premium:1 TTNK3 Diesel:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2365034 Date:3/13/2024 Site Name/ID:7-ELEVEN #34623 Address:2680 WEST 10400 SOUTH State ID 4002241 City:SOUTH JORDAN State:UT Zip:84095 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #34623 7-ELEVEN, INC. 2680 WEST 10400 SOUTH State ID 4002241 SOUTH JORDAN UT 84095 4002241 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 03/13/2024 1 2 3 RUL PUL DSL VR350 VR350 VR350 11849 11849 10369 119 119 119 UT151 David Mathie 2680 WEST 10400 SOUTH State ID 4002241 7-ELEVEN #34623 2680 WEST 10400 SOUTH State ID 4002241, SOUTH JORDAN, UT 8409534623 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS, TX 75221 972-828-7575 03/13/2024 ANNULAR ANNULAR ANNULAR STP STP STP RUL WET PUL WET DSL WET RUL PUL DSL UT151 David Mathie 7-ELEVEN #34623 2680 WEST 10400 SOUTH State ID 4002241SOUTH JORDAN , UT 84095 4002241 Tanknology, Inc. 7-ELEVEN, INC. 972-828-7575 03/13/2024 P.O. BOX 711 DALLAS, TX 75221 1 RUL 5 OPW 2 PUL 5 OPW 3 DSL 5 OPW 14.5 1329 14.5 1429 1 HR 0 14.5 1326 14.5 1326 1 HR 0 30 WC 1322 30 WC 1323 1 MIN 0 UT151 David Mathie PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.06 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -0.08 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.66 Pass Neg Leak Rate (CFH)0.21 17 0.0360 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.83 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 0.00 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 0.00 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 8 0.0170 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.54 Pass Neg Leak Rate (CFH)0.21 18 0.0382 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -6.76 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0297 Total -ve LR: 0.0742 Test Date 3/13/2024 Technician Name David Mathie WO #2365034 Facility Name / Loc #7-ELEVEN #34623 34623 Street 2680 WEST 10400 SOUTH State ID 4002241 City, St, Zip SOUTH JORDAN, UT 84095 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2365034 Site ID / Name:34623 / 7-ELEVEN #34623 Address:2680 WEST 10400 SOUTH State ID 4002241 City:SOUTH JORDAN State:UT Zip:84095